wtnMinorAlarmStatus

ZHONE-PHY-WTN-RADIO-MIB · .1.3.6.1.4.1.5504.5.8.2.1.3

Object

column Bits
Current radio alarm status details.  
              
BIT     Hex     Decimal BIT NAME
Number  Value   Value	
------  ------  ------- ----------------------
0       0x01    1       RSSI_DEVIATION
1       0x02    2       IDU_OOL
2       0x04    4       ODU_TEMP_ALERT
3       0x08    8       RX_BER_ALARM
4       0x10    16      RX_EBNO_ALARM
5       0x20    32      (reserved)
6       0x40    64      (reserved)
7       0x80    128     (reserved)
8       0x100   256     IDU_EQUIP_FAIL
9       0x200   512     ODU_EQUIP_FAIL
10      0x400   1024    IDU_ODU_LINK_FAIL
11      0x800   2048    MC_CHANNEL_FAIL
12      0x1000  4096    (reserved)
13      0x2000  8192    (reserved)
14      0x4000  16384   (reserved)
15      0x8000  32768   SERVICE_AFFECTED
              
IDU_EQUIP_FAIL - can be caused by:
power supply failure, watchdog timeout, or other internal
failure on indoor unit.
              
IDU_ODU_LINK_FAIL - can be caused by:
IDU/ODU cable failure, bad connection, or equipment failure
              
IDU_OOL - can be caused by:
intermittent loss of lock of internal clocks
              
MC_CHANNEL_FAIL - can be caused by:
Signal path (air) degradation, or internal equipment failure 
on near end or far end node.
              
ODU_EQUIP_FAIL - can be caused by:
Loss of frequency lock, loss of clock reference, power fault, 
excessive transmitter power, signal path degradation, 
frequency drift, or internal failure of equipment in outdoor
unit.
              
ODU_TEMP_ALERT - can be caused by:
Operating temperature too high or too low.   Allowable range
of operating temperatures ( in ODU ) are -40C to +65C.
              
RSSI_DEVIATION - can be caused by:
signal path (air) degradation, excessive heat buildup at ODU,
or frequency drift.
              
RX_BER_ALARM - can be caused by:
RF noise burst, fade burst, interference, or internal equipment 
failure.
              
RX_EBNO_ALARM - can be caused by:
Fade, noise burst, or internal equipment stress.
              
              
The SERVICE_AFFECTING bit should always = 0 on this variable
because, by definition, minor alarms may not affect service.

Context

MIB
ZHONE-PHY-WTN-RADIO-MIB
OID
.1.3.6.1.4.1.5504.5.8.2.1.3
Type
column
Access
readonly
Status
current
Parent
wtnStatusEntry
Table
wtnStatusTable
Siblings
5

Syntax

Bits

Values & Constraints

Enumerated Values
0rssiDeviation
1iduOOL
2oduTempAlert
3rxBerAlarm
4rxEbnoAlarm
5unused5
6unused6
7unused7
8iduEquipFail
9oduEquipFail
10iduOduLinkFail
11mcChannelFail
12unused12
13unused13
14unused14
15serviceAffected

Related Objects