vmwNsxTTransportNodeHealthTransportNodeUplinkDownOnDPU

VMWARE-NSX-MIB · .1.3.6.1.4.1.6876.120.1.0.18.0.11

Object

notification
Uplink on DPU vmwNsxTDataCenterDPUId is going down.
          
Action required:
Check the physical NICs' status of uplinks on DPU vmwNsxTDataCenterDPUId.
Find out the mapped name of this physical NIC on host, then perform checking on UI.
1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes |
Host Transport Nodes.
2. In the Host Transport Nodes list, check the Node Status column. Find the
Transport node with the degraded or down Node Status.
3. Select <transport node> | Monitor. Check the status details of the
bond(uplink) which is reporting degraded or down. To avoid a degraded state,
ensure all uplink interfaces are connected and up regardless of whether they
are in use or not.