zxAnXdsl2LConfUpboU3bandKLRef

ZTE-AN-XDSL2-MIBII · .1.3.6.1.4.1.3902.1015.1001.1.3.14.1.14

Object

column r/w 0.1 dB SNMPv2-SMIUnsigned32
This parameter defines the UPBO reference electrical length used to 
compute the upstream power back-off for each upstream band except US0, 
for the optional Equalized FEXT UPBO method. The value ranges from 
1.8 to 63.5 dB in steps of 0.1 dB with special value 0. 
The use of the special value 0 is described in 7.2.1.3.2/G.993.2.

Context

MIB
ZTE-AN-XDSL2-MIBII
OID
.1.3.6.1.4.1.3902.1015.1001.1.3.14.1.14
Type
column
Access
readwrite
Status
current
Units
0.1 dB
Parent
zxAnXdsl2UpboConfPrfEntry
Table
zxAnXdsl2UpboConfPrfTable
Siblings
15

Syntax

0.1 dB SNMPv2-SMIUnsigned32
Source
SNMPv2-SMIUnsigned32
Base type
Unsigned32

Values & Constraints

Type Constraints
range: 0..4294967295

Related Objects

Sibling Objects