cpqIdeAtaDiskSSDPercntEndrnceUsed
CPQIDE-MIB ·
.1.3.6.1.4.1.232.14.2.4.1.1.21
Object
SATA Physical Drive Solid State Percent Endurance Used.
This value specifies the hundredths of the percentage of solid state
disk life used. The value of this field is allowed to exceed 100%.
As an example, if the value reported is 50, this would indicate .50
percent endurance used.
This value will be 4,294,967,295 if the percent endurance used cannot
be determined or is not supported.
Context
- MIB
- CPQIDE-MIB
- OID
.1.3.6.1.4.1.232.14.2.4.1.1.21- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- cpqIdeAtaDiskEntry
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQIDE-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQIDE-MIB::cpqIdeAtaDiskSSDPercntEndrnceUsed'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CPQIDE-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQIDE-MIB::cpqIdeAtaDiskSSDPercntEndrnceUsed.<cpqIdeAtaDiskControllerIndex>.<cpqIdeAtaDiskIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CPQIDE-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CPQIDE-MIB::cpqIdeAtaDiskSSDPercntEndrnceUsed'
Syntax
- Source
- RFC1155-SMIGauge
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295