vmwNsxTTransportNodeHealthNVDSUplinkDown
VMWARE-NSX-MIB ·
.1.3.6.1.4.1.6876.120.1.0.18.0.3
Object
notification
Uplink is going down.
Action required:
Check the physical NICs' status of uplinks on hosts.
1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes |
Host Transport Nodes.
2. In the Host Transport Nodes list, check the Node Status column. Find the
Transport node with the degraded or down Node Status.
3. Select <transport node> | Monitor. Check the status details of the
bond(uplink) which is reporting degraded or down. To avoid a degraded state,
ensure all uplink interfaces are connected and up regardless of whether they
are in use or not.
Context
- MIB
- VMWARE-NSX-MIB
- OID
.1.3.6.1.4.1.6876.120.1.0.18.0.3- Type
- notification
- Status
- current
- Parent
- vmwNsxTTransportNodeHealthFeature
- Siblings
- 9
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTTransportNodeHealthLAGMemberDownOnDPUClear LACP on DPU vmwNsxTDataCenterDPUId reporting member up.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.18.0.10 |
| vmwNsxTTransportNodeHealthTransportNodeUplinkDownOnDPU Uplink on DPU vmwNsxTDataCenterDPUId is going down.
Action required:
Check the physical NICs' status of uplinks on DPU vmwNsxTDataCenterDPUId.
Find out the mapped name … | notification | - | .1.3.6.1.4.1.6876.120.1.0.18.0.11 |
| vmwNsxTTransportNodeHealthTransportNodeUplinkDownOnDPUClear Uplink on DPU vmwNsxTDataCenterDPUId is going up.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.18.0.12 |
| vmwNsxTTransportNodeHealthNVDSUplinkDownClear Uplink is going up.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.18.0.4 |
| vmwNsxTTransportNodeHealthLAGMemberDown LACP reporting member down.
Action required:
Check the connection status of LAG members on hosts.
1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes |
Host T… | notification | - | .1.3.6.1.4.1.6876.120.1.0.18.0.5 |
| vmwNsxTTransportNodeHealthLAGMemberDownClear LACP reporting member up.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.18.0.6 |
| vmwNsxTTransportNodeHealthTransportNodeUplinkDown Uplink is going down.
Action required:
Check the physical NICs' status of uplinks on hosts.
1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes |
Host Transpo… | notification | - | .1.3.6.1.4.1.6876.120.1.0.18.0.7 |
| vmwNsxTTransportNodeHealthTransportNodeUplinkDownClear Uplink is going up.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.18.0.8 |
| vmwNsxTTransportNodeHealthLAGMemberDownOnDPU LACP on DPU vmwNsxTDataCenterDPUId reporting member down.
Action required:
Check the connection status of LAG members on DPU vmwNsxTDataCenterDPUId.
Find out the mapped… | notification | - | .1.3.6.1.4.1.6876.120.1.0.18.0.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTDataCenterTimestamp The timestamp when the NSX Data Center event occurred. | scalar | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.6876.120.1.1.1 |
| vmwNsxTDataCenterFeatureName The NSX Data Center feature ID associated with the event. | scalar | VmwNsxTDataCenterFeatureIdType | .1.3.6.1.4.1.6876.120.1.1.2 |
| vmwNsxTDataCenterEventType The name of the NSX Data Center event. | scalar | VmwNsxTDataCenterEventTypeType | .1.3.6.1.4.1.6876.120.1.1.3 |
| vmwNsxTDataCenterEventSeverity The severity of the NSX Data Center event. | scalar | VmwNsxTDataCenterSeverityType | .1.3.6.1.4.1.6876.120.1.1.4 |
| vmwNsxTDataCenterNodeId The node ID from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeIdType | .1.3.6.1.4.1.6876.120.1.1.5 |
| vmwNsxTDataCenterNodeType The type of node from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeTypeType | .1.3.6.1.4.1.6876.120.1.1.6 |
| vmwNsxTDataCenterEntityId The ID of a NSX Data Center entity an event pertains to. The event
description field provides additional details of the entity. For
example the ID can be for a specific Load Balan… | scalar | VmwNsxTDataCenterEntityIdType | .1.3.6.1.4.1.6876.120.1.1.21 |