xupstdAmbientTempBad
XUPS-MIB ·
.1.3.6.1.4.1.534.1.11.4.1.0.29
Object
notification
The ambient temperature, xupsEnvAmbientTemp, has fallen below the set lower limit, xupsEnvAmbientLowerLimit, or has risen above the set upper limit, xupsEnvAmbientUpperLimit.
Context
- MIB
- XUPS-MIB
- OID
.1.3.6.1.4.1.534.1.11.4.1.0.29- Type
- notification
- Status
- current
- Parent
- xupsTrapOidDefined
- Siblings
- 49
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| xupstdControlOff The UPS output power will turn off in a number of
seconds equal to upsControlOutputOffTrapDelay. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.1 |
| xupstdInverterFailure The ups inverter is unavailable or malfunctioning due to an internal failure. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.10 |
| xupstdTestTrap This trap is sent to the trap receivers to check proper reception of traps. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.100 |
| xupstdOnBypass The ups has gone on bypass for some reason. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.11 |
| xupstdBypassNotAvailable The ups bypass is unavailable | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.12 |
| xupstdOutputOff The ups output is switched off. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.13 |
| xupstdInputFailure The ups input power is incorrect in voltage,
frequency, or phase rotation. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.14 |
| xupstdBuildingAlarm One of the defined building alarms has occurred. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.15 |
| xupstdShutdownImminent The ups shutdown imminent alarm has occurred. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.16 |
| xupstdOnInverter The ups is returned to utility power running the inverter
after either a transfer to bypass or a run on battery. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.17 |
| xupstdControlOn The UPS output power will turn on in a number of
seconds equal to upsControlOutputOnTrapDelay. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.2 |
| xupstdBreakerOpen One of the UPS breakers or contactors has been opened. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.20 |
| xupstdAlarmEntryAdded An alarm not defined in the xups Well Known Alarms
(eg, an alarm defined in RFC1628)
has been added to the Alarm Table. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.21 |
| xupstdAlarmEntryRemoved An alarm not defined in the xups Well Known Alarms
has been removed from the Alarm Table. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.22 |
| xupstdAlarmBatteryBad One or more batteries have been determined to require replacement. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.23 |
| xupstdOutputOffAsRequested The UPS has shutdown as requested, i.e., the output is off. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.24 |
| xupstdDiagnosticTestFailed The result of the last diagnostic test indicates a failure. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.25 |
| xupstdCommunicationsLost A problem has been encountered in the communications
between the agent and the UPS. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.26 |
| xupstdUpsShutdownPending An xupsControlOutputOffDelay countdown is underway. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.27 |
| xupstdAlarmTestInProgress A test is in progress, as initiated and indicated by the xupsTest Group.
When the test is complete, one of the following traps will be sent:
- xupstdDiagnosticTestFailed if the … | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.28 |
| xupstdOnBattery The UPS has no AC input power and is running on
battery. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.3 |
| xupstdContactActiveNotice The Contact indicated by xupsContactIndex is in its Active state.
The following are the situations that generate this trap:
For xupsContactType: and xupsContactState:
… | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.30 |
| xupstdContactInactiveNotice The Contact indicated by xupsContactIndex has changed to its Inactive state. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.31 |
| xupstdLossOfRedundancy A parallel UPS system is no longer operating in N+1 redundant mode;
this may be due to module failure or removal, or due to overloading. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.32 |
| xupstdAlarmTempBad An internal temperature is out of tolerance. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.33 |
| xupstdAlarmChargerFailed An uncorrected problem has been detected within the UPS charger subsystem. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.34 |
| xupstdAlarmFanFailure The failure of one or more fans in the UPS has been detected. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.35 |
| xupstdAlarmFuseFailure The failure of one or more fuses has been detected. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.36 |
| xupstdPowerSwitchBad A Relay, Contactor, or Breaker has failed. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.37 |
| xupstdModuleFailure One module in a parallel or composite system has failed. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.38 |
| xupstdOnAlternatePowerSource The system is being powered by its Alternate Power Source, such as a
Secondary utility feed (on a dual AC input UPS), generator, flywheel,
or fuel cell. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.39 |
| xupstdLowBattery The UPS batteries are low. Tied to low battery
alarm condition. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.4 |
| xupstdAltPowerNotAvailable On systems with a separate alternate power source (eg, dual AC inputs),
that alternate power source is currently not available. This could be
a problem if the primary power sou… | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.40 |
| xupstdNoticeCondition Some Notice condition exists which is not covered by the other traps.
This is like an xupstdInternalFailure, but at a lower severity level. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.41 |
| xupstdRemoteTempBad The remote temperature, xupsEnvRemoteTemp, has fallen below
the set lower limit, xupsEnvRemoteTempLowerLimit, or has risen above
the set upper limit, xupsEnvRemoteTempUpperLimit. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.42 |
| xupstdRemoteHumidityBad The remote temperature, xupsEnvRemoteHumidity, has fallen below
the set lower limit, xupsEnvRemoteHumidityLowerLimit, or has risen above
the set upper limit, xupsEnvRemoteHumidi… | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.43 |
| xupstdHeartbeat A periodic status trap message. It is sent at an interval
set by object xupsHeartbeatMinsInterval.
The included variables provide a brief statement of the UPS status. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.44 |
| xupstdDiagnosticTestPassed A diagnostic test just completed, and its result is Passed.
The included variables provide additional information on the test. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.45 |
| xupstdOutputBad The output condition (other than OutputOverload) is out of tolerance. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.46 |
| xupstdAwaitingPower The UPS output is off and the UPS is awaiting the return of input power. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.47 |
| xupstdOnMaintenanceBypass The UPS has been placed on Maintenance / Manual Bypass by an operator. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.48 |
| xupstdCommEstablished This trap is sent when the SNMP agent first establishes a communication
link with the UPS.
The included variables provide identification and UPS status information. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.49 |
| xupstdUtilityPowerRestored Input power has been restored after running on battery. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.5 |
| xupstdAgentDown This trap is sent when the SNMP agent is exiting or closing down gracefully.
This may be triggered by a signal from the OS to stop this process. In many
implementations, it will … | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.50 |
| xupstdOutputNotProtected The ups output is not protectet for any reason in the UPS. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.51 |
| xupstdReturnFromLowBattery The battery has recovered from a low battery condition. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.6 |
| xupstdOutputOverload The ups has sensed an overload of greater than
106 percent. Tied to the 106% overload alarm. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.7 |
| xupstdInternalFailure Some component of the ups - rectifier, inverter,
control panel has failed. Tied to alarms indi-
cating failure. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.8 |
| xupstdBatteryDischarged The Battery Totally Discharged Alarm has occurred. | notification | - | .1.3.6.1.4.1.534.1.11.4.1.0.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| xupsAlarmID A unique identifier for an alarm condition. | column | Integer32 | .1.3.6.1.4.1.534.1.7.2.1.1 |
| xupsAlarmDescr A reference to an alarm description object. The object
referenced should not be accessible, but rather be used to
provide a unique description of the alarm condition. | column | ObjectIdentifier | .1.3.6.1.4.1.534.1.7.2.1.2 |
| xupsTrapMessage A descriptive text message which may be sent with traps to
further explain the reason for the trap.
This object is not-accessible to MIB browsers, but had to be changed to
read-on… | scalar | OctetString | .1.3.6.1.4.1.534.1.11.3 |
| xupsEnvAmbientTemp The reading of the ambient temperature in the vicinity of the
UPS or SNMP agent. | scalar | degrees Centigrade Integer32 | .1.3.6.1.4.1.534.1.6.1 |
| xupsEnvAmbientLowerLimit The Lower Limit of the ambient temperature; if xupsEnvAmbientTemp
falls below this value, the xupsAmbientTempBad alarm will occur. | scalar | degrees Centigrade Integer32 | .1.3.6.1.4.1.534.1.6.2 |
| xupsEnvAmbientUpperLimit The Upper Limit of the ambient temperature; if xupsEnvAmbientTemp
rises above this value, the xupsAmbientTempBad alarm will occur.
This value should be greater than xupsEnvAmbien… | scalar | degrees Centigrade Integer32 | .1.3.6.1.4.1.534.1.6.3 |