zxAnEthOamErrFrameSecsSummaryThreshold

ZTE-AN-ETH-EFM-MIB · .1.3.6.1.4.1.3902.1015.61.5.1.13

Object

column r/w errored frame seconds Integer32
The number of errored frame seconds that must occur for this event to be triggered. 
The default value is one errored frame second. If the threshold value is zero, then 
an Event Notification OAMPDU is sent periodically (at the end of every window). 
This can be used as an asynchronous notification to the peer OAM entity of the 
statistics related to this threshold crossing alarm. If OamErrFrameSecsSummaryThreshold 
frame errors occur within a window of OamErrFrameSecsSummaryWindow (in tenths of 
seconds), an Event Notification OAMPDU should be generated with an Errored Frame 
Seconds Summary Event TLV indicating the threshold has been crossed in this window.

Context

MIB
ZTE-AN-ETH-EFM-MIB
OID
.1.3.6.1.4.1.3902.1015.61.5.1.13
Type
column
Access
readwrite
Status
current
Units
errored frame seconds
Parent
zxAnEthOamEventConfigEntry
Table
zxAnEthOamEventConfigTable
Siblings
15

Syntax

errored frame seconds Integer32

Values & Constraints

Object Constraints
range: 1-900

Related Objects

Sibling Objects