wtWebioEA2x2ERPSessCntrlPassword
Webio-Digital-MIB-US ·
.1.3.6.1.4.1.5040.1.2.25.2.1
Object
scalar
mandatory
r/w
OctetString
Entering this password opens a session which is ended by writing a 1 to wtWebioEA2x2ERPSessCntrlLogout. When read this variable provides a string of length zero.
Context
- MIB
- Webio-Digital-MIB-US
- OID
.1.3.6.1.4.1.5040.1.2.25.2.1- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- wtWebioEA2x2ERPSessCntrl
- Siblings
- 4
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wtWebioEA2x2ERPSessCntrlConfigMode mandatory When the device is in SNMP configuration mode, the value 1 is
returned, otherwise 0. If the read value is 0 even though the password
was written, the device is already in config m… | scalar | Integer32 | .1.3.6.1.4.1.5040.1.2.25.2.2 |
| wtWebioEA2x2ERPSessCntrlLogout mandatory If the device is in configuration mode and the session was opened by
this SNMP Manager, writing a 1 to this variable will end the session
and all parameters are stored.
Writing a… | scalar | Integer32 | .1.3.6.1.4.1.5040.1.2.25.2.3 |
| wtWebioEA2x2ERPSessCntrlAdminPassword mandatory This password protects access to the variables with administrator rights.
It can only be changed by the administrator. If no password was assigned,
the valid password is public. | scalar | OctetString | .1.3.6.1.4.1.5040.1.2.25.2.4 |
| wtWebioEA2x2ERPSessCntrlConfigPassword mandatory This password protects access to the variables with configurator rights. It can
be changed by the administrator and by the configurator. If no password was assigned,
the valid pa… | scalar | OctetString | .1.3.6.1.4.1.5040.1.2.25.2.5 |