CISCO-ENTITY-FRU-CONTROL-MIB

Monitored by Observium
        The CISCO-ENTITY-FRU-CONTROL-MIB is used to monitor
and configure operational status of 
Field Replaceable Units (FRUs) and other managable 
physical entities of the system listed in the 
Entity-MIB (RFC 2737) entPhysicalTable. 
        
FRUs include assemblies such as power supplies, fans, 
processor modules, interface modules, etc.
    
Observium actively monitors this MIB
Observium uses this MIB in discovery or polling workflows on applicable devices.
Sensors
Explore Observium network monitoring
Source file
CISCO-ENTITY-FRU-CONTROL-MIB
Last revised
Identity
ciscoEntityFRUControlMIB
Base OID
1.3.6.1.4.1.9.9.117
Imported Objects
CISCO-SMI ciscoMgmt
ENTITY-MIB entPhysicalClass entPhysicalContainedIn entPhysicalIndex entPhysicalModelName entPhysicalName entPhysicalVendorType
INET-ADDRESS-MIB InetAddress InetAddressType
SNMP-FRAMEWORK-MIB SnmpAdminString
SNMPv2-CONF MODULE-COMPLIANCE (no object page) NOTIFICATION-GROUP (no object page) OBJECT-GROUP (no object page)
SNMPv2-SMI Integer32 MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-TYPE (no object page) Unsigned32
SNMPv2-TC DisplayString TEXTUAL-CONVENTION (no object page) TimeStamp TruthValue
Net-SNMP examples using the cisco MIB directory Show commands

These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.

Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'CISCO-ENTITY-FRU-CONTROL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CISCO-ENTITY-FRU-CONTROL-MIB::ciscoEntityFRUControlMIB'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-ENTITY-FRU-CONTROL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-ENTITY-FRU-CONTROL-MIB::ciscoEntityFRUControlMIB'
How SNMP, Net-SNMP, MIB paths, and variants work
Objects (107)
16 directly used by Observium
.1.3.6.1.4.1.9.9.117
.1.3.6.1.4.1.9.9.117.1
.1.3.6.1.4.1.9.9.117.1.1
.1.3.6.1.4.1.9.9.117.1.1.1
.1.3.6.1.4.1.9.9.117.1.1.1.1
.1.3.6.1.4.1.9.9.117.1.1.1.1.1
cefcPowerUnits OBS ✓
.1.3.6.1.4.1.9.9.117.1.1.1.1.2
.1.3.6.1.4.1.9.9.117.1.1.1.1.3
.1.3.6.1.4.1.9.9.117.1.1.1.1.4
.1.3.6.1.4.1.9.9.117.1.1.1.1.5
Enumeration
.1.3.6.1.4.1.9.9.117.1.1.1.1.6
.1.3.6.1.4.1.9.9.117.1.1.1.1.7
.1.3.6.1.4.1.9.9.117.1.1.2
.1.3.6.1.4.1.9.9.117.1.1.2.1
.1.3.6.1.4.1.9.9.117.1.1.2.1.1
.1.3.6.1.4.1.9.9.117.1.1.2.1.2
.1.3.6.1.4.1.9.9.117.1.1.2.1.3
Bits
.1.3.6.1.4.1.9.9.117.1.1.2.1.4
.1.3.6.1.4.1.9.9.117.1.1.2.1.5
cefcMaxDefaultInLinePower deprecated r/w
miliwattsInteger32
.1.3.6.1.4.1.9.9.117.1.1.3
.1.3.6.1.4.1.9.9.117.1.1.4
.1.3.6.1.4.1.9.9.117.1.1.4.1
.1.3.6.1.4.1.9.9.117.1.1.4.1.1
.1.3.6.1.4.1.9.9.117.1.1.4.1.2
.1.3.6.1.4.1.9.9.117.1.1.4.1.3
.1.3.6.1.4.1.9.9.117.1.1.4.1.4
.1.3.6.1.4.1.9.9.117.1.1.4.1.5
.1.3.6.1.4.1.9.9.117.1.1.4.1.6
.1.3.6.1.4.1.9.9.117.1.1.5
.1.3.6.1.4.1.9.9.117.1.2
.1.3.6.1.4.1.9.9.117.1.2.1
cefcModuleEntry OBS ✓
.1.3.6.1.4.1.9.9.117.1.2.1.1
cefcModuleAdminStatus OBS ✓ r/w
.1.3.6.1.4.1.9.9.117.1.2.1.1.1
.1.3.6.1.4.1.9.9.117.1.2.1.1.10
.1.3.6.1.4.1.9.9.117.1.2.1.1.2
.1.3.6.1.4.1.9.9.117.1.2.1.1.3
.1.3.6.1.4.1.9.9.117.1.2.1.1.4
.1.3.6.1.4.1.9.9.117.1.2.1.1.5
.1.3.6.1.4.1.9.9.117.1.2.1.1.6
.1.3.6.1.4.1.9.9.117.1.2.1.1.7
.1.3.6.1.4.1.9.9.117.1.2.1.1.8
.1.3.6.1.4.1.9.9.117.1.2.1.1.9
.1.3.6.1.4.1.9.9.117.1.2.2
.1.3.6.1.4.1.9.9.117.1.2.2.1
.1.3.6.1.4.1.9.9.117.1.2.2.1.1
.1.3.6.1.4.1.9.9.117.1.2.2.1.2
.1.3.6.1.4.1.9.9.117.1.2.3
.1.3.6.1.4.1.9.9.117.1.2.3.1
Enumeration
.1.3.6.1.4.1.9.9.117.1.2.3.1.1
.1.3.6.1.4.1.9.9.117.1.3
.1.3.6.1.4.1.9.9.117.1.3.1
.1.3.6.1.4.1.9.9.117.1.3.2
.1.3.6.1.4.1.9.9.117.1.4
.1.3.6.1.4.1.9.9.117.1.4.1
.1.3.6.1.4.1.9.9.117.1.4.1.1
Enumeration
.1.3.6.1.4.1.9.9.117.1.4.1.1.1
Enumeration
.1.3.6.1.4.1.9.9.117.1.4.1.1.2
.1.3.6.1.4.1.9.9.117.1.4.2
cefcFanEntry OBS ✓
.1.3.6.1.4.1.9.9.117.1.4.2.1
cefcFanSpeed OBS ✓
.1.3.6.1.4.1.9.9.117.1.4.2.1.1
.1.3.6.1.4.1.9.9.117.1.4.2.1.2
.1.3.6.1.4.1.9.9.117.1.5
.1.3.6.1.4.1.9.9.117.1.5.1
.1.3.6.1.4.1.9.9.117.1.5.1.1
Enumeration
.1.3.6.1.4.1.9.9.117.1.5.1.1.1
.1.3.6.1.4.1.9.9.117.1.6
.1.3.6.1.4.1.9.9.117.1.6.1
.1.3.6.1.4.1.9.9.117.1.6.1.1
.1.3.6.1.4.1.9.9.117.1.6.1.1.1
Enumeration
.1.3.6.1.4.1.9.9.117.1.6.1.1.2
.1.3.6.1.4.1.9.9.117.1.6.2
.1.3.6.1.4.1.9.9.117.1.6.2.1
.1.3.6.1.4.1.9.9.117.1.6.2.1.1
.1.3.6.1.4.1.9.9.117.1.6.2.1.2
.1.3.6.1.4.1.9.9.117.1.6.2.1.3
.1.3.6.1.4.1.9.9.117.1.7
.1.3.6.1.4.1.9.9.117.1.7.1
.1.3.6.1.4.1.9.9.117.1.7.1.1
.1.3.6.1.4.1.9.9.117.1.7.1.1.1
.1.3.6.1.4.1.9.9.117.1.7.1.1.2
.1.3.6.1.4.1.9.9.117.1.7.2
.1.3.6.1.4.1.9.9.117.1.7.2.1
.1.3.6.1.4.1.9.9.117.1.7.2.1.1
.1.3.6.1.4.1.9.9.117.1.7.2.1.2
.1.3.6.1.4.1.9.9.117.1.7.3
.1.3.6.1.4.1.9.9.117.1.7.3.1
.1.3.6.1.4.1.9.9.117.1.7.3.1.1
.1.3.6.1.4.1.9.9.117.1.7.3.1.2
.1.3.6.1.4.1.9.9.117.1.7.4
.1.3.6.1.4.1.9.9.117.1.7.4.1
Unsigned32
.1.3.6.1.4.1.9.9.117.1.7.4.1.1
.1.3.6.1.4.1.9.9.117.1.7.4.1.2
.1.3.6.1.4.1.9.9.117.1.7.4.1.3
.1.3.6.1.4.1.9.9.117.1.7.4.1.4
.1.3.6.1.4.1.9.9.117.1.7.4.1.5
.1.3.6.1.4.1.9.9.117.1.8
.1.3.6.1.4.1.9.9.117.1.8.1
.1.3.6.1.4.1.9.9.117.1.8.1.1
.1.3.6.1.4.1.9.9.117.1.8.1.1.1
.1.3.6.1.4.1.9.9.117.1.8.2
.1.3.6.1.4.1.9.9.117.1.8.2.1
.1.3.6.1.4.1.9.9.117.1.8.2.1.1
.1.3.6.1.4.1.9.9.117.2
.1.3.6.1.4.1.9.9.117.2.0
.1.3.6.1.4.1.9.9.117.3
.1.3.6.1.4.1.9.9.117.3.1
.1.3.6.1.4.1.9.9.117.3.2
Dependencies (9) 7 direct · 2 transitive Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Type Definitions (11)
Integer32 range: -1..100
Enumeration
down(1)
up(2)
unknown(3)
goingDown(4)
Enumeration
cfm(1)
watts(2)
Integer32 range: -1000000000..1000000000
Unsigned32
Enumeration
enabled(1)
disabled(2)
reset(3)
outOfServiceAdmin(4)
Enumeration
unknown(1)
ok(2)
disabled(3)
okButDiagFailed(4)
boot(5)
selfTest(6)
failed(7)
missing(8)
mismatchWithParent(9)
mismatchConfig(10)
diagFailed(11)
dormant(12)
outOfServiceAdmin(13)
outOfServiceEnvTemp(14)
poweredDown(15)
poweredUp(16)
powerDenied(17)
powerCycled(18)
okButPowerOverWarning(19)
okButPowerOverCritical(20)
syncInProgress(21)
upgrading(22)
okButAuthFailed(23)
mdr(24)
fwMismatchFound(25)
fwDownloadSuccess(26)
fwDownloadFailure(27)
Enumeration
unknown(1)
powerUp(2)
parityError(3)
clearConfigReset(4)
manualReset(5)
watchDogTimeoutReset(6)
resourceOverflowReset(7)
missingTaskReset(8)
lowVoltageReset(9)
controllerReset(10)
systemReset(11)
switchoverReset(12)
upgradeReset(13)
downgradeReset(14)
cacheErrorReset(15)
deviceDriverReset(16)
softwareExceptionReset(17)
restoreConfigReset(18)
abortRevReset(19)
burnBootReset(20)
standbyCdHealthierReset(21)
nonNativeConfigClearReset(22)
memoryProtectionErrorReset(23)
Enumeration
on(1)
off(2)
inlineAuto(3)
inlineOn(4)
powerCycle(5)
Enumeration
offEnvOther(1)
on(2)
offAdmin(3)
offDenied(4)
offEnvPower(5)
offEnvTemp(6)
offEnvFan(7)
failed(8)
onButFanFail(9)
offCooling(10)
offConnectorRating(11)
onButInlinePowerFail(12)
Enumeration
notsupported(1)
redundant(2)
combined(3)
nonRedundant(4)
psRedundant(5)
inPwrSrcRedundant(6)
psRedundantSingleInput(7)
Conformance Groups (35)
The collection of objects which are used
to configure and monitor power-control for
FRUs.
.1.3.6.1.4.1.9.9.117.3.2.1
The collection of objects which are used
to configure and monitor power-control for
FRUs.
.1.3.6.1.4.1.9.9.117.3.2.2
The collection of objects which are used to get the
operational state and redundancy state of the modules
.1.3.6.1.4.1.9.9.117.3.2.3
The collection of objects which are used to
configure and monitor inline power control for
FRUs.
.1.3.6.1.4.1.9.9.117.3.2.4
The collection of objects which are used to
enable notification.
.1.3.6.1.4.1.9.9.117.3.2.5
The notifications which a FRU Management entity is
required to implement.
.1.3.6.1.4.1.9.9.117.3.2.6
The collection of objects which are used to get the
operational state and redundancy state of the modules
.1.3.6.1.4.1.9.9.117.3.2.7
The collection of objects which are used to retrieve
the total and used capacity of a power supply for both
system and inline power.
.1.3.6.1.4.1.9.9.117.3.2.8
The collection of objects which show information of the
status of Fan Tray FRUs.
.1.3.6.1.4.1.9.9.117.3.2.9
The collection of objects which show information of the
Physical Entity.
.1.3.6.1.4.1.9.9.117.3.2.10
The additional notifications for FRU status.
.1.3.6.1.4.1.9.9.117.3.2.11
The collection of objects which are used
to monitor the device's power supply operational
redundancy mode.
.1.3.6.1.4.1.9.9.117.3.2.12
The collection of objects which are used to
configure and monitor inline power control for
FRUs.
.1.3.6.1.4.1.9.9.117.3.2.13
The collection of objects which are used to get the
state change reason and up time of the modules.
.1.3.6.1.4.1.9.9.117.3.2.14
The collection of objects which are used to get the
information specific to intelligent modules.
.1.3.6.1.4.1.9.9.117.3.2.15
The collection of objects which are used to get the
power capacity information
.1.3.6.1.4.1.9.9.117.3.2.16
The collection of objects which are used to get the
cooling capacity information.
.1.3.6.1.4.1.9.9.117.3.2.17
The collection of objects which are used to get the
power connector rating and module power total
consumption information.
.1.3.6.1.4.1.9.9.117.3.2.18
The collection of objects which are used to
enable additional group of notifications.
.1.3.6.1.4.1.9.9.117.3.2.19
The additional notification for notify the
power capacity mode change.
.1.3.6.1.4.1.9.9.117.3.2.20
The collection of objects which are used to
monitor inline power usage for FRUs.
.1.3.6.1.4.1.9.9.117.3.2.21
The collection of objects provide additional
information about the device's power supply
redundancy.
.1.3.6.1.4.1.9.9.117.3.2.22
The collection of objects provide the cooling
capacity modes and properties of the fans.
.1.3.6.1.4.1.9.9.117.3.2.23
The collection of objects which show information of the
local switching status of modules.
.1.3.6.1.4.1.9.9.117.3.2.24
The collection of objects provide the power-related
realtime information of the manageable entities.
.1.3.6.1.4.1.9.9.117.3.2.25
The collection of objects provide the power-related
capability information of the manageable entities.
.1.3.6.1.4.1.9.9.117.3.2.26
The collection of objects provide the cooling unit
information of the manageable entities.
.1.3.6.1.4.1.9.9.117.3.2.27
The collection of objects provide the cooling unit
information of the manageable fan entities.
.1.3.6.1.4.1.9.9.117.3.2.28
The collection of objects which are used to get the
cooling capacity or requirement information.
.1.3.6.1.4.1.9.9.117.3.2.29
The collection of objects provide the cooling
capacity modes and properties of the fans.
.1.3.6.1.4.1.9.9.117.3.2.30
The collection of objects provide the direction
information of the manageable fan entities.
.1.3.6.1.4.1.9.9.117.3.2.31
The collection of objects provide the speed
information of the manageable fan entities.
.1.3.6.1.4.1.9.9.117.3.2.32
The collection of objects which are used to retrieve
the actual input and output current of a power supply.
.1.3.6.1.4.1.9.9.117.3.2.33
The collection of objects which povide the VM
module opertional status information.
.1.3.6.1.4.1.9.9.117.3.2.34
A collection of notifications for VM module
status change.
.1.3.6.1.4.1.9.9.117.3.2.35
Compliance Statements (10)

OID .1.3.6.1.4.1.9.9.117.3.1.1
An Entity-MIB implementation can implement this group to
provide FRU power status and control.
Required groups
mandatory cefcMIBPowerModeGroup
optional cefcMIBPowerFRUControlGroup The cefcMIBPowerFRUControlGroup must be implemented
for FRUs that have power control

OID .1.3.6.1.4.1.9.9.117.3.1.2
An Entity-MIB implementation can implement this group to
provide FRU power status and control.
Required groups
mandatory cefcMIBPowerModeGroup
mandatory cefcMgmtNotificationsGroup
optional cefcMIBPowerFRUControlGroup The cefcMIBPowerFRUControlGroup must be implemented
for FRUs that have power control
optional cefcMIBModuleGroup The cefcMIBModuleGroup must be implemented for
FRUs that are of module type.
optional cefcMIBInLinePowerControlGroup The cefcMIBInLinePowerControlGroup must be implemented
for FRUs that have inline power control
optional cefcMIBNotificationEnablesGroup The cefcMIBNotificationEnablesGroup must be
implemented for FRUs that have notification

OID .1.3.6.1.4.1.9.9.117.3.1.3
An Entity-MIB implementation can implement this group to
provide FRU power status and control.
Required groups
mandatory cefcMIBPowerModeGroup
mandatory cefcMgmtNotificationsGroup
optional cefcMIBPowerFRUControlGroup The cefcMIBPowerFRUControlGroup must be implemented
for FRUs that have power control
optional cefcMIBModuleGroup The cefcMIBModuleGroup must be implemented for
FRUs that are of module type.
optional cefcMIBInLinePowerControlGroup The cefcMIBInLinePowerControlGroup must be
implemented for FRUs that have inline power control
optional cefcMIBNotificationEnablesGroup The cefcMIBNotificationEnablesGroup must be
implemented for FRUs that have notification
optional cefcModuleGroupRev1 The cefcModuleGroupRev1 is not mandatory for
agents with FRUs that are of module type.

OID .1.3.6.1.4.1.9.9.117.3.1.4
An Entity-MIB implementation can implement this group to
provide FRU power status and control.
Required groups
mandatory cefcMIBPowerModeGroup
mandatory cefcMgmtNotificationsGroup
optional cefcMIBPowerFRUControlGroup The cefcMIBPowerFRUControlGroup must be implemented
for FRUs that have power control
optional cefcMIBModuleGroup The cefcMIBModuleGroup must be implemented for
FRUs that are of module type.
optional cefcMIBInLinePowerControlGroup The cefcMIBInLinePowerControlGroup must be
implemented for FRUs that have inline power control
optional cefcMIBNotificationEnablesGroup The cefcMIBNotificationEnablesGroup must be
implemented for FRUs that have notification
optional cefcModuleGroupRev1 The cefcModuleGroupRev1 is not mandatory for
agents with FRUs that are of module type.
optional cefcMIBPowerFRUValueGroup The cefcMIBPowerFRUValueGroup must be implemented for
power supply FRUs that have variable output
Object refinements
ObjectAccessSyntaxDescription
cefcFRUTotalSystemCurrent readonly
Write access is not required.
cefcFRUDrawnSystemCurrent readonly
Write access is not required.
cefcFRUTotalInlineCurrent readonly
Write access is not required.
cefcFRUDrawnInlineCurrent readonly
Write access is not required.

OID .1.3.6.1.4.1.9.9.117.3.1.5
An Entity-MIB implementation can implement this group to
provide FRU power status and control.
Required groups
mandatory cefcMIBPowerModeGroup
mandatory cefcMgmtNotificationsGroup
mandatory cefcMgmtNotificationsGroup2
optional cefcMIBPowerFRUControlGroup The cefcMIBPowerFRUControlGroup must be implemented
for FRUs that have power control
optional cefcMIBModuleGroup The cefcMIBModuleGroup must be implemented for
FRUs that are of module type.
optional cefcMIBInLinePowerControlGroup The cefcMIBInLinePowerControlGroup must be
implemented for FRUs that have inline power control
optional cefcMIBNotificationEnablesGroup The cefcMIBNotificationEnablesGroup must be
implemented for FRUs that have notification
optional cefcModuleGroupRev1 The cefcModuleGroupRev1 is not mandatory for
agents with FRUs that are of module type.
optional cefcMIBPowerFRUValueGroup The cefcMIBPowerFRUValueGroup must be implemented for
power supply FRUs that have variable output
optional cefcMIBFanTrayStatusGroup The cefcMIBFanTrayStatusGroup must be implemented
in all systems which can detect the status of Fan
Tray FRUs.
optional cefcMIBPhysicalGroup The collection of objects which show information of
the Physical Entity.
Object refinements
ObjectAccessSyntaxDescription
cefcFRUTotalSystemCurrent readonly
Write access is not required.
cefcFRUDrawnSystemCurrent readonly
Write access is not required.
cefcFRUTotalInlineCurrent readonly
Write access is not required.
cefcFRUDrawnInlineCurrent readonly
Write access is not required.

OID .1.3.6.1.4.1.9.9.117.3.1.6
An Entity-MIB implementation can implement this group to
provide FRU power status and control.
Required groups
mandatory cefcMIBPowerModeGroup
mandatory cefcMgmtNotificationsGroup
optional cefcMIBPowerFRUControlGroup The cefcMIBPowerFRUControlGroup must be implemented
for FRUs that have power control
optional cefcMIBModuleGroup The cefcMIBModuleGroup must be implemented for
FRUs that are of module type.
optional cefcMIBInLinePowerControlGroupRev1 The cefcMIBInLinePowerControlGroup must be
implemented for FRUs that have inline power control
optional cefcMIBNotificationEnablesGroup The cefcMIBNotificationEnablesGroup must be
implemented for FRUs that have notification
optional cefcModuleGroupRev1 The cefcModuleGroupRev1 is not mandatory for
agents with FRUs that are of module type.
optional cefcMIBPowerFRUValueGroup The cefcMIBPowerFRUValueGroup must be implemented for
power supply FRUs that have variable output
optional cefcMIBFanTrayStatusGroup The cefcMIBFanTrayStatusGroup must be implemented
in all systems which can detect the status of Fan
Tray FRUs.
optional cefcMIBPhysicalGroup The collection of objects which show information of
the Physical Entity.
optional cefcMgmtNotificationsGroup2 The implementation of this group of notifications
is optional.
optional cefcMIBPowerOperModeGroup The cefcMIBPowerOperModeGroup must be
implemented for the device which supports
power supply operational modes.
optional cefcModuleExtGroup Implementation of cefcModuleExtGroup is
optional.
optional cefcIntelliModuleGroup Implementation of cefcModuleAddrGroup is
optional.
Object refinements
ObjectAccessSyntaxDescription
cefcFRUTotalSystemCurrent readonly
Write access is not required.
cefcFRUDrawnSystemCurrent readonly
Write access is not required.
cefcFRUTotalInlineCurrent readonly
Write access is not required.
cefcFRUDrawnInlineCurrent readonly
Write access is not required.
cefcIntelliModuleIPAddrType
ipv4(1)
An implementation is only required to
support IPv4 addresses.

OID .1.3.6.1.4.1.9.9.117.3.1.7
An Entity-MIB implementation can implement this group to
provide FRU power status and control.
Required groups
mandatory cefcMIBPowerModeGroup
mandatory cefcMgmtNotificationsGroup
optional cefcMIBPowerFRUControlGroup The cefcMIBPowerFRUControlGroup must be implemented
for FRUs that have power control
optional cefcMIBModuleGroup The cefcMIBModuleGroup must be implemented for
FRUs that are of module type.
optional cefcMIBInLinePowerControlGroupRev1 The cefcMIBInLinePowerControlGroup must be
implemented for FRUs that have inline power control
optional cefcMIBNotificationEnablesGroup The cefcMIBNotificationEnablesGroup must be
implemented for FRUs that have notification
optional cefcModuleGroupRev1 The cefcModuleGroupRev1 is not mandatory for
agents with FRUs that are of module type.
optional cefcMIBPowerFRUValueGroup The cefcMIBPowerFRUValueGroup must be implemented for
power supply FRUs that have variable output
optional cefcMIBFanTrayStatusGroup The cefcMIBFanTrayStatusGroup must be implemented
in all systems which can detect the status of Fan
Tray FRUs.
optional cefcMIBPhysicalGroup The collection of objects which show information of
the Physical Entity.
optional cefcMgmtNotificationsGroup2 The implementation of this group of notifications
is optional.
optional cefcMIBPowerOperModeGroup The cefcMIBPowerOperModeGroup must be
implemented for the device which supports
power supply operational modes.
optional cefcModuleExtGroup Implementation of cefcModuleExtGroup is
optional.
optional cefcIntelliModuleGroup Implementation of cefcModuleAddrGroup is
optional.
optional cefcPowerCapacityGroup This group is mandatory for devices which
have the capability to populate power capacity
information.
optional cefcCoolingGroup This group is mandatory for devices which
have the capability to populate cooling
capacity information.
optional cefcConnectorRatingGroup This group is mandatory for devices which
have the capability to populate power
connector rating and module power total
consumption information.
optional cefcMIBNotificationEnablesGroup2 This group is mandatory for devices which
support the SNMP notification to notify
the power supply output capacity changes.
optional cefcMgmtNotificationsGroup3 This group is mandatory for devices which
support the SNMP notification to notify
the power supply output capacity changes.
Object refinements
ObjectAccessSyntaxDescription
cefcFRUTotalSystemCurrent readonly
Write access is not required.
cefcFRUDrawnSystemCurrent readonly
Write access is not required.
cefcFRUTotalInlineCurrent readonly
Write access is not required.
cefcFRUDrawnInlineCurrent readonly
Write access is not required.
cefcIntelliModuleIPAddrType
ipv4(1)
An implementation is only required to
support IPv4 addresses.

OID .1.3.6.1.4.1.9.9.117.3.1.8
An Entity-MIB implementation can implement this group to
provide FRU power status and control.
Required groups
mandatory cefcMIBPowerModeGroup
mandatory cefcMgmtNotificationsGroup
optional cefcMIBPowerFRUControlGroup The cefcMIBPowerFRUControlGroup must be implemented
for FRUs that have power control
optional cefcMIBModuleGroup The cefcMIBModuleGroup must be implemented for
FRUs that are of module type.
optional cefcMIBInLinePowerControlGroupRev1 The cefcMIBInLinePowerControlGroup must be
implemented for FRUs that have inline power control
optional cefcMIBNotificationEnablesGroup The cefcMIBNotificationEnablesGroup must be
implemented for FRUs that have notification
optional cefcModuleGroupRev1 The cefcModuleGroupRev1 is not mandatory for
agents with FRUs that are of module type.
optional cefcMIBPowerFRUValueGroup The cefcMIBPowerFRUValueGroup must be implemented for
power supply FRUs that have variable output
optional cefcMIBFanTrayStatusGroup The cefcMIBFanTrayStatusGroup must be implemented
in all systems which can detect the status of Fan
Tray FRUs.
optional cefcMIBPhysicalGroup The collection of objects which show information of
the Physical Entity.
optional cefcMgmtNotificationsGroup2 The implementation of this group of notifications
is optional.
optional cefcMIBPowerOperModeGroup The cefcMIBPowerOperModeGroup must be
implemented for the device which supports
power supply operational modes.
optional cefcModuleExtGroup Implementation of cefcModuleExtGroup is
optional.
optional cefcIntelliModuleGroup Implementation of cefcModuleAddrGroup is
optional.
optional cefcPowerCapacityGroup This group is mandatory for devices which
have the capability to populate power capacity
information.
optional cefcCoolingGroup This group is mandatory for devices which
have the capability to populate cooling
capacity information.
optional cefcConnectorRatingGroup This group is mandatory for devices which
have the capability to populate power
connector rating and module power total
consumption information.
optional cefcMIBNotificationEnablesGroup2 This group is mandatory for devices which
support the SNMP notification to notify
the power supply output capacity changes.
optional cefcMgmtNotificationsGroup3 This group is mandatory for devices which
support the SNMP notification to notify
the power supply output capacity changes.
optional cefcMIBInLinePowerCurrentGroup This group is mandatory for devices which
have the capability to populate inline power
usage information.
optional cefcMIBPowerRedundancyInfoGroup This group is mandatory for devices which
have the capability to populate the reason
why the redundancy of the power supplies cannot
be achieved.
optional cefcFanCoolingCapGroup This group is mandatory for devices which
can provide the cooling capacity modes
and properties of the fans in the system.
Object refinements
ObjectAccessSyntaxDescription
cefcFRUTotalSystemCurrent readonly
Write access is not required.
cefcFRUDrawnSystemCurrent readonly
Write access is not required.
cefcFRUTotalInlineCurrent readonly
Write access is not required.
cefcFRUDrawnInlineCurrent readonly
Write access is not required.
cefcIntelliModuleIPAddrType
ipv4(1)
An implementation is only required to
support IPv4 addresses.

OID .1.3.6.1.4.1.9.9.117.3.1.9
An Entity-MIB implementation can implement this group to
provide FRU power status and control.
Required groups
mandatory cefcMIBPowerModeGroup
mandatory cefcMgmtNotificationsGroup
optional cefcMIBPowerFRUControlGroup The cefcMIBPowerFRUControlGroup must be implemented
for FRUs that have power control
optional cefcMIBModuleGroup The cefcMIBModuleGroup must be implemented for
FRUs that are of module type.
optional cefcMIBInLinePowerControlGroupRev1 The cefcMIBInLinePowerControlGroup must be
implemented for FRUs that have inline power control
optional cefcMIBNotificationEnablesGroup The cefcMIBNotificationEnablesGroup must be
implemented for FRUs that have notification
optional cefcModuleGroupRev1 The cefcModuleGroupRev1 is not mandatory for
agents with FRUs that are of module type.
optional cefcMIBPowerFRUValueGroup The cefcMIBPowerFRUValueGroup must be implemented for
power supply FRUs that have variable output
optional cefcMIBFanTrayStatusGroup The cefcMIBFanTrayStatusGroup must be implemented
in all systems which can detect the status of Fan
Tray FRUs.
optional cefcMIBPhysicalGroup The collection of objects which show information of
the Physical Entity.
optional cefcMgmtNotificationsGroup2 The implementation of this group of notifications
is optional.
optional cefcMIBPowerOperModeGroup The cefcMIBPowerOperModeGroup must be
implemented for the device which supports
power supply operational modes.
optional cefcModuleExtGroup Implementation of cefcModuleExtGroup is
optional.
optional cefcIntelliModuleGroup Implementation of cefcModuleAddrGroup is
optional.
optional cefcPowerCapacityGroup This group is mandatory for devices which
have the capability to populate power capacity
information.
optional cefcConnectorRatingGroup This group is mandatory for devices which
have the capability to populate power
connector rating and module power total
consumption information.
optional cefcMIBNotificationEnablesGroup2 This group is mandatory for devices which
support the SNMP notification to notify
the power supply output capacity changes.
optional cefcMgmtNotificationsGroup3 This group is mandatory for devices which
support the SNMP notification to notify
the power supply output capacity changes.
optional cefcMIBInLinePowerCurrentGroup This group is mandatory for devices which
have the capability to populate inline power
usage information.
optional cefcMIBPowerRedundancyInfoGroup This group is mandatory for devices which
have the capability to populate the reason
why the redundancy of the power supplies cannot
be achived.
optional cefcFanCoolingCapGroup This group is mandatory for devices which
can provide the cooling capacity modes
and properties of the fans in the system.
optional cefcMIBModuleLocalSwitchingGroup This group is mandatory for devices which
support modules with local switching
functionality.
optional cefcFRUPowerRealTimeStatusGroup This group is mandatory for devices which
support power related realtime status.
optional cefcFRUPowerCapabilityGroup This group is mandatory for devices which
support power related capability information.
optional cefcFRUCoolingUnitGroup This group is mandatory for devices which
support the cooling unit information.
optional cefcFRUFanCoolingUnitGroup This group is mandatory for devices which
support the fan capacity cooling unit information.
optional cefcCoolingGroup2 This group is mandatory for devices which
support the chassis cooling capacity and module
cooling requirement.
optional cefcFanCoolingGroup This group is mandatory for devices which
support the fan cooling capacity information.
Object refinements
ObjectAccessSyntaxDescription
cefcFRUTotalSystemCurrent readonly
Write access is not required.
cefcFRUDrawnSystemCurrent readonly
Write access is not required.
cefcFRUTotalInlineCurrent readonly
Write access is not required.
cefcFRUDrawnInlineCurrent readonly
Write access is not required.
cefcModuleLocalSwitchingMode readonly
Write access is not required.
cefcIntelliModuleIPAddrType
ipv4(1)
An implementation is only required to
support IPv4 addresses.

OID .1.3.6.1.4.1.9.9.117.3.1.10
An Entity-MIB implementation can implement this group to
provide FRU power status and control.
Required groups
mandatory cefcMIBPowerModeGroup
mandatory cefcMgmtNotificationsGroup
optional cefcMIBPowerFRUControlGroup The cefcMIBPowerFRUControlGroup must be implemented
for FRUs that have power control
optional cefcMIBModuleGroup The cefcMIBModuleGroup must be implemented for
FRUs that are of module type.
optional cefcMIBInLinePowerControlGroupRev1 The cefcMIBInLinePowerControlGroup must be
implemented for FRUs that have inline power control
optional cefcMIBNotificationEnablesGroup The cefcMIBNotificationEnablesGroup must be
implemented for FRUs that have notification
optional cefcModuleGroupRev1 The cefcModuleGroupRev1 is not mandatory for
agents with FRUs that are of module type.
optional cefcMIBPowerFRUValueGroup The cefcMIBPowerFRUValueGroup must be implemented for
power supply FRUs that have variable output
optional cefcMIBFanTrayStatusGroup The cefcMIBFanTrayStatusGroup must be implemented
in all systems which can detect the status of Fan
Tray FRUs.
optional cefcMIBPhysicalGroup The collection of objects which show information of
the Physical Entity.
optional cefcMgmtNotificationsGroup2 The implementation of this group of notifications
is optional.
optional cefcMIBPowerOperModeGroup The cefcMIBPowerOperModeGroup must be
implemented for the device which supports
power supply operational modes.
optional cefcModuleExtGroup Implementation of cefcModuleExtGroup is
optional.
optional cefcIntelliModuleGroup Implementation of cefcModuleAddrGroup is
optional.
optional cefcPowerCapacityGroup This group is mandatory for devices which
have the capability to populate power capacity
information.
optional cefcConnectorRatingGroup This group is mandatory for devices which
have the capability to populate power
connector rating and module power total
consumption information.
optional cefcMIBNotificationEnablesGroup2 This group is mandatory for devices which
support the SNMP notification to notify
the power supply output capacity changes.
optional cefcMgmtNotificationsGroup3 This group is mandatory for devices which
support the SNMP notification to notify
the power supply output capacity changes.
optional cefcMIBInLinePowerCurrentGroup This group is mandatory for devices which
have the capability to populate inline power
usage information.
optional cefcMIBPowerRedundancyInfoGroup This group is mandatory for devices which
have the capability to populate the reason
why the redundancy of the power supplies cannot
be achived.
optional cefcFanCoolingCapGroup This group is mandatory for devices which
can provide the cooling capacity modes
and properties of the fans in the system.
optional cefcMIBModuleLocalSwitchingGroup This group is mandatory for devices which
support modules with local switching
functionality.
optional cefcFRUPowerRealTimeStatusGroup This group is mandatory for devices which
support power related realtime status.
optional cefcFRUPowerCapabilityGroup This group is mandatory for devices which
support power related capability information.
optional cefcFRUCoolingUnitGroup This group is mandatory for devices which
support the cooling unit information.
optional cefcFRUFanCoolingUnitGroup This group is mandatory for devices which
support the fan capacity cooling unit information.
optional cefcCoolingGroup2 This group is mandatory for devices which
support the chassis cooling capacity and module
cooling requirement.
optional cefcFanCoolingGroup This group is mandatory for devices which
support the fan cooling capacity information.
optional cefcFanDirectionGroup This group is mandatory for devices which
support fan direction.
optional cefcFanSpeedGroup This group is mandatory for devices which
support fan speed.
optional cefcPowerSupplyActualGroup This group is mandatory for devices which
support actual input and output current of
a power supply.
optional cefcVmModuleGroup This group is mandatory for devices which
support VM module status.
optional cefcVmModuleNotifsGroup This group is mandatory for devices which
support VM module status notifications.
Object refinements
ObjectAccessSyntaxDescription
cefcFRUTotalSystemCurrent readonly
Write access is not required.
cefcFRUDrawnSystemCurrent readonly
Write access is not required.
cefcFRUTotalInlineCurrent readonly
Write access is not required.
cefcFRUDrawnInlineCurrent readonly
Write access is not required.
cefcModuleLocalSwitchingMode readonly
Write access is not required.
cefcIntelliModuleIPAddrType
ipv4(1)
An implementation is only required to
support IPv4 addresses.
Notifications / Traps (8)
NameOIDDescription
.1.3.6.1.4.1.9.9.117.2.0.1
This notification is generated when the value of
cefcModuleOperStatus changes. It can be utilized by
an NMS to update the status of the module it is
managing.
.1.3.6.1.4.1.9.9.117.2.0.2
The cefcFRUPowerStatusChange notification indicates that
the power status of a FRU has changed. The varbind for this
notification indicates the entPhysicalIndex of the FRU,
and the new operational-status of the FRU.
.1.3.6.1.4.1.9.9.117.2.0.3
The cecfFRUInserted notification indicates that a FRU was
inserted. The varbind for this notification indicates the
entPhysicalIndex of the inserted FRU, and the entPhysicalIndex
of the FRU's container.
.1.3.6.1.4.1.9.9.117.2.0.4
The cefcFRURemoved notification indicates that a FRU was
removed. The varbind for this notification indicates the
entPhysicalIndex of the removed FRU, and the entPhysicalIndex
of the FRU's container.
.1.3.6.1.4.1.9.9.117.2.0.5
The cefcUnrecognizedFRU notification indicates that a FRU was
inserted whose product ID is not supported. The varbind for
this notification indicates the entPhysicalIndex of the
inserted FRU, the entPhysicalClass this FRU belongs to, the
entPhysicalVendorType of this FRU, the entPhysicalName
of the FRU, the entPhysicalModelName of the inserted FRU, and
the cefcPhysicalStatus telling the reason code for sending this
notification.
.1.3.6.1.4.1.9.9.117.2.0.6
This notification is generated when the value of
cefcFanTrayOperStatus changes.
.1.3.6.1.4.1.9.9.117.2.0.7
The notification indicates that the power
supply's output capacity has changed.

This notification is triggered whenever one instance
of the power supply's cefcPSOutputModeInOperation
has transitioned from 'false' to 'true'.
.1.3.6.1.4.1.9.9.117.2.0.8
This notification is generated when the value of
cefcVmModuleOperStatus changes. It can be utilized by
an NMS to update the status of the module it is
managing.