wtnIduOduLinkFail
ZHONE-PHY-WTN-RADIO-MIB ·
.1.3.6.1.4.1.5504.5.8.5.0.4
Object
notification
Intermittent failure of IDU to ODU communications link trap. can be caused by: IDU/ODU cable failure, bad connection, or spurious equipment failure.
Context
- MIB
- ZHONE-PHY-WTN-RADIO-MIB
- OID
.1.3.6.1.4.1.5504.5.8.5.0.4- Type
- notification
- Status
- current
- Parent
- wtnTraps
- Siblings
- 14
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wtnIduEquipFailCritical Critical indoor equipment failure trap.
Can be caused by:
power supply failure, watchdog timeout, or other internal
failure on indoor unit. | notification | - | .1.3.6.1.4.1.5504.5.8.5.0.1 |
| wtnOduEquipFail Spurious or intermittant ODU hardware failure trap.
Could be loss of reference signal from IDU or hardware error. | notification | - | .1.3.6.1.4.1.5504.5.8.5.0.10 |
| wtnOduTempAlertCritical Significant deviation of ODU temperature from specified limits
May be power amp heating up or environment heat buildup, or
environment ice or frost. | notification | - | .1.3.6.1.4.1.5504.5.8.5.0.11 |
| wtnOduTempAlert Warning to indicate that ODU is approaching a significant
deviation of ODU temperature from specified limits.
May be power amp heating up or environment heat buildup, or
environ… | notification | - | .1.3.6.1.4.1.5504.5.8.5.0.12 |
| wtnRSSIDeviation Receive signal strength at the odu is lower (in dB) than wtnOduRxRSSIThresh.
This alarm will persist until the RSSI rises above wtnOduRxRSSIThresh - wtnOduRxRssiHysteresisWindow… | notification | - | .1.3.6.1.4.1.5504.5.8.5.0.13 |
| wtnBerAlarm Modem reports temporary BER > threshold alarm.
Condition is true when current BER > wtnMdmRxBERThresh.
Condition will persist until current BER < ( wtnMdmRxBERThresh - wtnMdmRxBE… | notification | - | .1.3.6.1.4.1.5504.5.8.5.0.14 |
| wtnEbNoAlarm Modem reports temporary post-detection signal to noise ratio
below preset threshold wtnMdmRxEbNoThresh.
This condition will persist until the radio signal quality
ri… | notification | - | .1.3.6.1.4.1.5504.5.8.5.0.15 |
| wtnIduEquipFail Non-critical indoor equipment failure trap.
Can be caused by:
spurious power supply failure,
or other temporary internal failure on indoor unit. | notification | - | .1.3.6.1.4.1.5504.5.8.5.0.2 |
| wtnIduOduLinkFailCritical Critical failure of IDU to ODU communications link trap.
can be caused by:
IDU/ODU cable failure,
bad connection, or
equipment failure. | notification | - | .1.3.6.1.4.1.5504.5.8.5.0.3 |
| wtnIduOutOfLockCritical Permanent or persistant loss of lock of internal clocks
in indoor unit. | notification | - | .1.3.6.1.4.1.5504.5.8.5.0.5 |
| wtnIduOutOfLock Spurious or intermittant loss of lock of internal
clocks in indoor unit. | notification | - | .1.3.6.1.4.1.5504.5.8.5.0.6 |
| wtnMcChannelFailCritical Radio overhead channel failure trap. May be caused by
signal path degradation, or equipment failure on local or
far end node. | notification | - | .1.3.6.1.4.1.5504.5.8.5.0.7 |
| wtnMcChannelFail Spurious or intermittant radio overhead channel failure trap.
May be caused by signal path degradation
or equipment failure on local or
far end node. | notification | - | .1.3.6.1.4.1.5504.5.8.5.0.8 |
| wtnOduEquipFailCritical Critical ODU hardware failure trap. Possible causes:
Synthesizer has lost desired frequency.
Could be loss of reference signal from IDU or hardware error.
Synthesizer hardware … | notification | - | .1.3.6.1.4.1.5504.5.8.5.0.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wtnTrapCondition Sent with wireless traps to indicate whether condition has
arrived or has gone away. | scalar | Enumeration | .1.3.6.1.4.1.5504.5.8.5.1 |
| wtnServiceAffected Flag sent with each trap to indicate whether service may be
affected by this particular trap condition.
Service affecting means that payload data (DS3, etc)
MAY be aff… | scalar | Enumeration | .1.3.6.1.4.1.5504.5.8.5.2 |