vmwNsxTTransportNodeHealthTransportNodeUplinkDownOnDPU
VMWARE-NSX-MIB ·
.1.3.6.1.4.1.6876.120.1.0.18.0.11
Object
notification
Uplink on DPU vmwNsxTDataCenterDPUId is going down.
Action required:
Check the physical NICs' status of uplinks on DPU vmwNsxTDataCenterDPUId.
Find out the mapped name of this physical NIC on host, then perform checking on UI.
1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes |
Host Transport Nodes.
2. In the Host Transport Nodes list, check the Node Status column. Find the
Transport node with the degraded or down Node Status.
3. Select <transport node> | Monitor. Check the status details of the
bond(uplink) which is reporting degraded or down. To avoid a degraded state,
ensure all uplink interfaces are connected and up regardless of whether they
are in use or not.
Context
- MIB
- VMWARE-NSX-MIB
- OID
.1.3.6.1.4.1.6876.120.1.0.18.0.11- Type
- notification
- Status
- current
- Parent
- vmwNsxTTransportNodeHealthFeature
- Siblings
- 9
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTTransportNodeHealthLAGMemberDownOnDPUClear LACP on DPU vmwNsxTDataCenterDPUId reporting member up.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.18.0.10 |
| vmwNsxTTransportNodeHealthTransportNodeUplinkDownOnDPUClear Uplink on DPU vmwNsxTDataCenterDPUId is going up.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.18.0.12 |
| vmwNsxTTransportNodeHealthNVDSUplinkDown Uplink is going down.
Action required:
Check the physical NICs' status of uplinks on hosts.
1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes |
Host Transpo… | notification | - | .1.3.6.1.4.1.6876.120.1.0.18.0.3 |
| vmwNsxTTransportNodeHealthNVDSUplinkDownClear Uplink is going up.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.18.0.4 |
| vmwNsxTTransportNodeHealthLAGMemberDown LACP reporting member down.
Action required:
Check the connection status of LAG members on hosts.
1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes |
Host T… | notification | - | .1.3.6.1.4.1.6876.120.1.0.18.0.5 |
| vmwNsxTTransportNodeHealthLAGMemberDownClear LACP reporting member up.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.18.0.6 |
| vmwNsxTTransportNodeHealthTransportNodeUplinkDown Uplink is going down.
Action required:
Check the physical NICs' status of uplinks on hosts.
1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes |
Host Transpo… | notification | - | .1.3.6.1.4.1.6876.120.1.0.18.0.7 |
| vmwNsxTTransportNodeHealthTransportNodeUplinkDownClear Uplink is going up.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.18.0.8 |
| vmwNsxTTransportNodeHealthLAGMemberDownOnDPU LACP on DPU vmwNsxTDataCenterDPUId reporting member down.
Action required:
Check the connection status of LAG members on DPU vmwNsxTDataCenterDPUId.
Find out the mapped… | notification | - | .1.3.6.1.4.1.6876.120.1.0.18.0.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTDataCenterTimestamp The timestamp when the NSX Data Center event occurred. | scalar | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.6876.120.1.1.1 |
| vmwNsxTDataCenterFeatureName The NSX Data Center feature ID associated with the event. | scalar | VmwNsxTDataCenterFeatureIdType | .1.3.6.1.4.1.6876.120.1.1.2 |
| vmwNsxTDataCenterEventType The name of the NSX Data Center event. | scalar | VmwNsxTDataCenterEventTypeType | .1.3.6.1.4.1.6876.120.1.1.3 |
| vmwNsxTDataCenterEventSeverity The severity of the NSX Data Center event. | scalar | VmwNsxTDataCenterSeverityType | .1.3.6.1.4.1.6876.120.1.1.4 |
| vmwNsxTDataCenterNodeId The node ID from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeIdType | .1.3.6.1.4.1.6876.120.1.1.5 |
| vmwNsxTDataCenterNodeType The type of node from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeTypeType | .1.3.6.1.4.1.6876.120.1.1.6 |
| vmwNsxTDataCenterEntityId The ID of a NSX Data Center entity an event pertains to. The event
description field provides additional details of the entity. For
example the ID can be for a specific Load Balan… | scalar | VmwNsxTDataCenterEntityIdType | .1.3.6.1.4.1.6876.120.1.1.21 |
| vmwNsxTDataCenterDPUId This value is not expected to be empty. | scalar | VmwNsxTDataCenterDPUIdType | .1.3.6.1.4.1.6876.120.1.1.171 |