vmwNsxTTransportNodeHealthNVDSUplinkDown

VMWARE-NSX-MIB · .1.3.6.1.4.1.6876.120.1.0.18.0.3

Object

notification
Uplink is going down.
          
Action required:
Check the physical NICs' status of uplinks on hosts.
1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes |
Host Transport Nodes.
2. In the Host Transport Nodes list, check the Node Status column. Find the
Transport node with the degraded or down Node Status.
3. Select <transport node> | Monitor. Check the status details of the
bond(uplink) which is reporting degraded or down. To avoid a degraded state,
ensure all uplink interfaces are connected and up regardless of whether they
are in use or not.

Context

MIB
VMWARE-NSX-MIB
OID
.1.3.6.1.4.1.6876.120.1.0.18.0.3
Type
notification
Status
current
Parent
vmwNsxTTransportNodeHealthFeature
Siblings
9

Syntax

No syntax metadata recorded.

Values & Constraints

No enumerated values or constraints recorded.

Related Objects

Sibling Objects
Notification Objects