CISCO-ENTITY-FRU-CONTROL-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
17
Rows
17
Columns
54
.1.3.6.1.4.1.9.9.117.1.1.1 · 1 row entry · 7 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cefcFRUPowerSupplyGroupTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-ENTITY-FRU-CONTROL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-ENTITY-FRU-CONTROL-MIB::cefcFRUPowerSupplyGroupTable'
This table lists the redundancy mode and the
operational status of the power supply groups
in the system.
cefcFRUPowerSupplyGroupEntry row .1.3.6.1.4.1.9.9.117.1.1.1.1
An cefcFRUPowerSupplyGroupTable entry lists the desired
redundancy mode, the units of the power outputs and the
available and drawn current for the power supply group.

Entries are created by the agent when…
Column Syntax OID
The administratively desired power supply redundancy
mode.
PowerRedundancyTyper/w
Type Values:
1notsupported
2redundant
3combined
4nonRedundant
5psRedundant
6inPwrSrcRedundant
7psRedundantSingleInput
.1.3.6.1.4.1.9.9.117.1.1.1.1.1
The units of primary supply to interpret
cefcTotalAvailableCurrent and cefcTotalDrawnCurrent
as power.

For example, one 1000-watt power supply could
deliver 100 amperes at 10 volts DC. So the value
of c…
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.9.9.117.1.1.1.1.2
Total current available for FRU usage.
FRUCurrentType
Type Constraints:
range: -1000000000..1000000000
.1.3.6.1.4.1.9.9.117.1.1.1.1.3
Total current drawn by powered-on FRUs.
FRUCurrentType
Type Constraints:
range: -1000000000..1000000000
.1.3.6.1.4.1.9.9.117.1.1.1.1.4
The power supply redundancy operational mode.
PowerRedundancyType
Type Values:
1notsupported
2redundant
3combined
4nonRedundant
5psRedundant
6inPwrSrcRedundant
7psRedundantSingleInput
.1.3.6.1.4.1.9.9.117.1.1.1.1.5
This object has the value of notApplicable(1) when
cefcPowerRedundancyOperMode of the instance does not
have the value of nonRedundant(4).

The other values explain the reason why
cefcPowerRedundancyOperM…
Enumeration
Enumerated Values:
1notApplicable
2unknown
3singleSupply
4mismatchedSupplies
5supplyError
.1.3.6.1.4.1.9.9.117.1.1.1.1.6
Total inline current drawn for inline operation.
FRUCurrentType
Type Constraints:
range: -1000000000..1000000000
.1.3.6.1.4.1.9.9.117.1.1.1.1.7
.1.3.6.1.4.1.9.9.117.1.1.2 · 1 row entry · 5 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cefcFRUPowerStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-ENTITY-FRU-CONTROL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-ENTITY-FRU-CONTROL-MIB::cefcFRUPowerStatusTable'
This table lists the power-related administrative status
and operational status of the manageable components
in the system.
cefcFRUPowerStatusEntry row .1.3.6.1.4.1.9.9.117.1.1.2.1
An cefcFRUPowerStatusTable entry lists the desired
administrative status, the operational status of the
power manageable component, and the current required by
the component for operation.

Entries are cre…
Column Syntax OID
Administratively desired FRU power state.
PowerAdminTyper/w
Type Values:
1on
2off
3inlineAuto
4inlineOn
5powerCycle
.1.3.6.1.4.1.9.9.117.1.1.2.1.1
Operational FRU power state.
PowerOperType
Type Values:
1offEnvOther
2on
3offAdmin
4offDenied
5offEnvPower
6offEnvTemp
7offEnvFan
8failed
9onButFanFail
10offCooling
11offConnectorRating
12onButInlinePowerFail
.1.3.6.1.4.1.9.9.117.1.1.2.1.2
Current supplied by the FRU (positive values)
or current required to operate the FRU (negative values).
FRUCurrentType
Type Constraints:
range: -1000000000..1000000000
.1.3.6.1.4.1.9.9.117.1.1.2.1.3
This object indicates the set of supported power capabilities
of the FRU.

realTimeCurrent(0) -
cefcFRURealTimeCurrent is supported by the FRU.
Bits
Enumerated Values:
0realTimeCurrent
.1.3.6.1.4.1.9.9.117.1.1.2.1.4
This object indicates the realtime value of current supplied
by the FRU (positive values) or the realtime value of current
drawn by the FRU (negative values).
FRUCurrentType
Type Constraints:
range: -1000000000..1000000000
.1.3.6.1.4.1.9.9.117.1.1.2.1.5
.1.3.6.1.4.1.9.9.117.1.1.4 · 1 row entry · 6 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cefcFRUPowerSupplyValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-ENTITY-FRU-CONTROL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-ENTITY-FRU-CONTROL-MIB::cefcFRUPowerSupplyValueTable'
This table lists the power capacity of a power FRU in the
system if it provides variable power. Power supplies usually
provide either system or inline power. They cannot be 
controlled by software to dictate how they distribute power.
We can also have what are known as variable power supplies.
They can provide both system and inline power and can be 
varied within hardware defined ranges for system and inline
limited by a total maximum combined output. They could be
configured by the user via CLI or SNMP or be controlled by
software internally.
This table supplements the information in the
cefcFRUPowerStatusTable for power supply FRUs. The 
cefcFRUCurrent attribute in that table provides the overall
current the power supply FRU can provide while this table 
gives us the individual contribution towards system and 
inline power.
cefcFRUPowerSupplyValueEntry row .1.3.6.1.4.1.9.9.117.1.1.4.1
An cefcFRUPowerSupplyValueTable entry lists the current
provided by the FRU for operation.

Entries are created by the agent at system power-up or
FRU insertion. Entries are deleted by the agent at FRU
rem…
Column Syntax OID
Total current that could be supplied by the FRU (positive
values) for system operations.
FRUCurrentTyper/w
Type Constraints:
range: -1000000000..1000000000
.1.3.6.1.4.1.9.9.117.1.1.4.1.1
Amount of current drawn by the FRU's in the system towards
system operations from this FRU
FRUCurrentTyper/w
Type Constraints:
range: -1000000000..1000000000
.1.3.6.1.4.1.9.9.117.1.1.4.1.2
Total current supplied by the FRU (positive values) for
inline operations.
FRUCurrentTyper/w
Type Constraints:
range: -1000000000..1000000000
.1.3.6.1.4.1.9.9.117.1.1.4.1.3
Amount of current that is being drawn from this FRU for inline
operation.
FRUCurrentTyper/w
Type Constraints:
range: -1000000000..1000000000
.1.3.6.1.4.1.9.9.117.1.1.4.1.4
Amount of actual input current of this power supply.
FRUCurrentType
Type Constraints:
range: -1000000000..1000000000
.1.3.6.1.4.1.9.9.117.1.1.4.1.5
Amount of actual output current of this power supply.
FRUCurrentType
Type Constraints:
range: -1000000000..1000000000
.1.3.6.1.4.1.9.9.117.1.1.4.1.6
.1.3.6.1.4.1.9.9.117.1.2.1 · 1 row entry · 10 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cefcModuleTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-ENTITY-FRU-CONTROL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-ENTITY-FRU-CONTROL-MIB::cefcModuleTable'
A cefcModuleTable entry lists the operational and
administrative status information for ENTITY-MIB
entPhysicalTable entries for manageable components
of type PhysicalClass module(9).
cefcModuleEntry row .1.3.6.1.4.1.9.9.117.1.2.1.1
A cefcModuleStatusTable entry lists the operational and
administrative status information for ENTITY-MIB
entPhysicalTable entries for manageable components
of type PhysicalClass module(9).

Entries are crea…
Column Syntax OID
This object provides administrative control of the
module.
ModuleAdminTyper/w
Type Values:
1enabled
2disabled
3reset
4outOfServiceAdmin
.1.3.6.1.4.1.9.9.117.1.2.1.1.1
This object shows the module's operational state.
ModuleOperType
Type Values:
1unknown
2ok
3disabled
4okButDiagFailed
5boot
6selfTest
7failed
8missing
9mismatchWithParent
10mismatchConfig
11diagFailed
12dormant
13outOfServiceAdmin
14outOfServiceEnvTemp
15poweredDown
16poweredUp
17powerDenied
18powerCycled
19okButPowerOverWarning
20okButPowerOverCritical
21syncInProgress
22upgrading
23okButAuthFailed
24mdr
25fwMismatchFound
26fwDownloadSuccess
27fwDownloadFailure
.1.3.6.1.4.1.9.9.117.1.2.1.1.2
This object identifies the reason for the last reset performed
on the module.
ModuleResetReasonType
Type Values:
1unknown
2powerUp
3parityError
4clearConfigReset
5manualReset
6watchDogTimeoutReset
7resourceOverflowReset
8missingTaskReset
9lowVoltageReset
10controllerReset
11systemReset
12switchoverReset
13upgradeReset
14downgradeReset
15cacheErrorReset
16deviceDriverReset
17softwareExceptionReset
18restoreConfigReset
19abortRevReset
20burnBootReset
21standbyCdHealthierReset
22nonNativeConfigClearReset
23memoryProtectionErrorReset
.1.3.6.1.4.1.9.9.117.1.2.1.1.3
The value of sysUpTime at the time the cefcModuleOperStatus
is changed.
SNMPv2-TCTimeStamp
Based On: SNMPv2-SMITimeTicks
Description:
The value of the sysUpTime object at which a specific
occurrence happened. The specific occurrence must be

defined in the description of any object defined using this
type.

If sysUpTime is reset t…
.1.3.6.1.4.1.9.9.117.1.2.1.1.4
The value of sysUpTime when the
configuration was most recently cleared.
SNMPv2-TCTimeStamp
Based On: SNMPv2-SMITimeTicks
Description:
The value of the sysUpTime object at which a specific
occurrence happened. The specific occurrence must be

defined in the description of any object defined using this
type.

If sysUpTime is reset t…
.1.3.6.1.4.1.9.9.117.1.2.1.1.5
A description qualifying the module reset reason
specified in cefcModuleResetReason.

Examples:
command xyz
missing task
switch over
watchdog timeout
etc.

cefcMo…
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.9.9.117.1.2.1.1.6
This object displays human-readable textual string which
describes the cause of the last state change of the
module. This object contains zero length string
if no meaningful reason could be provided.

Exam…
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.9.9.117.1.2.1.1.7
This object provides the up time for the module
since it was last re-initialized.

This object is not persistent; if a module reset,
restart, power off, the up time starts from zero.
FRUTimeSeconds .1.3.6.1.4.1.9.9.117.1.2.1.1.8
This object indicates the VM module's operational state.
CefcVmModuleOperType
Type Values:
1down
2up
3unknown
4goingDown
.1.3.6.1.4.1.9.9.117.1.2.1.1.9
The value of sysUpTime at the time the cefcVmModuleOperStatus
is changed.
SNMPv2-TCTimeStamp
Based On: SNMPv2-SMITimeTicks
Description:
The value of the sysUpTime object at which a specific
occurrence happened. The specific occurrence must be

defined in the description of any object defined using this
type.

If sysUpTime is reset t…
.1.3.6.1.4.1.9.9.117.1.2.1.1.10
.1.3.6.1.4.1.9.9.117.1.2.2 · 1 row entry · 2 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cefcIntelliModuleTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-ENTITY-FRU-CONTROL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-ENTITY-FRU-CONTROL-MIB::cefcIntelliModuleTable'
This table sparsely augments the
cefcModuleTable (i.e., every row in
this table corresponds to a row in
the cefcModuleTable but not necessarily
vice-versa).
          
A cefcIntelliModuleTable entry lists the
information specific to intelligent
modules which cannot be provided by the
cefcModuleTable.
cefcIntelliModuleEntry row .1.3.6.1.4.1.9.9.117.1.2.2.1
A cefcIntelliModuleTable entry lists the
information specific to an intelligent
module which cannot be provided by
this module's corresponding instance in
the cefcModuleTable. Only an intelligent
module with Internet ad…
Column Syntax OID
The type of Internet address by which the
intelligent module is reachable.
INET-ADDRESS-MIBInetAddressType
Type Values:
0unknown
1ipv4
2ipv6
3ipv4z
4ipv6z
16dns
25l2vpn
.1.3.6.1.4.1.9.9.117.1.2.2.1.1
The Internet address configured
for the intelligent module.
The type of this address is
determined by the value of the object
cefcIntelliModuleIPAddrType.
INET-ADDRESS-MIBInetAddress
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.117.1.2.2.1.2
.1.3.6.1.4.1.9.9.117.1.2.3 · 1 row entry · 1 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cefcModuleLocalSwitchingTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-ENTITY-FRU-CONTROL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-ENTITY-FRU-CONTROL-MIB::cefcModuleLocalSwitchingTable'
This table sparsely augments the cefcModuleTable
(i.e., every row in this table corresponds to a row in
the cefcModuleTable but not necessarily vice-versa).
          
A cefcModuleLocalSwitchingTable entry lists the
information specific to local switching capable
modules which cannot be provided by the
cefcModuleTable.
cefcModuleLocalSwitchingEntry row .1.3.6.1.4.1.9.9.117.1.2.3.1
A cefcModuleLocalSwitchingTable entry lists the
information specific to a local switching capable
module which cannot be provided by this module's
corresponding instance in the cefcModuleTable.
Only a module which is ca…
Column Syntax OID
This object specifies the mode of local switching.

enabled(1) - local switching is enabled.
disabled(2) - local switching is disabled.
Enumerationr/w
Enumerated Values:
1enabled
2disabled
.1.3.6.1.4.1.9.9.117.1.2.3.1.1
.1.3.6.1.4.1.9.9.117.1.4.1 · 1 row entry · 2 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cefcFanTrayStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-ENTITY-FRU-CONTROL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-ENTITY-FRU-CONTROL-MIB::cefcFanTrayStatusTable'
This table contains the operational status information
for all ENTITY-MIB entPhysicalTable entries which have 
an entPhysicalClass of 'fan'; specifically, all  
entPhysicalTable entries which represent either: one 
physical fan, or a single physical 'fan tray' which is a
manufactured (inseparable in the field) combination of 
multiple fans.
cefcFanTrayStatusEntry row .1.3.6.1.4.1.9.9.117.1.4.1.1
An cefcFanTrayStatusTable entry lists the operational
status information for the ENTITY-MIB entPhysicalTable
entry which is identified by the value of entPhysicalIndex.
The value of entPhysicalClass for the identified …
Column Syntax OID
The operational state of the fan or fan tray.
unknown(1) - unknown.
up(2) - powered on.
down(3) - powered down.
warning(4) - partial failure, needs replacement
as soon as possible.
Enumeration
Enumerated Values:
1unknown
2up
3down
4warning
.1.3.6.1.4.1.9.9.117.1.4.1.1.1
The air flow direction of the fan or fan tray.
unknown(1) - unknown.
frontToBack(2) - air flow from front to back
backToFront(3) - air flow from back to front
Enumeration
Enumerated Values:
1unknown
2frontToBack
3backToFront
.1.3.6.1.4.1.9.9.117.1.4.1.1.2

cefcFanTable

table
.1.3.6.1.4.1.9.9.117.1.4.2 · 1 row entry · 2 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cefcFanTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-ENTITY-FRU-CONTROL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-ENTITY-FRU-CONTROL-MIB::cefcFanTable'
This table contains a list of fan information
for all the fans that have entPhysicalTable
entries with 'fan' in the entPhysicalClass
and capable of providing management information
defined in this table.
cefcFanEntry row .1.3.6.1.4.1.9.9.117.1.4.2.1
An entry containing management information
applicable to a particular fan unit.

Entries are created by the agent at system power-up or
fan or fan tray insertion. Entries are deleted
by the agent at the f…
Column Syntax OID
The speed of the fan.
rpmSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.117.1.4.2.1.1
The percent of speed relative to the maximum
speed of the fan.
percentCefcPercentOrMinusOne
Type Constraints:
range: -1..100
.1.3.6.1.4.1.9.9.117.1.4.2.1.2
.1.3.6.1.4.1.9.9.117.1.5.1 · 1 row entry · 1 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cefcPhysicalTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-ENTITY-FRU-CONTROL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-ENTITY-FRU-CONTROL-MIB::cefcPhysicalTable'
This table contains one row per physical entity.
cefcPhysicalEntry row .1.3.6.1.4.1.9.9.117.1.5.1.1
Information about a particular physical entity.
Column Syntax OID
The status of this physical entity.
other(1) - the status is not any of the listed below.
supported(2) - this entity is supported.
unsupported(3) - this entity is unsupported.
incompatible(4) - this entity is incompatib…
Enumeration
Enumerated Values:
1other
2supported
3unsupported
4incompatible
.1.3.6.1.4.1.9.9.117.1.5.1.1.1
.1.3.6.1.4.1.9.9.117.1.6.1 · 1 row entry · 2 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cefcPowerSupplyInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-ENTITY-FRU-CONTROL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-ENTITY-FRU-CONTROL-MIB::cefcPowerSupplyInputTable'
This table contains the power input information
for all the power supplies that have entPhysicalTable
entries with 'powerSupply' in the entPhysicalClass. 
          
The entries are created by the agent at the system
power-up or power supply insertion.
          
Entries are deleted by the agent upon power supply
removal.
          
The number of entries is determined by the number of
power supplies and number of power inputs on the power 
supply.
cefcPowerSupplyInputEntry row .1.3.6.1.4.1.9.9.117.1.6.1.1
An entry containing power input management information
applicable to a particular power supply and input.
Column Syntax OID
A unique value, greater than zero, for each input on
a power supply.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.117.1.6.1.1.1
The type of an input power detected on the power
supply.

unknown(1): No input power is detected.

acLow(2): Lower rating AC input power is detected.

acHigh(3): Higher rating A…
Enumeration
Enumerated Values:
1unknown
2acLow
3acHigh
4dcLow
5dcHigh
.1.3.6.1.4.1.9.9.117.1.6.1.1.2
.1.3.6.1.4.1.9.9.117.1.6.2 · 1 row entry · 3 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cefcPowerSupplyOutputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-ENTITY-FRU-CONTROL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-ENTITY-FRU-CONTROL-MIB::cefcPowerSupplyOutputTable'
This table contains a list of possible output
mode for the power supplies, whose ENTITY-MIB
entPhysicalTable entries have an entPhysicalClass
of 'powerSupply'. It also indicate which mode
is the operational mode within the system.
cefcPowerSupplyOutputEntry row .1.3.6.1.4.1.9.9.117.1.6.2.1
A cefcPowerSupplyOutputTable entry lists the
power output capacity and its operational status
for manageable components of type PhysicalClass
'powerSupply'.

Entries are created by the agent at the system
po…
Column Syntax OID
A unique value, greater than zero, for each
possible output mode on a power supply.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.117.1.6.2.1.1
The output capacity of the power supply.
FRUCurrentType
Type Constraints:
range: -1000000000..1000000000
.1.3.6.1.4.1.9.9.117.1.6.2.1.2
A value of 'true' indicates that this mode is the
operational mode of the power supply output
capacity.

A value of 'false' indicates that this mode is not
the operational mode of the power supply output
c…
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.9.9.117.1.6.2.1.3
.1.3.6.1.4.1.9.9.117.1.7.1 · 1 row entry · 2 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cefcChassisCoolingTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-ENTITY-FRU-CONTROL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-ENTITY-FRU-CONTROL-MIB::cefcChassisCoolingTable'
This table contains the cooling capacity
information of the chassis whose ENTITY-MIB
entPhysicalTable entries have an
entPhysicalClass of 'chassis'.
cefcChassisCoolingEntry row .1.3.6.1.4.1.9.9.117.1.7.1.1
A cefcChassisCoolingEntry lists the maximum
cooling capacity that could be provided
for one slot on the manageable components of type
PhysicalClass 'chassis'.

Entries are created by the agent if the corres…
Column Syntax OID
The maximum cooling capacity that could be provided
for any slot in this chassis.

The default unit of the cooling capacity is 'cfm', if
cefcChassisPerSlotCoolingUnit is not supported.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.117.1.7.1.1.1
The unit of the maximum cooling capacity for any slot
in this chassis.
FRUCoolingUnit
Type Values:
1cfm
2watts
.1.3.6.1.4.1.9.9.117.1.7.1.1.2
.1.3.6.1.4.1.9.9.117.1.7.2 · 1 row entry · 2 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cefcFanCoolingTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-ENTITY-FRU-CONTROL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-ENTITY-FRU-CONTROL-MIB::cefcFanCoolingTable'
This table contains the cooling capacity
information of the fans whose ENTITY-MIB
entPhysicalTable entries have an
entPhysicalClass of 'fan'.
cefcFanCoolingEntry row .1.3.6.1.4.1.9.9.117.1.7.2.1
A cefcFanCoolingEntry lists the cooling
capacity that is provided by the
manageable components of type PhysicalClass
'fan'.

Entries are created by the agent if the corresponding
entry is created in ENTITY…
Column Syntax OID
The cooling capacity that is provided by this fan.

The default unit of the fan cooling capacity is 'cfm',
if cefcFanCoolingCapacityUnit is not supported.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.117.1.7.2.1.1
The unit of the fan cooling capacity.
FRUCoolingUnit
Type Values:
1cfm
2watts
.1.3.6.1.4.1.9.9.117.1.7.2.1.2
.1.3.6.1.4.1.9.9.117.1.7.3 · 1 row entry · 2 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cefcModuleCoolingTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-ENTITY-FRU-CONTROL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-ENTITY-FRU-CONTROL-MIB::cefcModuleCoolingTable'
This table contains the cooling requirement for
all the manageable components of type entPhysicalClass
'module'.
cefcModuleCoolingEntry row .1.3.6.1.4.1.9.9.117.1.7.3.1
A cefcModuleCoolingEntry lists the cooling
requirement for a manageable components of type
entPhysicalClass 'module'.

Entries are created by the agent at the system
power-up or module insertion.
Column Syntax OID
The cooling requirement of the module and its daughter
cards.

The default unit of the module cooling requirement is
'cfm', if cefcModuleCoolingUnit is not supported.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.117.1.7.3.1.1
The unit of the cooling requirement of the module and its
daughter cards.
FRUCoolingUnit
Type Values:
1cfm
2watts
.1.3.6.1.4.1.9.9.117.1.7.3.1.2
.1.3.6.1.4.1.9.9.117.1.7.4 · 1 row entry · 5 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cefcFanCoolingCapTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-ENTITY-FRU-CONTROL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-ENTITY-FRU-CONTROL-MIB::cefcFanCoolingCapTable'
This table contains a list of the possible cooling
capacity modes and properties of the fans, whose 
ENTITY-MIB entPhysicalTable entries have an 
entPhysicalClass of 'fan'.
cefcFanCoolingCapEntry row .1.3.6.1.4.1.9.9.117.1.7.4.1
A cefcFanCoolingCapacityEntry lists the cooling
capacity mode of a manageable components of type
entPhysicalClass 'fan'. It also lists the corresponding
cooling capacity provided and the power consumed
by the fan on thi…
Column Syntax OID
An arbitrary value that uniquely identifies a
cooling capacity mode for a fan.
Unsigned32
Constraints:
range: 1-4095
.1.3.6.1.4.1.9.9.117.1.7.4.1.1
A textual description of the cooling capacity
mode of the fan.
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.117.1.7.4.1.2
The cooling capacity that could be provided
when the fan is operating in this mode.

The default unit of the cooling capacity is 'cfm',
if cefcFanCoolingCapCapacityUnit is not supported.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.117.1.7.4.1.3
The power consumption of the fan when operating in
in this mode.
FRUCurrentType
Type Constraints:
range: -1000000000..1000000000
.1.3.6.1.4.1.9.9.117.1.7.4.1.4
The unit of the fan cooling capacity when operating
in this mode.
FRUCoolingUnit
Type Values:
1cfm
2watts
.1.3.6.1.4.1.9.9.117.1.7.4.1.5
.1.3.6.1.4.1.9.9.117.1.8.1 · 1 row entry · 1 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cefcConnectorRatingTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-ENTITY-FRU-CONTROL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-ENTITY-FRU-CONTROL-MIB::cefcConnectorRatingTable'
This table contains the connector power
ratings of FRUs. 
          
Only components with power connector rating 
management are listed in this table.
cefcConnectorRatingEntry row .1.3.6.1.4.1.9.9.117.1.8.1.1
A cefcConnectorRatingEntry lists the
power connector rating information of a
component in the system.

An entry or entries are created by the agent
when an physical entity with connector rating
management …
Column Syntax OID
The maximum power that the component's
connector can withdraw.
FRUCurrentType
Type Constraints:
range: -1000000000..1000000000
.1.3.6.1.4.1.9.9.117.1.8.1.1.1
.1.3.6.1.4.1.9.9.117.1.8.2 · 1 row entry · 1 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cefcModulePowerConsumptionTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-ENTITY-FRU-CONTROL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-ENTITY-FRU-CONTROL-MIB::cefcModulePowerConsumptionTable'
This table contains the total power consumption
information for modules whose ENTITY-MIB 
entPhysicalTable entries have an entPhysicalClass 
of 'module'.
cefcModulePowerConsumptionEntry row .1.3.6.1.4.1.9.9.117.1.8.2.1
A cefcModulePowerConsumptionEntry lists the total
power consumption of a manageable components of type
entPhysicalClass 'module'.

Entries are created by the agent at the system
power-up or module insertion.…
Column Syntax OID
The combined power consumption to operate the module
and its submodule(s) and inline-power device(s).
FRUCurrentType
Type Constraints:
range: -1000000000..1000000000
.1.3.6.1.4.1.9.9.117.1.8.2.1.1