radioTotalSES
ZHONE-PHY-WTN-RADIO-MIB ·
.1.3.6.1.4.1.5504.5.8.6.1.2
Object
Count of the number of seconds the radio endured severe conditions
since system came up or value was reset.
A severe condition occurs if:
1 - received BER is greater exceeds the BER threshold and has not yet
dropped below the BER hysteresis window.
2- radio link failure. Radio signal cannot be detected.
Writing any value to this counter will reset the count.
Context
- MIB
- ZHONE-PHY-WTN-RADIO-MIB
- OID
.1.3.6.1.4.1.5504.5.8.6.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- radioTotalEntry
- Table
- radioTotalTable
- Siblings
- 2
Syntax
SNMPv2-SMIGauge32
- Source
- SNMPv2-SMIGauge32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| radioTotalES Number of seconds the radio link detected bit errors since
the system has been up, or since last reset.
If the BER is above the
user set threshhold then the rea… | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.5504.5.8.6.1.1 |
| radioTotalUAS Unavailable seconds. This value is incremented once per second after
ten consecutive radioCurrentSES (severe-error seconds) are counted.
An equipment failure will also incremen… | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.5504.5.8.6.1.3 |