ve status has been set to degraded.
User Action: The drive should be scheduled for replacement.
Refer to the appropriate Maintenance and Service Guide for
detailed information on a component replacement.
cpqIdeDriveOk
.1.3.6.1.4.1.232.0.14002
ve status has been set to ok.
User Action: None.
cpqIdeDriveUltraAtaDegraded
.1.3.6.1.4.1.232.0.14003
ve detects an excessive number of Ultra ATA
data transmission errors between the hard drive and the
processor.
User Action: For best performance move Ultra ATA devices to the
primary controller and non Ultra ATA devices to the secondary
controller. If errors still persist, consider replacing the
standard 40-conductor IDE cable with an 80-conductor Ultra ATA
cable.
cpqIdeAtaDiskStatusChange
.1.3.6.1.4.1.232.0.14004
tatus Change.
This trap signifies that the agent has detected a change in the
status of an ATA disk drive. The variable cpqIdeAtaDiskStatus
indicates the current disk drive status.
User Action: If cpqIdeAtaDiskStatus is `smartError(3)`,
`failed(4)` or `ssdWearOut(5)` replace the drive.
cpqIdeLogicalDriveStatusChange
.1.3.6.1.4.1.232.0.14005
l Drive Status Change.
This trap signifies that the agent has detected a change in the
status of an IDE logical drive. The variable
cpqIdeLogicalDriveStatus indicates the current logical drive
status.
User Action: If the logical drive status is failed(5), examine
the array for failed drives that need replacement.
cpqIdeAtaDiskSSDWearStatusChange
.1.3.6.1.4.1.232.0.14006
e Disk Wear Status Change.
This trap signifies that the agent has detected a change in the
SSD wear status of a SATA physical drive. The variable
cpqIdeAtaDiskSSDWearStatus indicates the current SSD wear status.
User Action: If cpqIdeAtaDiskSSDWearStatus is `ssdWearOut(6)`,
replace the drive.
cpqIdeAtaSecureEraseFailed
.1.3.6.1.4.1.232.0.14007
Secure Erase of SATA drive has failed.
cpqIdeAtaDiskStatusChange2
.1.3.6.1.4.1.232.0.14008
tatus Change (with Location).
This trap signifies that the agent has detected a change in the
status of an ATA disk drive. The variable cpqIdeAtaDiskStatus
indicates the current disk drive status.
User Action: If cpqIdeAtaDiskStatus is `smartError(3)`,
`failed(4)` or `ssdWearOut(5)` replace the drive.
cpqIdeAtaDiskSSDWearStatusChange2
.1.3.6.1.4.1.232.0.14009
e Disk Wear Status Change (with Location).
This trap signifies that the agent has detected a change in the
SSD wear status of a SATA physical drive. The variable
cpqIdeAtaDiskSSDWearStatus indicates the current SSD wear status.
User Action: If cpqIdeAtaDiskSSDWearStatus is `ssdWearOut(6)`,
replace the drive.