sechtor100RedundancyEnable
ZHONE-SECHTOR100-MIB ·
.1.3.6.1.4.1.5504.2.4.1.3.1.2
Object
Whether or not the redundancy functionality has been enabled. If this value is false, redundancy is not enable.
Context
- MIB
- ZHONE-SECHTOR100-MIB
- OID
.1.3.6.1.4.1.5504.2.4.1.3.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- sechtor100ConfigEntry
- Table
- sechtor100ConfigTable
- Siblings
- 11
Values & Constraints
Type Values
1 | true |
2 | false |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| sechtor100PeerMacAddress This is the Mac address of the peer s100 unit. | column | SNMPv2-TCMacAddress | .1.3.6.1.4.1.5504.2.4.1.3.1.1 |
| sechtor100ThermoAOperationalStatus The operational status indicator for thermometer A.
Valid values are:
* withinOperationalRange - s100ThermoATemperature is within
its lower and upper threshold ra… | column | Enumeration | .1.3.6.1.4.1.5504.2.4.1.3.1.10 |
| sechtor100ThermoBOperationalStatus The operational status indicator for thermometer B.
Valid values are:
* withinOperationalRange - s100ThermoBTemperature is within
its lower and upper threshold ra… | column | Enumeration | .1.3.6.1.4.1.5504.2.4.1.3.1.11 |
| sechtor100RowStatus Used to control row creation and deletion.
A row in this table is created using a single
SNMP SET request with varbinds for:
a) sechtor100RowStatus set to'CreateA… | column | Zhone-TCZhoneRowStatus | .1.3.6.1.4.1.5504.2.4.1.3.1.12 |
| sechtor100FanOperationalStatus This variable describes the working status of the four fans
for the Sechtor 100. If any one of the four fans is not
running correctly, this variable shows 'fanFailure'. When
all t… | column | Enumeration | .1.3.6.1.4.1.5504.2.4.1.3.1.3 |
| sechtor100ThermoAUpperThreshold This variable specifies the upper threshold for thermometer
A in degrees Celsius. When s100ThermoATemperature is
above this value, s100ThermoAOperationalStatus would be
'overUpper… | column | Integer32 | .1.3.6.1.4.1.5504.2.4.1.3.1.4 |
| sechtor100ThermoBUpperThreshold This variable specifies the upper threshold for thermometer
B in degrees Celsius. When s100ThermoBTemperature is
above this value, s100ThermoBOperationalStatus would be
'overUpper… | column | Integer32 | .1.3.6.1.4.1.5504.2.4.1.3.1.5 |
| sechtor100ThermoALowerThreshold This variable specifies the lower threshold for thermometer
A in degrees Celsius. When s100ThermoATemperature is
below this value, s100ThermoAOperationalStatus would be
'belowLowe… | column | Integer32 | .1.3.6.1.4.1.5504.2.4.1.3.1.6 |
| sechtor100ThermoBLowerThreshold This variable specifies the lower threshold for thermometer
B in degrees Celsius. When s100ThermoATemperature is
below this value, s100ThermoBOperationalStatus would be
'belowLowe… | column | Integer32 | .1.3.6.1.4.1.5504.2.4.1.3.1.7 |
| sechtor100ThermoATemperature The temperature in degrees Celsius read by the IC
thermometer sensor A on the PCB board. It is effectively
the internal ambient temperature inside the enclosure
where thermometer… | column | Integer32 | .1.3.6.1.4.1.5504.2.4.1.3.1.8 |
| sechtor100ThermoBTemperature The temperature in degrees Celsius read by the IC
thermometer sensor B on the PCB board. It is effectively
the internal ambient temperature inside the enclosure
where thermometer… | column | Integer32 | .1.3.6.1.4.1.5504.2.4.1.3.1.9 |