CISCO-ENTITY-FRU-CONTROL-MIB
Monitored by Observium The CISCO-ENTITY-FRU-CONTROL-MIB is used to monitor
and configure operational status of
Field Replaceable Units (FRUs) and other managable
physical entities of the system listed in the
Entity-MIB (RFC 2737) entPhysicalTable.
FRUs include assemblies such as power supplies, fans,
processor modules, interface modules, etc.
Observium actively monitors this MIB
Observium uses this MIB in discovery or polling workflows on applicable devices.
Sensors
Explore Observium network monitoring
- Source file
CISCO-ENTITY-FRU-CONTROL-MIB- Last revised
- Identity
ciscoEntityFRUControlMIB- Base OID
1.3.6.1.4.1.9.9.117
Imported Objects
| CISCO-SMI | ciscoMgmt |
| ENTITY-MIB | entPhysicalClass entPhysicalContainedIn entPhysicalIndex entPhysicalModelName entPhysicalName entPhysicalVendorType |
| INET-ADDRESS-MIB | InetAddress InetAddressType |
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-CONF | MODULE-COMPLIANCE (no object page) NOTIFICATION-GROUP (no object page) OBJECT-GROUP (no object page) |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-TYPE (no object page) Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION (no object page) TimeStamp TruthValue |
Net-SNMP examples using the cisco MIB directory Show commands
These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.
Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'CISCO-ENTITY-FRU-CONTROL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CISCO-ENTITY-FRU-CONTROL-MIB::ciscoEntityFRUControlMIB'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-ENTITY-FRU-CONTROL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-ENTITY-FRU-CONTROL-MIB::ciscoEntityFRUControlMIB'
Objects (107)
16 directly used by Observium
Showing 107 of 107 objects
Object legend
Object type
Icons distinguish tables, entry rows, columns, scalars, and structural nodes.
SNMPv2-TCTruthValue
Syntax
Blue badges identify the value syntax. Connected badges read as defining module and convention.
IF-MIBifIndex
Table index
Green identifies an index object; yellow names its module when the index is defined elsewhere.
r/w
deprecated
obsolete
Access and status
r/w means read-write. Grey labels mark definitions retained for compatibility.
OBS ✓
Observium use
The indicator appears only when Observium directly references that object.
ifOperStatus
.1.3.6.1.2.1…
Names and OIDs
Object names link to their detail pages. Hover or focus a linked name or badge for available definition details.
.1.3.6.1.4.1.9.9.117 |
||
.1.3.6.1.4.1.9.9.117.1 |
||
.1.3.6.1.4.1.9.9.117.1.1 |
||
.1.3.6.1.4.1.9.9.117.1.1.1 |
||
.1.3.6.1.4.1.9.9.117.1.1.1.1 |
||
.1.3.6.1.4.1.9.9.117.1.1.1.1.1 |
||
|
|
.1.3.6.1.4.1.9.9.117.1.1.1.1.2 |
|
.1.3.6.1.4.1.9.9.117.1.1.1.1.3 |
||
|
|
.1.3.6.1.4.1.9.9.117.1.1.1.1.4 |
|
.1.3.6.1.4.1.9.9.117.1.1.1.1.5 |
||
|
Enumeration
|
.1.3.6.1.4.1.9.9.117.1.1.1.1.6 |
|
.1.3.6.1.4.1.9.9.117.1.1.1.1.7 |
||
.1.3.6.1.4.1.9.9.117.1.1.2 |
||
|
|
.1.3.6.1.4.1.9.9.117.1.1.2.1 |
|
|
|
.1.3.6.1.4.1.9.9.117.1.1.2.1.1 |
|
|
|
.1.3.6.1.4.1.9.9.117.1.1.2.1.2 |
|
.1.3.6.1.4.1.9.9.117.1.1.2.1.3 |
||
|
Bits
|
.1.3.6.1.4.1.9.9.117.1.1.2.1.4 |
|
.1.3.6.1.4.1.9.9.117.1.1.2.1.5 |
||
|
|
miliwattsInteger32
|
.1.3.6.1.4.1.9.9.117.1.1.3 |
.1.3.6.1.4.1.9.9.117.1.1.4 |
||
.1.3.6.1.4.1.9.9.117.1.1.4.1 |
||
.1.3.6.1.4.1.9.9.117.1.1.4.1.1 |
||
.1.3.6.1.4.1.9.9.117.1.1.4.1.2 |
||
.1.3.6.1.4.1.9.9.117.1.1.4.1.3 |
||
.1.3.6.1.4.1.9.9.117.1.1.4.1.4 |
||
.1.3.6.1.4.1.9.9.117.1.1.4.1.5 |
||
.1.3.6.1.4.1.9.9.117.1.1.4.1.6 |
||
|
miliwattsSNMPv2-SMIUnsigned32
|
.1.3.6.1.4.1.9.9.117.1.1.5 |
|
.1.3.6.1.4.1.9.9.117.1.2 |
||
.1.3.6.1.4.1.9.9.117.1.2.1 |
||
|
|
.1.3.6.1.4.1.9.9.117.1.2.1.1 |
|
|
|
.1.3.6.1.4.1.9.9.117.1.2.1.1.1 |
|
.1.3.6.1.4.1.9.9.117.1.2.1.1.10 |
||
|
|
.1.3.6.1.4.1.9.9.117.1.2.1.1.2 |
|
.1.3.6.1.4.1.9.9.117.1.2.1.1.3 |
||
.1.3.6.1.4.1.9.9.117.1.2.1.1.4 |
||
.1.3.6.1.4.1.9.9.117.1.2.1.1.5 |
||
.1.3.6.1.4.1.9.9.117.1.2.1.1.6 |
||
.1.3.6.1.4.1.9.9.117.1.2.1.1.7 |
||
.1.3.6.1.4.1.9.9.117.1.2.1.1.8 |
||
.1.3.6.1.4.1.9.9.117.1.2.1.1.9 |
||
.1.3.6.1.4.1.9.9.117.1.2.2 |
||
.1.3.6.1.4.1.9.9.117.1.2.2.1 |
||
.1.3.6.1.4.1.9.9.117.1.2.2.1.1 |
||
.1.3.6.1.4.1.9.9.117.1.2.2.1.2 |
||
.1.3.6.1.4.1.9.9.117.1.2.3 |
||
.1.3.6.1.4.1.9.9.117.1.2.3.1 |
||
|
Enumeration
|
.1.3.6.1.4.1.9.9.117.1.2.3.1.1 |
|
.1.3.6.1.4.1.9.9.117.1.3 |
||
.1.3.6.1.4.1.9.9.117.1.3.1 |
||
.1.3.6.1.4.1.9.9.117.1.3.2 |
||
.1.3.6.1.4.1.9.9.117.1.4 |
||
.1.3.6.1.4.1.9.9.117.1.4.1 |
||
|
|
.1.3.6.1.4.1.9.9.117.1.4.1.1 |
|
|
|
Enumeration
|
.1.3.6.1.4.1.9.9.117.1.4.1.1.1 |
|
Enumeration
|
.1.3.6.1.4.1.9.9.117.1.4.1.1.2 |
|
.1.3.6.1.4.1.9.9.117.1.4.2 |
||
|
|
.1.3.6.1.4.1.9.9.117.1.4.2.1 |
|
|
|
.1.3.6.1.4.1.9.9.117.1.4.2.1.1 |
|
|
|
percentCefcPercentOrMinusOne
|
.1.3.6.1.4.1.9.9.117.1.4.2.1.2 |
.1.3.6.1.4.1.9.9.117.1.5 |
||
.1.3.6.1.4.1.9.9.117.1.5.1 |
||
.1.3.6.1.4.1.9.9.117.1.5.1.1 |
||
|
Enumeration
|
.1.3.6.1.4.1.9.9.117.1.5.1.1.1 |
|
.1.3.6.1.4.1.9.9.117.1.6 |
||
.1.3.6.1.4.1.9.9.117.1.6.1 |
||
.1.3.6.1.4.1.9.9.117.1.6.1.1 |
||
.1.3.6.1.4.1.9.9.117.1.6.1.1.1 |
||
|
Enumeration
|
.1.3.6.1.4.1.9.9.117.1.6.1.1.2 |
|
.1.3.6.1.4.1.9.9.117.1.6.2 |
||
.1.3.6.1.4.1.9.9.117.1.6.2.1 |
||
.1.3.6.1.4.1.9.9.117.1.6.2.1.1 |
||
.1.3.6.1.4.1.9.9.117.1.6.2.1.2 |
||
.1.3.6.1.4.1.9.9.117.1.6.2.1.3 |
||
.1.3.6.1.4.1.9.9.117.1.7 |
||
.1.3.6.1.4.1.9.9.117.1.7.1 |
||
.1.3.6.1.4.1.9.9.117.1.7.1.1 |
||
.1.3.6.1.4.1.9.9.117.1.7.1.1.1 |
||
.1.3.6.1.4.1.9.9.117.1.7.1.1.2 |
||
.1.3.6.1.4.1.9.9.117.1.7.2 |
||
.1.3.6.1.4.1.9.9.117.1.7.2.1 |
||
.1.3.6.1.4.1.9.9.117.1.7.2.1.1 |
||
.1.3.6.1.4.1.9.9.117.1.7.2.1.2 |
||
.1.3.6.1.4.1.9.9.117.1.7.3 |
||
.1.3.6.1.4.1.9.9.117.1.7.3.1 |
||
.1.3.6.1.4.1.9.9.117.1.7.3.1.1 |
||
.1.3.6.1.4.1.9.9.117.1.7.3.1.2 |
||
.1.3.6.1.4.1.9.9.117.1.7.4 |
||
.1.3.6.1.4.1.9.9.117.1.7.4.1 |
||
|
Unsigned32
|
.1.3.6.1.4.1.9.9.117.1.7.4.1.1 |
|
.1.3.6.1.4.1.9.9.117.1.7.4.1.2 |
||
.1.3.6.1.4.1.9.9.117.1.7.4.1.3 |
||
.1.3.6.1.4.1.9.9.117.1.7.4.1.4 |
||
.1.3.6.1.4.1.9.9.117.1.7.4.1.5 |
||
.1.3.6.1.4.1.9.9.117.1.8 |
||
.1.3.6.1.4.1.9.9.117.1.8.1 |
||
.1.3.6.1.4.1.9.9.117.1.8.1.1 |
||
.1.3.6.1.4.1.9.9.117.1.8.1.1.1 |
||
.1.3.6.1.4.1.9.9.117.1.8.2 |
||
.1.3.6.1.4.1.9.9.117.1.8.2.1 |
||
.1.3.6.1.4.1.9.9.117.1.8.2.1.1 |
||
.1.3.6.1.4.1.9.9.117.2 |
||
.1.3.6.1.4.1.9.9.117.2.0 |
||
.1.3.6.1.4.1.9.9.117.3 |
||
.1.3.6.1.4.1.9.9.117.3.1 |
||
.1.3.6.1.4.1.9.9.117.3.2 |
Dependencies (9) 7 direct · 2 transitive Show tree and compile order Hide dependency details
Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.
Dependency tree
Dependency-first compile order
- SNMPv2-SMIrfc
- CISCO-SMIcisco
- SNMPv2-TCrfc
- IANA-ENTITY-MIBrfc
- SNMPv2-CONFrfc
- SNMP-FRAMEWORK-MIBrfc
- UUID-TC-MIBrfc
- ENTITY-MIBrfc
- INET-ADDRESS-MIBrfc
- CISCO-ENTITY-FRU-CONTROL-MIBciscoselected
Type Definitions (11)
| Integer32 |
range: -1..100 |
|
| Enumeration |
down(1)up(2)unknown(3)goingDown(4) |
|
| Enumeration |
cfm(1)watts(2) |
|
| Integer32 |
range: -1000000000..1000000000 |
|
| Unsigned32 | ||
| Enumeration |
enabled(1)disabled(2)reset(3)outOfServiceAdmin(4) |
|
| Enumeration |
unknown(1)ok(2)disabled(3)okButDiagFailed(4)boot(5)selfTest(6)failed(7)missing(8)mismatchWithParent(9)mismatchConfig(10)diagFailed(11)dormant(12)outOfServiceAdmin(13)outOfServiceEnvTemp(14)poweredDown(15)poweredUp(16)powerDenied(17)powerCycled(18)okButPowerOverWarning(19)okButPowerOverCritical(20)syncInProgress(21)upgrading(22)okButAuthFailed(23)mdr(24)fwMismatchFound(25)fwDownloadSuccess(26)fwDownloadFailure(27) |
|
| Enumeration |
unknown(1)powerUp(2)parityError(3)clearConfigReset(4)manualReset(5)watchDogTimeoutReset(6)resourceOverflowReset(7)missingTaskReset(8)lowVoltageReset(9)controllerReset(10)systemReset(11)switchoverReset(12)upgradeReset(13)downgradeReset(14)cacheErrorReset(15)deviceDriverReset(16)softwareExceptionReset(17)restoreConfigReset(18)abortRevReset(19)burnBootReset(20)standbyCdHealthierReset(21)nonNativeConfigClearReset(22)memoryProtectionErrorReset(23) |
|
| Enumeration |
on(1)off(2)inlineAuto(3)inlineOn(4)powerCycle(5) |
|
| Enumeration |
offEnvOther(1)on(2)offAdmin(3)offDenied(4)offEnvPower(5)offEnvTemp(6)offEnvFan(7)failed(8)onButFanFail(9)offCooling(10)offConnectorRating(11)onButInlinePowerFail(12) |
|
| Enumeration |
notsupported(1)redundant(2)combined(3)nonRedundant(4)psRedundant(5)inPwrSrcRedundant(6)psRedundantSingleInput(7) |
Conformance Groups (35)
|
The collection of objects which are used
to configure and monitor power-control for FRUs. |
.1.3.6.1.4.1.9.9.117.3.2.1
|
|
|
The collection of objects which are used
to configure and monitor power-control for FRUs. |
.1.3.6.1.4.1.9.9.117.3.2.2
|
|
|
The collection of objects which are used to get the
operational state and redundancy state of the modules |
.1.3.6.1.4.1.9.9.117.3.2.3
|
|
|
cefcMIBInLinePowerControlGroup
deprecated
|
The collection of objects which are used to
configure and monitor inline power control for FRUs. |
.1.3.6.1.4.1.9.9.117.3.2.4
|
|
The collection of objects which are used to
enable notification. |
.1.3.6.1.4.1.9.9.117.3.2.5
|
|
|
The notifications which a FRU Management entity is
required to implement. |
.1.3.6.1.4.1.9.9.117.3.2.6
|
|
|
The collection of objects which are used to get the
operational state and redundancy state of the modules |
.1.3.6.1.4.1.9.9.117.3.2.7
|
|
|
cefcFRUTotalSystemCurrent cefcFRUDrawnSystemCurrent cefcFRUTotalInlineCurrent cefcFRUDrawnInlineCurrent
The collection of objects which are used to retrieve
the total and used capacity of a power supply for both system and inline power. |
.1.3.6.1.4.1.9.9.117.3.2.8
|
|
|
The collection of objects which show information of the
status of Fan Tray FRUs. |
.1.3.6.1.4.1.9.9.117.3.2.9
|
|
|
The collection of objects which show information of the
Physical Entity. |
.1.3.6.1.4.1.9.9.117.3.2.10
|
|
|
The additional notifications for FRU status.
|
.1.3.6.1.4.1.9.9.117.3.2.11
|
|
|
The collection of objects which are used
to monitor the device's power supply operational redundancy mode. |
.1.3.6.1.4.1.9.9.117.3.2.12
|
|
|
The collection of objects which are used to
configure and monitor inline power control for FRUs. |
.1.3.6.1.4.1.9.9.117.3.2.13
|
|
|
The collection of objects which are used to get the
state change reason and up time of the modules. |
.1.3.6.1.4.1.9.9.117.3.2.14
|
|
|
The collection of objects which are used to get the
information specific to intelligent modules. |
.1.3.6.1.4.1.9.9.117.3.2.15
|
|
|
The collection of objects which are used to get the
power capacity information |
.1.3.6.1.4.1.9.9.117.3.2.16
|
|
|
cefcCoolingGroup
deprecated
|
The collection of objects which are used to get the
cooling capacity information. |
.1.3.6.1.4.1.9.9.117.3.2.17
|
|
The collection of objects which are used to get the
power connector rating and module power total consumption information. |
.1.3.6.1.4.1.9.9.117.3.2.18
|
|
|
The collection of objects which are used to
enable additional group of notifications. |
.1.3.6.1.4.1.9.9.117.3.2.19
|
|
|
The additional notification for notify the
power capacity mode change. |
.1.3.6.1.4.1.9.9.117.3.2.20
|
|
|
The collection of objects which are used to
monitor inline power usage for FRUs. |
.1.3.6.1.4.1.9.9.117.3.2.21
|
|
|
The collection of objects provide additional
information about the device's power supply redundancy. |
.1.3.6.1.4.1.9.9.117.3.2.22
|
|
|
The collection of objects provide the cooling
capacity modes and properties of the fans. |
.1.3.6.1.4.1.9.9.117.3.2.23
|
|
|
The collection of objects which show information of the
local switching status of modules. |
.1.3.6.1.4.1.9.9.117.3.2.24
|
|
|
The collection of objects provide the power-related
realtime information of the manageable entities. |
.1.3.6.1.4.1.9.9.117.3.2.25
|
|
|
The collection of objects provide the power-related
capability information of the manageable entities. |
.1.3.6.1.4.1.9.9.117.3.2.26
|
|
|
The collection of objects provide the cooling unit
information of the manageable entities. |
.1.3.6.1.4.1.9.9.117.3.2.27
|
|
|
The collection of objects provide the cooling unit
information of the manageable fan entities. |
.1.3.6.1.4.1.9.9.117.3.2.28
|
|
|
The collection of objects which are used to get the
cooling capacity or requirement information. |
.1.3.6.1.4.1.9.9.117.3.2.29
|
|
|
The collection of objects provide the cooling
capacity modes and properties of the fans. |
.1.3.6.1.4.1.9.9.117.3.2.30
|
|
|
The collection of objects provide the direction
information of the manageable fan entities. |
.1.3.6.1.4.1.9.9.117.3.2.31
|
|
|
The collection of objects provide the speed
information of the manageable fan entities. |
.1.3.6.1.4.1.9.9.117.3.2.32
|
|
|
The collection of objects which are used to retrieve
the actual input and output current of a power supply. |
.1.3.6.1.4.1.9.9.117.3.2.33
|
|
|
The collection of objects which povide the VM
module opertional status information. |
.1.3.6.1.4.1.9.9.117.3.2.34
|
|
|
A collection of notifications for VM module
status change. |
.1.3.6.1.4.1.9.9.117.3.2.35
|
Compliance Statements (10)
OID
.1.3.6.1.4.1.9.9.117.3.1.1An Entity-MIB implementation can implement this group to
provide FRU power status and control.
provide FRU power status and control.
Required groups
| mandatory | cefcMIBPowerModeGroup | |
| optional | cefcMIBPowerFRUControlGroup |
The cefcMIBPowerFRUControlGroup must be implemented for FRUs that have power control |
OID
.1.3.6.1.4.1.9.9.117.3.1.2An Entity-MIB implementation can implement this group to
provide FRU power status and control.
provide FRU power status and control.
Required groups
| mandatory | cefcMIBPowerModeGroup | |
| mandatory | cefcMgmtNotificationsGroup | |
| optional | cefcMIBPowerFRUControlGroup |
The cefcMIBPowerFRUControlGroup must be implemented for FRUs that have power control |
| optional | cefcMIBModuleGroup |
The cefcMIBModuleGroup must be implemented for FRUs that are of module type. |
| optional | cefcMIBInLinePowerControlGroup |
The cefcMIBInLinePowerControlGroup must be implemented for FRUs that have inline power control |
| optional | cefcMIBNotificationEnablesGroup |
The cefcMIBNotificationEnablesGroup must be implemented for FRUs that have notification |
OID
.1.3.6.1.4.1.9.9.117.3.1.3An Entity-MIB implementation can implement this group to
provide FRU power status and control.
provide FRU power status and control.
Required groups
| mandatory | cefcMIBPowerModeGroup | |
| mandatory | cefcMgmtNotificationsGroup | |
| optional | cefcMIBPowerFRUControlGroup |
The cefcMIBPowerFRUControlGroup must be implemented for FRUs that have power control |
| optional | cefcMIBModuleGroup |
The cefcMIBModuleGroup must be implemented for FRUs that are of module type. |
| optional | cefcMIBInLinePowerControlGroup |
The cefcMIBInLinePowerControlGroup must be implemented for FRUs that have inline power control |
| optional | cefcMIBNotificationEnablesGroup |
The cefcMIBNotificationEnablesGroup must be implemented for FRUs that have notification |
| optional | cefcModuleGroupRev1 |
The cefcModuleGroupRev1 is not mandatory for agents with FRUs that are of module type. |
OID
.1.3.6.1.4.1.9.9.117.3.1.4An Entity-MIB implementation can implement this group to
provide FRU power status and control.
provide FRU power status and control.
Required groups
| mandatory | cefcMIBPowerModeGroup | |
| mandatory | cefcMgmtNotificationsGroup | |
| optional | cefcMIBPowerFRUControlGroup |
The cefcMIBPowerFRUControlGroup must be implemented for FRUs that have power control |
| optional | cefcMIBModuleGroup |
The cefcMIBModuleGroup must be implemented for FRUs that are of module type. |
| optional | cefcMIBInLinePowerControlGroup |
The cefcMIBInLinePowerControlGroup must be implemented for FRUs that have inline power control |
| optional | cefcMIBNotificationEnablesGroup |
The cefcMIBNotificationEnablesGroup must be implemented for FRUs that have notification |
| optional | cefcModuleGroupRev1 |
The cefcModuleGroupRev1 is not mandatory for agents with FRUs that are of module type. |
| optional | cefcMIBPowerFRUValueGroup |
The cefcMIBPowerFRUValueGroup must be implemented for power supply FRUs that have variable output |
Object refinements
| Object | Access | Syntax | Description |
|---|---|---|---|
| cefcFRUTotalSystemCurrent | readonly | Write access is not required. | |
| cefcFRUDrawnSystemCurrent | readonly | Write access is not required. | |
| cefcFRUTotalInlineCurrent | readonly | Write access is not required. | |
| cefcFRUDrawnInlineCurrent | readonly | Write access is not required. |
OID
.1.3.6.1.4.1.9.9.117.3.1.5An Entity-MIB implementation can implement this group to
provide FRU power status and control.
provide FRU power status and control.
Required groups
| mandatory | cefcMIBPowerModeGroup | |
| mandatory | cefcMgmtNotificationsGroup | |
| mandatory | cefcMgmtNotificationsGroup2 | |
| optional | cefcMIBPowerFRUControlGroup |
The cefcMIBPowerFRUControlGroup must be implemented for FRUs that have power control |
| optional | cefcMIBModuleGroup |
The cefcMIBModuleGroup must be implemented for FRUs that are of module type. |
| optional | cefcMIBInLinePowerControlGroup |
The cefcMIBInLinePowerControlGroup must be implemented for FRUs that have inline power control |
| optional | cefcMIBNotificationEnablesGroup |
The cefcMIBNotificationEnablesGroup must be implemented for FRUs that have notification |
| optional | cefcModuleGroupRev1 |
The cefcModuleGroupRev1 is not mandatory for agents with FRUs that are of module type. |
| optional | cefcMIBPowerFRUValueGroup |
The cefcMIBPowerFRUValueGroup must be implemented for power supply FRUs that have variable output |
| optional | cefcMIBFanTrayStatusGroup |
The cefcMIBFanTrayStatusGroup must be implemented in all systems which can detect the status of Fan Tray FRUs. |
| optional | cefcMIBPhysicalGroup |
The collection of objects which show information of the Physical Entity. |
Object refinements
| Object | Access | Syntax | Description |
|---|---|---|---|
| cefcFRUTotalSystemCurrent | readonly | Write access is not required. | |
| cefcFRUDrawnSystemCurrent | readonly | Write access is not required. | |
| cefcFRUTotalInlineCurrent | readonly | Write access is not required. | |
| cefcFRUDrawnInlineCurrent | readonly | Write access is not required. |
OID
.1.3.6.1.4.1.9.9.117.3.1.6An Entity-MIB implementation can implement this group to
provide FRU power status and control.
provide FRU power status and control.
Required groups
| mandatory | cefcMIBPowerModeGroup | |
| mandatory | cefcMgmtNotificationsGroup | |
| optional | cefcMIBPowerFRUControlGroup |
The cefcMIBPowerFRUControlGroup must be implemented for FRUs that have power control |
| optional | cefcMIBModuleGroup |
The cefcMIBModuleGroup must be implemented for FRUs that are of module type. |
| optional | cefcMIBInLinePowerControlGroupRev1 |
The cefcMIBInLinePowerControlGroup must be implemented for FRUs that have inline power control |
| optional | cefcMIBNotificationEnablesGroup |
The cefcMIBNotificationEnablesGroup must be implemented for FRUs that have notification |
| optional | cefcModuleGroupRev1 |
The cefcModuleGroupRev1 is not mandatory for agents with FRUs that are of module type. |
| optional | cefcMIBPowerFRUValueGroup |
The cefcMIBPowerFRUValueGroup must be implemented for power supply FRUs that have variable output |
| optional | cefcMIBFanTrayStatusGroup |
The cefcMIBFanTrayStatusGroup must be implemented in all systems which can detect the status of Fan Tray FRUs. |
| optional | cefcMIBPhysicalGroup |
The collection of objects which show information of the Physical Entity. |
| optional | cefcMgmtNotificationsGroup2 |
The implementation of this group of notifications is optional. |
| optional | cefcMIBPowerOperModeGroup |
The cefcMIBPowerOperModeGroup must be implemented for the device which supports power supply operational modes. |
| optional | cefcModuleExtGroup |
Implementation of cefcModuleExtGroup is optional. |
| optional | cefcIntelliModuleGroup |
Implementation of cefcModuleAddrGroup is optional. |
Object refinements
| Object | Access | Syntax | Description |
|---|---|---|---|
| cefcFRUTotalSystemCurrent | readonly | Write access is not required. | |
| cefcFRUDrawnSystemCurrent | readonly | Write access is not required. | |
| cefcFRUTotalInlineCurrent | readonly | Write access is not required. | |
| cefcFRUDrawnInlineCurrent | readonly | Write access is not required. | |
| cefcIntelliModuleIPAddrType |
ipv4(1)
|
An implementation is only required to support IPv4 addresses. |
OID
.1.3.6.1.4.1.9.9.117.3.1.7An Entity-MIB implementation can implement this group to
provide FRU power status and control.
provide FRU power status and control.
Required groups
| mandatory | cefcMIBPowerModeGroup | |
| mandatory | cefcMgmtNotificationsGroup | |
| optional | cefcMIBPowerFRUControlGroup |
The cefcMIBPowerFRUControlGroup must be implemented for FRUs that have power control |
| optional | cefcMIBModuleGroup |
The cefcMIBModuleGroup must be implemented for FRUs that are of module type. |
| optional | cefcMIBInLinePowerControlGroupRev1 |
The cefcMIBInLinePowerControlGroup must be implemented for FRUs that have inline power control |
| optional | cefcMIBNotificationEnablesGroup |
The cefcMIBNotificationEnablesGroup must be implemented for FRUs that have notification |
| optional | cefcModuleGroupRev1 |
The cefcModuleGroupRev1 is not mandatory for agents with FRUs that are of module type. |
| optional | cefcMIBPowerFRUValueGroup |
The cefcMIBPowerFRUValueGroup must be implemented for power supply FRUs that have variable output |
| optional | cefcMIBFanTrayStatusGroup |
The cefcMIBFanTrayStatusGroup must be implemented in all systems which can detect the status of Fan Tray FRUs. |
| optional | cefcMIBPhysicalGroup |
The collection of objects which show information of the Physical Entity. |
| optional | cefcMgmtNotificationsGroup2 |
The implementation of this group of notifications is optional. |
| optional | cefcMIBPowerOperModeGroup |
The cefcMIBPowerOperModeGroup must be implemented for the device which supports power supply operational modes. |
| optional | cefcModuleExtGroup |
Implementation of cefcModuleExtGroup is optional. |
| optional | cefcIntelliModuleGroup |
Implementation of cefcModuleAddrGroup is optional. |
| optional | cefcPowerCapacityGroup |
This group is mandatory for devices which have the capability to populate power capacity information. |
| optional | cefcCoolingGroup |
This group is mandatory for devices which have the capability to populate cooling capacity information. |
| optional | cefcConnectorRatingGroup |
This group is mandatory for devices which have the capability to populate power connector rating and module power total consumption information. |
| optional | cefcMIBNotificationEnablesGroup2 |
This group is mandatory for devices which support the SNMP notification to notify the power supply output capacity changes. |
| optional | cefcMgmtNotificationsGroup3 |
This group is mandatory for devices which support the SNMP notification to notify the power supply output capacity changes. |
Object refinements
| Object | Access | Syntax | Description |
|---|---|---|---|
| cefcFRUTotalSystemCurrent | readonly | Write access is not required. | |
| cefcFRUDrawnSystemCurrent | readonly | Write access is not required. | |
| cefcFRUTotalInlineCurrent | readonly | Write access is not required. | |
| cefcFRUDrawnInlineCurrent | readonly | Write access is not required. | |
| cefcIntelliModuleIPAddrType |
ipv4(1)
|
An implementation is only required to support IPv4 addresses. |
OID
.1.3.6.1.4.1.9.9.117.3.1.8An Entity-MIB implementation can implement this group to
provide FRU power status and control.
provide FRU power status and control.
Required groups
| mandatory | cefcMIBPowerModeGroup | |
| mandatory | cefcMgmtNotificationsGroup | |
| optional | cefcMIBPowerFRUControlGroup |
The cefcMIBPowerFRUControlGroup must be implemented for FRUs that have power control |
| optional | cefcMIBModuleGroup |
The cefcMIBModuleGroup must be implemented for FRUs that are of module type. |
| optional | cefcMIBInLinePowerControlGroupRev1 |
The cefcMIBInLinePowerControlGroup must be implemented for FRUs that have inline power control |
| optional | cefcMIBNotificationEnablesGroup |
The cefcMIBNotificationEnablesGroup must be implemented for FRUs that have notification |
| optional | cefcModuleGroupRev1 |
The cefcModuleGroupRev1 is not mandatory for agents with FRUs that are of module type. |
| optional | cefcMIBPowerFRUValueGroup |
The cefcMIBPowerFRUValueGroup must be implemented for power supply FRUs that have variable output |
| optional | cefcMIBFanTrayStatusGroup |
The cefcMIBFanTrayStatusGroup must be implemented in all systems which can detect the status of Fan Tray FRUs. |
| optional | cefcMIBPhysicalGroup |
The collection of objects which show information of the Physical Entity. |
| optional | cefcMgmtNotificationsGroup2 |
The implementation of this group of notifications is optional. |
| optional | cefcMIBPowerOperModeGroup |
The cefcMIBPowerOperModeGroup must be implemented for the device which supports power supply operational modes. |
| optional | cefcModuleExtGroup |
Implementation of cefcModuleExtGroup is optional. |
| optional | cefcIntelliModuleGroup |
Implementation of cefcModuleAddrGroup is optional. |
| optional | cefcPowerCapacityGroup |
This group is mandatory for devices which have the capability to populate power capacity information. |
| optional | cefcCoolingGroup |
This group is mandatory for devices which have the capability to populate cooling capacity information. |
| optional | cefcConnectorRatingGroup |
This group is mandatory for devices which have the capability to populate power connector rating and module power total consumption information. |
| optional | cefcMIBNotificationEnablesGroup2 |
This group is mandatory for devices which support the SNMP notification to notify the power supply output capacity changes. |
| optional | cefcMgmtNotificationsGroup3 |
This group is mandatory for devices which support the SNMP notification to notify the power supply output capacity changes. |
| optional | cefcMIBInLinePowerCurrentGroup |
This group is mandatory for devices which have the capability to populate inline power usage information. |
| optional | cefcMIBPowerRedundancyInfoGroup |
This group is mandatory for devices which have the capability to populate the reason why the redundancy of the power supplies cannot be achieved. |
| optional | cefcFanCoolingCapGroup |
This group is mandatory for devices which can provide the cooling capacity modes and properties of the fans in the system. |
Object refinements
| Object | Access | Syntax | Description |
|---|---|---|---|
| cefcFRUTotalSystemCurrent | readonly | Write access is not required. | |
| cefcFRUDrawnSystemCurrent | readonly | Write access is not required. | |
| cefcFRUTotalInlineCurrent | readonly | Write access is not required. | |
| cefcFRUDrawnInlineCurrent | readonly | Write access is not required. | |
| cefcIntelliModuleIPAddrType |
ipv4(1)
|
An implementation is only required to support IPv4 addresses. |
OID
.1.3.6.1.4.1.9.9.117.3.1.9An Entity-MIB implementation can implement this group to
provide FRU power status and control.
provide FRU power status and control.
Required groups
| mandatory | cefcMIBPowerModeGroup | |
| mandatory | cefcMgmtNotificationsGroup | |
| optional | cefcMIBPowerFRUControlGroup |
The cefcMIBPowerFRUControlGroup must be implemented for FRUs that have power control |
| optional | cefcMIBModuleGroup |
The cefcMIBModuleGroup must be implemented for FRUs that are of module type. |
| optional | cefcMIBInLinePowerControlGroupRev1 |
The cefcMIBInLinePowerControlGroup must be implemented for FRUs that have inline power control |
| optional | cefcMIBNotificationEnablesGroup |
The cefcMIBNotificationEnablesGroup must be implemented for FRUs that have notification |
| optional | cefcModuleGroupRev1 |
The cefcModuleGroupRev1 is not mandatory for agents with FRUs that are of module type. |
| optional | cefcMIBPowerFRUValueGroup |
The cefcMIBPowerFRUValueGroup must be implemented for power supply FRUs that have variable output |
| optional | cefcMIBFanTrayStatusGroup |
The cefcMIBFanTrayStatusGroup must be implemented in all systems which can detect the status of Fan Tray FRUs. |
| optional | cefcMIBPhysicalGroup |
The collection of objects which show information of the Physical Entity. |
| optional | cefcMgmtNotificationsGroup2 |
The implementation of this group of notifications is optional. |
| optional | cefcMIBPowerOperModeGroup |
The cefcMIBPowerOperModeGroup must be implemented for the device which supports power supply operational modes. |
| optional | cefcModuleExtGroup |
Implementation of cefcModuleExtGroup is optional. |
| optional | cefcIntelliModuleGroup |
Implementation of cefcModuleAddrGroup is optional. |
| optional | cefcPowerCapacityGroup |
This group is mandatory for devices which have the capability to populate power capacity information. |
| optional | cefcConnectorRatingGroup |
This group is mandatory for devices which have the capability to populate power connector rating and module power total consumption information. |
| optional | cefcMIBNotificationEnablesGroup2 |
This group is mandatory for devices which support the SNMP notification to notify the power supply output capacity changes. |
| optional | cefcMgmtNotificationsGroup3 |
This group is mandatory for devices which support the SNMP notification to notify the power supply output capacity changes. |
| optional | cefcMIBInLinePowerCurrentGroup |
This group is mandatory for devices which have the capability to populate inline power usage information. |
| optional | cefcMIBPowerRedundancyInfoGroup |
This group is mandatory for devices which have the capability to populate the reason why the redundancy of the power supplies cannot be achived. |
| optional | cefcFanCoolingCapGroup |
This group is mandatory for devices which can provide the cooling capacity modes and properties of the fans in the system. |
| optional | cefcMIBModuleLocalSwitchingGroup |
This group is mandatory for devices which support modules with local switching functionality. |
| optional | cefcFRUPowerRealTimeStatusGroup |
This group is mandatory for devices which support power related realtime status. |
| optional | cefcFRUPowerCapabilityGroup |
This group is mandatory for devices which support power related capability information. |
| optional | cefcFRUCoolingUnitGroup |
This group is mandatory for devices which support the cooling unit information. |
| optional | cefcFRUFanCoolingUnitGroup |
This group is mandatory for devices which support the fan capacity cooling unit information. |
| optional | cefcCoolingGroup2 |
This group is mandatory for devices which support the chassis cooling capacity and module cooling requirement. |
| optional | cefcFanCoolingGroup |
This group is mandatory for devices which support the fan cooling capacity information. |
Object refinements
| Object | Access | Syntax | Description |
|---|---|---|---|
| cefcFRUTotalSystemCurrent | readonly | Write access is not required. | |
| cefcFRUDrawnSystemCurrent | readonly | Write access is not required. | |
| cefcFRUTotalInlineCurrent | readonly | Write access is not required. | |
| cefcFRUDrawnInlineCurrent | readonly | Write access is not required. | |
| cefcModuleLocalSwitchingMode | readonly | Write access is not required. | |
| cefcIntelliModuleIPAddrType |
ipv4(1)
|
An implementation is only required to support IPv4 addresses. |
OID
.1.3.6.1.4.1.9.9.117.3.1.10An Entity-MIB implementation can implement this group to
provide FRU power status and control.
provide FRU power status and control.
Required groups
| mandatory | cefcMIBPowerModeGroup | |
| mandatory | cefcMgmtNotificationsGroup | |
| optional | cefcMIBPowerFRUControlGroup |
The cefcMIBPowerFRUControlGroup must be implemented for FRUs that have power control |
| optional | cefcMIBModuleGroup |
The cefcMIBModuleGroup must be implemented for FRUs that are of module type. |
| optional | cefcMIBInLinePowerControlGroupRev1 |
The cefcMIBInLinePowerControlGroup must be implemented for FRUs that have inline power control |
| optional | cefcMIBNotificationEnablesGroup |
The cefcMIBNotificationEnablesGroup must be implemented for FRUs that have notification |
| optional | cefcModuleGroupRev1 |
The cefcModuleGroupRev1 is not mandatory for agents with FRUs that are of module type. |
| optional | cefcMIBPowerFRUValueGroup |
The cefcMIBPowerFRUValueGroup must be implemented for power supply FRUs that have variable output |
| optional | cefcMIBFanTrayStatusGroup |
The cefcMIBFanTrayStatusGroup must be implemented in all systems which can detect the status of Fan Tray FRUs. |
| optional | cefcMIBPhysicalGroup |
The collection of objects which show information of the Physical Entity. |
| optional | cefcMgmtNotificationsGroup2 |
The implementation of this group of notifications is optional. |
| optional | cefcMIBPowerOperModeGroup |
The cefcMIBPowerOperModeGroup must be implemented for the device which supports power supply operational modes. |
| optional | cefcModuleExtGroup |
Implementation of cefcModuleExtGroup is optional. |
| optional | cefcIntelliModuleGroup |
Implementation of cefcModuleAddrGroup is optional. |
| optional | cefcPowerCapacityGroup |
This group is mandatory for devices which have the capability to populate power capacity information. |
| optional | cefcConnectorRatingGroup |
This group is mandatory for devices which have the capability to populate power connector rating and module power total consumption information. |
| optional | cefcMIBNotificationEnablesGroup2 |
This group is mandatory for devices which support the SNMP notification to notify the power supply output capacity changes. |
| optional | cefcMgmtNotificationsGroup3 |
This group is mandatory for devices which support the SNMP notification to notify the power supply output capacity changes. |
| optional | cefcMIBInLinePowerCurrentGroup |
This group is mandatory for devices which have the capability to populate inline power usage information. |
| optional | cefcMIBPowerRedundancyInfoGroup |
This group is mandatory for devices which have the capability to populate the reason why the redundancy of the power supplies cannot be achived. |
| optional | cefcFanCoolingCapGroup |
This group is mandatory for devices which can provide the cooling capacity modes and properties of the fans in the system. |
| optional | cefcMIBModuleLocalSwitchingGroup |
This group is mandatory for devices which support modules with local switching functionality. |
| optional | cefcFRUPowerRealTimeStatusGroup |
This group is mandatory for devices which support power related realtime status. |
| optional | cefcFRUPowerCapabilityGroup |
This group is mandatory for devices which support power related capability information. |
| optional | cefcFRUCoolingUnitGroup |
This group is mandatory for devices which support the cooling unit information. |
| optional | cefcFRUFanCoolingUnitGroup |
This group is mandatory for devices which support the fan capacity cooling unit information. |
| optional | cefcCoolingGroup2 |
This group is mandatory for devices which support the chassis cooling capacity and module cooling requirement. |
| optional | cefcFanCoolingGroup |
This group is mandatory for devices which support the fan cooling capacity information. |
| optional | cefcFanDirectionGroup |
This group is mandatory for devices which support fan direction. |
| optional | cefcFanSpeedGroup |
This group is mandatory for devices which support fan speed. |
| optional | cefcPowerSupplyActualGroup |
This group is mandatory for devices which support actual input and output current of a power supply. |
| optional | cefcVmModuleGroup |
This group is mandatory for devices which support VM module status. |
| optional | cefcVmModuleNotifsGroup |
This group is mandatory for devices which support VM module status notifications. |
Object refinements
| Object | Access | Syntax | Description |
|---|---|---|---|
| cefcFRUTotalSystemCurrent | readonly | Write access is not required. | |
| cefcFRUDrawnSystemCurrent | readonly | Write access is not required. | |
| cefcFRUTotalInlineCurrent | readonly | Write access is not required. | |
| cefcFRUDrawnInlineCurrent | readonly | Write access is not required. | |
| cefcModuleLocalSwitchingMode | readonly | Write access is not required. | |
| cefcIntelliModuleIPAddrType |
ipv4(1)
|
An implementation is only required to support IPv4 addresses. |
Notifications / Traps (8)
| Name | OID | Description |
|---|---|---|
.1.3.6.1.4.1.9.9.117.2.0.1 |
This notification is generated when the value of
cefcModuleOperStatus changes. It can be utilized by an NMS to update the status of the module it is managing. |
|
.1.3.6.1.4.1.9.9.117.2.0.2 |
The cefcFRUPowerStatusChange notification indicates that
the power status of a FRU has changed. The varbind for this notification indicates the entPhysicalIndex of the FRU, and the new operational-status of the FRU. |
|
.1.3.6.1.4.1.9.9.117.2.0.3 |
The cecfFRUInserted notification indicates that a FRU was
inserted. The varbind for this notification indicates the entPhysicalIndex of the inserted FRU, and the entPhysicalIndex of the FRU's container. |
|
.1.3.6.1.4.1.9.9.117.2.0.4 |
The cefcFRURemoved notification indicates that a FRU was
removed. The varbind for this notification indicates the entPhysicalIndex of the removed FRU, and the entPhysicalIndex of the FRU's container. |
|
.1.3.6.1.4.1.9.9.117.2.0.5 |
The cefcUnrecognizedFRU notification indicates that a FRU was
inserted whose product ID is not supported. The varbind for this notification indicates the entPhysicalIndex of the inserted FRU, the entPhysicalClass this FRU belongs to, the entPhysicalVendorType of this FRU, the entPhysicalName of the FRU, the entPhysicalModelName of the inserted FRU, and the cefcPhysicalStatus telling the reason code for sending this notification. |
|
.1.3.6.1.4.1.9.9.117.2.0.6 |
This notification is generated when the value of
cefcFanTrayOperStatus changes. |
|
.1.3.6.1.4.1.9.9.117.2.0.7 |
The notification indicates that the power
supply's output capacity has changed. This notification is triggered whenever one instance of the power supply's cefcPSOutputModeInOperation has transitioned from 'false' to 'true'. |
|
.1.3.6.1.4.1.9.9.117.2.0.8 |
This notification is generated when the value of
cefcVmModuleOperStatus changes. It can be utilized by an NMS to update the status of the module it is managing. |