CISCO-OPTICAL-MONITOR-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
4
Rows
4
Columns
37
.1.3.6.1.4.1.9.9.264.1.1.1 · 1 row entry · 19 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cOpticalMonTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-OPTICAL-MONITOR-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-OPTICAL-MONITOR-MIB::cOpticalMonTable'
This table provides objects to monitor optical
parameters in a network element. It also provides
objects for setting high and low threshold levels, with
configurable severities, on these monitored parameters.
cOpticalMonEntry row .1.3.6.1.4.1.9.9.264.1.1.1.1
An entry in the cOpticalMonTable provides objects to
monitor an optical parameter and set threshold levels
on that parameter, at an optical interface.

Note that the set of monitored optical parameters may v…
Column Syntax OID
This object indicates the direction monitored for the
optical interface, in this entry.
OpticalIfDirection
Type Values:
1receive
2transmit
3notApplicable
.1.3.6.1.4.1.9.9.264.1.1.1.1.1
This object indicates whether the optical characteristics are
measured before or after adjustment (e.g. optical amplification
or attenuation), at this interface.
OpticalIfMonLocation
Type Values:
1beforeAdjustment
2afterAdjustment
3notApplicable
.1.3.6.1.4.1.9.9.264.1.1.1.1.2
This object specifies the optical parameter that is being
monitored in this entry.
OpticalParameterType
Type Values:
1power
2acPower
3ambientTemp
4laserTemp
5biasCurrent
6peltierCurrent
7xcvrVoltage
.1.3.6.1.4.1.9.9.264.1.1.1.1.3
This object gives the value measured for the particular
optical parameter specified by the cOpticalMonParameterType
object.
OpticalParameterValue
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.9.9.264.1.1.1.1.4
This object is used to set a high alarm threshold on the
optical parameter being monitored.

An alarm condition will be raised if the value given by
cOpticalParameterValue goes from below the value configu…
OpticalParameterValuer/w
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.9.9.264.1.1.1.1.5
This object is used to specify a severity level associated
with the high alarm threshold given by the
cOpticalParamHighAlarmThresh object. The values 'notAlarmed',
'notReported', and 'cleared' do not apply.
OpticalAlarmSeverityr/w
Type Values:
1critical
2major
3minor
4notAlarmed
5notReported
6cleared
.1.3.6.1.4.1.9.9.264.1.1.1.1.6
This object is used to set a high warning threshold on
the optical parameter being monitored.

A threshold crossing condition will be indicated if the value
given by cOpticalParameterValue goes from below …
OpticalParameterValuer/w
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.9.9.264.1.1.1.1.7
This object is used to specify a severity level associated
with the high warning threshold given by the
cOpticalParamHighWarningThresh object. The values 'critical',
'major', and 'cleared' do not apply.

T…
OpticalAlarmSeverityr/w
Type Values:
1critical
2major
3minor
4notAlarmed
5notReported
6cleared
.1.3.6.1.4.1.9.9.264.1.1.1.1.8
This object is used to set a low alarm threshold on the
optical parameter being monitored.

An alarm condition will be raised if the value given by
cOpticalParameterValue goes from above the value configur…
OpticalParameterValuer/w
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.9.9.264.1.1.1.1.9
This object is used to specify a severity level associated
with the low alarm threshold given by the
cOpticalParamLowAlarmThresh object. The values 'notAlarmed',
'notReported', and 'cleared' do not apply.
OpticalAlarmSeverityr/w
Type Values:
1critical
2major
3minor
4notAlarmed
5notReported
6cleared
.1.3.6.1.4.1.9.9.264.1.1.1.1.10
This object is used to set a low warning threshold on
the optical parameter being monitored.

A threshold crossing condition will be indicated if the value
given by cOpticalParameterValue goes from above t…
OpticalParameterValuer/w
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.9.9.264.1.1.1.1.11
This object is used to specify a severity level associated
with the low warning threshold given by the
cOpticalParamLowWarningThresh object. The values 'critical',
'major', and 'cleared' do not apply.

The…
OpticalAlarmSeverityr/w
Type Values:
1critical
2major
3minor
4notAlarmed
5notReported
6cleared
.1.3.6.1.4.1.9.9.264.1.1.1.1.12
This object is used to indicate the current status of
the thresholds for the monitored optical parameter
on the interface.

If a threshold is currently being exceeded on the
interface, the corresponding bi…
OpticalAlarmStatus
Type Constraints:
range: 1
.1.3.6.1.4.1.9.9.264.1.1.1.1.13
This object indicates the threshold value of the highest
severity threshold that is currently being exceeded
on the interface, for the optical parameter.
If no threshold value is currently being
exceeded, then the value…
OpticalParameterValue
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.9.9.264.1.1.1.1.14
This object indicates the maximum severity of any thresholds
that are currently being exceeded on the interface, for the
optical parameter.
OpticalAlarmSeverity
Type Values:
1critical
2major
3minor
4notAlarmed
5notReported
6cleared
.1.3.6.1.4.1.9.9.264.1.1.1.1.15
This object specifies the value of sysUpTime at the last time
a threshold related to a particular optical parameter was
exceeded or cleared on the interface.
SNMPv2-TCTimeStamp
Based On: SNMPv2-SMITimeTicks
Description:
The value of the sysUpTime object at which a specific
occurrence happened. The specific occurrence must be

defined in the description of any object defined using this
type.

If sysUpTime is reset t…
.1.3.6.1.4.1.9.9.264.1.1.1.1.16
This object gives the number of previous 15 minute
intervals for which valid performance monitoring data
has been stored on the interface.

The value of this object will be n (where n is the maximum
number…
Unsigned32
Constraints:
range: 0-96
.1.3.6.1.4.1.9.9.264.1.1.1.1.17
This object gives the number of previous 24 hour
intervals for which valid performance monitoring data
has been stored on the interface.

The value of this object will be 0 if the measurement
was (re-)star…
Unsigned32
Constraints:
range: 0-1
.1.3.6.1.4.1.9.9.264.1.1.1.1.18
This object indicates if the current value of a particular
threshold in this entry is user configured value or it is
a system default value. It also allows user to specify
the list of thresholds for this entry which s…
Bitsr/w
Enumerated Values:
0highAlarmDefThresh
1highWarnDefThresh
2lowAlarmDefThresh
3lowWarnDefThresh
.1.3.6.1.4.1.9.9.264.1.1.1.1.19
.1.3.6.1.4.1.9.9.264.1.1.5 · 1 row entry · 1 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cOpticalMonIfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-OPTICAL-MONITOR-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-OPTICAL-MONITOR-MIB::cOpticalMonIfTable'
This table contains the list of optical interfaces
populated in cOpticalMonTable.
cOpticalMonIfEntry row .1.3.6.1.4.1.9.9.264.1.1.5.1
An entry containing the information for a particular optical interface.
Indexes
Column Syntax OID
This object indicates when this optical transceiver was detected by the
system.
secondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.264.1.1.5.1.1
.1.3.6.1.4.1.9.9.264.1.2.1 · 1 row entry · 8 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cOpticalPMCurrentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-OPTICAL-MONITOR-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-OPTICAL-MONITOR-MIB::cOpticalPMCurrentTable'
This table contains performance monitoring data for the
various optical parameters, collected over the current 15
minute or the current 24 hour interval.
cOpticalPMCurrentEntry row .1.3.6.1.4.1.9.9.264.1.2.1.1
An entry in the cOpticalPMCurrentTable. It contains
performance monitoring data for a monitored optical
parameter at an interface, collected over the current 15
minute or the current 24 hour interval.

Note …
Column Syntax OID
This object indicates whether the optical parameter values
given in this entry are collected over the current 15 minute or
the current 24 hour interval.
OpticalPMPeriod
Type Values:
1fifteenMin
2twentyFourHour
.1.3.6.1.4.1.9.9.264.1.2.1.1.1
This object indicates the direction monitored for the optical
interface, in this entry.
OpticalIfDirection
Type Values:
1receive
2transmit
3notApplicable
.1.3.6.1.4.1.9.9.264.1.2.1.1.2
This object indicates whether the optical characteristics are
measured before or after adjustment (e.g. optical amplification
or attenuation), at this interface.
OpticalIfMonLocation
Type Values:
1beforeAdjustment
2afterAdjustment
3notApplicable
.1.3.6.1.4.1.9.9.264.1.2.1.1.3
This object specifies the optical parameter that is being
monitored, in this entry.
OpticalParameterType
Type Values:
1power
2acPower
3ambientTemp
4laserTemp
5biasCurrent
6peltierCurrent
7xcvrVoltage
.1.3.6.1.4.1.9.9.264.1.2.1.1.4
This object gives the maximum value measured for the monitored
optical parameter, in the current 15 minute or the current
24 hour interval.
OpticalParameterValue
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.9.9.264.1.2.1.1.5
This object gives the minimum value measured for the monitored
optical parameter, in the current 15 minute or the current
24 hour interval.
OpticalParameterValue
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.9.9.264.1.2.1.1.6
This object gives the average value of the monitored
optical parameter, in the current 15 minute or the current
24 hour interval.
OpticalParameterValue
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.9.9.264.1.2.1.1.7
This object is used to indicate the number of seconds,
in the current 15 minute or the current 24 hour interval, for
which the optical performance data is not accounted for.

In the receive direction, the …
Integer32
Constraints:
range: 0-86400
.1.3.6.1.4.1.9.9.264.1.2.1.1.8
.1.3.6.1.4.1.9.9.264.1.2.2 · 1 row entry · 9 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cOpticalPMIntervalTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-OPTICAL-MONITOR-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-OPTICAL-MONITOR-MIB::cOpticalPMIntervalTable'
This table stores performance monitoring data for the
various optical parameters, collected over previous
intervals.
          
This table can have entries for one complete 24 hour
interval and up to 96 complete 15 minute
intervals. A system is required to store at least
4 completed 15 minute intervals. The number of valid
15 minute intervals in this table is indicated by the
cOpticalMon15MinValidIntervals object and the number of
valid 24 hour intervals is indicated by the
cOpticalMon24HrValidIntervals object.
cOpticalPMIntervalEntry row .1.3.6.1.4.1.9.9.264.1.2.2.1
An entry in the cOpticalPMIntervalTable. It contains
performance monitoring data for an optical parameter,
collected over a previous interval.

Note that the set of monitored optical parameters may vary
base…
Column Syntax OID
This object indicates whether the optical parameter values,
given in this entry, are collected over a period of 15 minutes
or 24 hours.
OpticalPMPeriod
Type Values:
1fifteenMin
2twentyFourHour
.1.3.6.1.4.1.9.9.264.1.2.2.1.1
A number between 1 and 96, which identifies the
interval for which the set of optical parameter values is
available. The interval identified by 1 is the most recently
completed 15 minute or 24 hour interval, and the int…
Integer32
Constraints:
range: 1-96
.1.3.6.1.4.1.9.9.264.1.2.2.1.2
This object indicates the direction monitored for the optical
interface, in this entry.
OpticalIfDirection
Type Values:
1receive
2transmit
3notApplicable
.1.3.6.1.4.1.9.9.264.1.2.2.1.3
This object indicates whether the optical characteristics
are measured before or after adjustment (e.g.
optical amplification or attenuation), at this interface.
OpticalIfMonLocation
Type Values:
1beforeAdjustment
2afterAdjustment
3notApplicable
.1.3.6.1.4.1.9.9.264.1.2.2.1.4
This object specifies the optical parameter that is being
monitored, in this entry.
OpticalParameterType
Type Values:
1power
2acPower
3ambientTemp
4laserTemp
5biasCurrent
6peltierCurrent
7xcvrVoltage
.1.3.6.1.4.1.9.9.264.1.2.2.1.5
This object gives the maximum value measured for the optical
parameter, in a particular 15 minute or 24 hour interval.
OpticalParameterValue
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.9.9.264.1.2.2.1.6
This object gives the minimum value measured for the optical
parameter, in a particular 15 minute or 24 hour interval.
OpticalParameterValue
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.9.9.264.1.2.2.1.7
This object gives the average value of the measured optical
parameter, in a particular 15 minute or 24 hour interval.
OpticalParameterValue
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.9.9.264.1.2.2.1.8
This object is used to indicate the number of seconds,
in the particular 15 minute or 24 hour interval, for which the
optical performance data is not accounted for.

In the receive direction, the performan…
Integer32
Constraints:
range: 0-86400
.1.3.6.1.4.1.9.9.264.1.2.2.1.9