cpqRackServerTempSensorType
CPQRACK-MIB ·
.1.3.6.1.4.1.232.22.2.4.3.1.1.11
Object
column
optional
Enumeration
This specifies the type of this instance of temperature
sensor.
This value will be one of the following:
other(1)
Temperature threshold type could not be determined.
blowout(5)
If a blowout(5) temperature sensor reaches its threshold,
the fan or fans in the area of the temperature sensor will
increase in speed in an attempt to reduce the temperature
before a caution or critical threshold is reached.
caution(9)
If a caution(9) temperature sensor reaches its threshold, the
cpqRackServerTempSensorCondition will be set to degraded(3)
and the system will either continue or shutdown depending
on the local blade server policy settings.
critical(15)
If a critical(15) temperature sensor reaches its threshold,
cpqRackServerTempSensorCondition will be set to failed(4)
and the blade server will shutdown.
Context
- MIB
- CPQRACK-MIB
- OID
.1.3.6.1.4.1.232.22.2.4.3.1.1.11- Type
- column
- Access
- readonly
- Status
- optional
- Parent
- cpqRackServerTempSensorEntry
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | other |
5 | blowout |
9 | caution |
15 | critical |