wtWebioEA12x12HttpInputTrigger
Webio-Digital-MIB-US ·
.1.3.6.1.4.1.5040.1.2.4.3.1.3.2.3
Object
scalar
mandatory
r/w
OctetString
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input bits.
If a bit is set (1), a change of state on the corresponding input
triggers a transmission. If the bit is not set (0), no transmission
takes place.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3, Bit 0-3: Digital inputs 8-11
Bit 4-7: unused
OCTET 4, Bit 0-7: Digital inputs 0-7
Context
- MIB
- Webio-Digital-MIB-US
- OID
.1.3.6.1.4.1.5040.1.2.4.3.1.3.2.3- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- wtWebioEA12x12HTTP
- Siblings
- 3
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wtWebioEA12x12Startup mandatory Binary coded start page, more than one page must not be selected:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 2: user.htm
Bit 1: home.htm
Bit 0: index.… | scalar | OctetString | .1.3.6.1.4.1.5040.1.2.4.3.1.3.2.1 |
| wtWebioEA12x12GetHeaderEnable mandatory If bits are set, every answer of a short form GET question will be lead
by the IP-address and name of the device (Header) or a HTTP header (HTTP):
Octet 1: unused
Octet 2: unused
… | scalar | OctetString | .1.3.6.1.4.1.5040.1.2.4.3.1.3.2.2 |
| wtWebioEA12x12HttpPort mandatory Definition of the standard HTML port (Default: 80). | scalar | Integer32 | .1.3.6.1.4.1.5040.1.2.4.3.1.3.2.4 |