sechtor100RowStatus
ZHONE-SECHTOR100-MIB ·
.1.3.6.1.4.1.5504.2.4.1.3.1.12
Object
Used to control row creation and deletion.
A row in this table is created using a single
SNMP SET request with varbinds for:
a) sechtor100RowStatus set to'CreateAndGo',
b) the following READ-CREATE object(s):
*
If 'createAndGo' successfully created a new row,
the RowStatus will be 'active'. Subsequent to
successful row creation, the RowStatus can be
retrieved via an SNMP GET and the returned
RowStatus value is active. If the 'createAndGo'
was unsuccessful an SNMP error will be returned
and a subsequent GET on the non-existent row
will also return an SNMP error of noSuchInstance.
An SNMP SET with the RowStatus value of 'destroy'
indicates that the agent should remove the row
from service and then delete it.
Context
- MIB
- ZHONE-SECHTOR100-MIB
- OID
.1.3.6.1.4.1.5504.2.4.1.3.1.12- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- sechtor100ConfigEntry
- Table
- sechtor100ConfigTable
- Siblings
- 11
Values & Constraints
Type Values
1 | active |
4 | createAndGo |
6 | destroy |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| sechtor100PeerMacAddress This is the Mac address of the peer s100 unit. | column | SNMPv2-TCMacAddress | .1.3.6.1.4.1.5504.2.4.1.3.1.1 |
| sechtor100ThermoAOperationalStatus The operational status indicator for thermometer A.
Valid values are:
* withinOperationalRange - s100ThermoATemperature is within
its lower and upper threshold ra… | column | Enumeration | .1.3.6.1.4.1.5504.2.4.1.3.1.10 |
| sechtor100ThermoBOperationalStatus The operational status indicator for thermometer B.
Valid values are:
* withinOperationalRange - s100ThermoBTemperature is within
its lower and upper threshold ra… | column | Enumeration | .1.3.6.1.4.1.5504.2.4.1.3.1.11 |
| sechtor100RedundancyEnable Whether or not the redundancy functionality has been enabled.
If this value is false, redundancy is not enable. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.5504.2.4.1.3.1.2 |
| sechtor100FanOperationalStatus This variable describes the working status of the four fans
for the Sechtor 100. If any one of the four fans is not
running correctly, this variable shows 'fanFailure'. When
all t… | column | Enumeration | .1.3.6.1.4.1.5504.2.4.1.3.1.3 |
| sechtor100ThermoAUpperThreshold This variable specifies the upper threshold for thermometer
A in degrees Celsius. When s100ThermoATemperature is
above this value, s100ThermoAOperationalStatus would be
'overUpper… | column | Integer32 | .1.3.6.1.4.1.5504.2.4.1.3.1.4 |
| sechtor100ThermoBUpperThreshold This variable specifies the upper threshold for thermometer
B in degrees Celsius. When s100ThermoBTemperature is
above this value, s100ThermoBOperationalStatus would be
'overUpper… | column | Integer32 | .1.3.6.1.4.1.5504.2.4.1.3.1.5 |
| sechtor100ThermoALowerThreshold This variable specifies the lower threshold for thermometer
A in degrees Celsius. When s100ThermoATemperature is
below this value, s100ThermoAOperationalStatus would be
'belowLowe… | column | Integer32 | .1.3.6.1.4.1.5504.2.4.1.3.1.6 |
| sechtor100ThermoBLowerThreshold This variable specifies the lower threshold for thermometer
B in degrees Celsius. When s100ThermoATemperature is
below this value, s100ThermoBOperationalStatus would be
'belowLowe… | column | Integer32 | .1.3.6.1.4.1.5504.2.4.1.3.1.7 |
| sechtor100ThermoATemperature The temperature in degrees Celsius read by the IC
thermometer sensor A on the PCB board. It is effectively
the internal ambient temperature inside the enclosure
where thermometer… | column | Integer32 | .1.3.6.1.4.1.5504.2.4.1.3.1.8 |
| sechtor100ThermoBTemperature The temperature in degrees Celsius read by the IC
thermometer sensor B on the PCB board. It is effectively
the internal ambient temperature inside the enclosure
where thermometer… | column | Integer32 | .1.3.6.1.4.1.5504.2.4.1.3.1.9 |