wwpLeosNtpClientPollFreq

WWP-LEOS-NTP-CLIENT-MIB · .1.3.6.1.4.1.6141.2.60.18.1.1.3

Object

scalar r/w Integer32
The polling frequency at which NTP server will be polled
if the NTP client is configured to be in polling mode.
The value of this object should be multiple of 16.
The change in the NTP mode will only be effective 
when NTP client is enabled and should not be set at
the same time either Min or Max polling frequency is set.

Context

MIB
WWP-LEOS-NTP-CLIENT-MIB
OID
.1.3.6.1.4.1.6141.2.60.18.1.1.3
Type
scalar
Access
readwrite
Status
current
Parent
wwpLeosNtpClient
Siblings
17

Syntax

Integer32

Values & Constraints

Object Constraints
range: 16-4096