zhoneAtmVclExtFaultDetectionType
ZHONE-COM-ATM-MIB ·
.1.3.6.1.4.1.5504.4.2.2.1.1.1
Object
column
r/w
Enumeration
This is used to configure VCL fault detection. The valid values
are:
* disabled - Fault detection is disabled. This is the default.
* oamF5Loopback - This option uses standard OAM fault
management cells as defined in ITU.610 for fault detection.
Automatic loopback diagnostic cells are sent to the IAD.
When fault detection is enabled, atmVclOperStatusChange
notification trap is used to indicate to the NMS station
an VCL has gone down or has come back up.
Context
- MIB
- ZHONE-COM-ATM-MIB
- OID
.1.3.6.1.4.1.5504.4.2.2.1.1.1- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- zhoneAtmVclExtEntry
- Table
- zhoneAtmVclExtTable
- Siblings
- 5
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | disabled |
2 | oamF5Loopback |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| zhoneAtmVclExtOamF5Ping This is used to send a OAM F5 loopback cell for fault detection.
The value will automatically revert to disabled after the set
is complete. The valid values are:
* … | column | Enumeration | .1.3.6.1.4.1.5504.4.2.2.1.1.2 |
| zhoneAtmVclExtOamF5PingStatus TRUE if ping was successfull and FALSE if failed | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.5504.4.2.2.1.1.3 |
| zhoneAtmVclExtTrafficContainerIndex Index number of a PON traffic container associated with a
VCL definition. | column | Integer32 | .1.3.6.1.4.1.5504.4.2.2.1.1.4 |
| zhoneAtmVclExtOamF4Ping This is used to send a OAM F4 loopback cell for fault detection.
The value will automatically revert to disabled after the set
is complete. The valid values are:
* … | column | Enumeration | .1.3.6.1.4.1.5504.4.2.2.1.1.5 |
| zhoneAtmVclExtOamF4PingStatus TRUE if ping was successfull and FALSE if failed. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.5504.4.2.2.1.1.6 |