vmwNsxTDistributedFirewallDFWSessionCountHigh
VMWARE-NSX-MIB ·
.1.3.6.1.4.1.6876.120.1.0.31.0.5
Object
notification
The DFW session count is high on Transport node vmwNsxTDataCenterEntityId, it has
reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Review the network traffic load level of the workloads on the host.
Consider re-balancing the workloads on this host to other hosts.
Context
- MIB
- VMWARE-NSX-MIB
- OID
.1.3.6.1.4.1.6876.120.1.0.31.0.5- Type
- notification
- Status
- current
- Parent
- vmwNsxTDistributedFirewallFeature
- Siblings
- 23
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTDistributedFirewallDFWCPUUsageVeryHigh The DFW CPU usage on Transport node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high
threshold value of vmwNsxTDataCe… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.1 |
| vmwNsxTDistributedFirewallDFWRulesLimitPervNICExceededClear The DFW rules limit for VIF vmwNsxTDataCenterEntityId on the destination host
vmwNsxTDataCenterTransportNodeName dropped below maximum limit.
Action required:
None, rec… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.10 |
| vmwNsxTDistributedFirewallDFWRulesLimitPerHostApproaching The DFW rules limit for host vmwNsxTDataCenterTransportNodeName is approaching
the maximum limit.
Action required:
Log in into the ESX host vmwNsxTDataCenterTransportNo… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.11 |
| vmwNsxTDistributedFirewallDFWRulesLimitPerHostApproachingClear The DFW rules limit for host vmwNsxTDataCenterTransportNodeName dropped below the
threshold.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.12 |
| vmwNsxTDistributedFirewallDFWRulesLimitPerHostExceeded The DFW rules limit for host vmwNsxTDataCenterTransportNodeName
is about to exceed the maximum limit.
Action required:
Log in into the ESX host vmwNsxTDataCenterTranspo… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.13 |
| vmwNsxTDistributedFirewallDFWRulesLimitPerHostExceededClear The DFW rules limit for host vmwNsxTDataCenterTransportNodeName dropped below maximum
limit.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.14 |
| vmwNsxTDistributedFirewallDFWRulesLimitPervNICApproaching The DFW rules limit for VIF vmwNsxTDataCenterEntityId on destination host
vmwNsxTDataCenterTransportNodeName is approaching the maximum limit.
Action required:
Log in i… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.15 |
| vmwNsxTDistributedFirewallDFWRulesLimitPervNICApproachingClear The DFW rules limit for VIF vmwNsxTDataCenterEntityId on the destination host
vmwNsxTDataCenterTransportNodeName dropped below the threshold.
Action required:
None, rec… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.16 |
| vmwNsxTDistributedFirewallDFWCPUUsageVeryHighOnDPU The DFW CPU usage on Transport node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% on DPU vmwNsxTDataCenterDPUId which is at or above the very high
th… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.17 |
| vmwNsxTDistributedFirewallDFWCPUUsageVeryHighOnDPUClear The DFW CPU usage on Transport node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% on DPU vmwNsxTDataCenterDPUId which is below the very high
threshol… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.18 |
| vmwNsxTDistributedFirewallDFWMemoryUsageVeryHighOnDPU The DFW Memory usage vmwNsxTDataCenterHeapType on Transport node
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% on DPU vmwNsxTDataCenterDPUId which
is… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.19 |
| vmwNsxTDistributedFirewallDFWCPUUsageVeryHighClear The DFW CPU usage on Transport node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% which is below the very high
threshold value of vmwNsxTDataCenterSy… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.2 |
| vmwNsxTDistributedFirewallDFWMemoryUsageVeryHighOnDPUClear The DFW Memory usage vmwNsxTDataCenterHeapType on Transport node
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% on DPU vmwNsxTDataCenterDPUId which
is… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.20 |
| vmwNsxTDistributedFirewallDFWFloodLimitWarning The DFW flood limit for DFW filter vmwNsxTDataCenterEntityId on host
vmwNsxTDataCenterTransportNodeName has reached warning level of 80% of the configured limit for protocol vmwNs… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.21 |
| vmwNsxTDistributedFirewallDFWFloodLimitWarningClear The warning flood limit condition for DFW filter vmwNsxTDataCenterEntityId on host
vmwNsxTDataCenterTransportNodeName for protocol vmwNsxTDataCenterProtocolName is cleared.
… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.22 |
| vmwNsxTDistributedFirewallDFWFloodLimitCritical The DFW flood limit for DFW filter vmwNsxTDataCenterEntityId on host
vmwNsxTDataCenterTransportNodeName has reached critical level of 98% of the configured limit for protocol vmwN… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.23 |
| vmwNsxTDistributedFirewallDFWFloodLimitCriticalClear The critical flood limit condition for DFW filter vmwNsxTDataCenterEntityId on host
vmwNsxTDataCenterTransportNodeName for protocol vmwNsxTDataCenterProtocolName is cleared.
… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.24 |
| vmwNsxTDistributedFirewallDFWMemoryUsageVeryHigh The DFW Memory usage vmwNsxTDataCenterHeapType on Transport node
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which
is at or above the very high thr… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.3 |
| vmwNsxTDistributedFirewallDFWMemoryUsageVeryHighClear The DFW Memory usage vmwNsxTDataCenterHeapType on Transport node
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which
is below the very high threshold… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.4 |
| vmwNsxTDistributedFirewallDFWSessionCountHighClear The DFW session count on Transport node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% which is below the the threshold value of
vmwNsxTDataCenterSyst… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.6 |
| vmwNsxTDistributedFirewallDFWVmotionFailure The DFW vMotion for DFW filter vmwNsxTDataCenterEntityId on destination host
vmwNsxTDataCenterTransportNodeName has failed and the port for the entity has been
disconnected.
… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.7 |
| vmwNsxTDistributedFirewallDFWVmotionFailureClear The DFW configuration for DFW filter vmwNsxTDataCenterEntityId on the destination host
vmwNsxTDataCenterTransportNodeName has succeeded and error caused by DFW vMotion failure
cle… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.8 |
| vmwNsxTDistributedFirewallDFWRulesLimitPervNICExceeded The DFW rules limit for VIF vmwNsxTDataCenterEntityId on destination host
vmwNsxTDataCenterTransportNodeName is about to exceed the maximum limit.
Action required:
Log … | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTDataCenterTimestamp The timestamp when the NSX Data Center event occurred. | scalar | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.6876.120.1.1.1 |
| vmwNsxTDataCenterFeatureName The NSX Data Center feature ID associated with the event. | scalar | VmwNsxTDataCenterFeatureIdType | .1.3.6.1.4.1.6876.120.1.1.2 |
| vmwNsxTDataCenterEventType The name of the NSX Data Center event. | scalar | VmwNsxTDataCenterEventTypeType | .1.3.6.1.4.1.6876.120.1.1.3 |
| vmwNsxTDataCenterEventSeverity The severity of the NSX Data Center event. | scalar | VmwNsxTDataCenterSeverityType | .1.3.6.1.4.1.6876.120.1.1.4 |
| vmwNsxTDataCenterNodeId The node ID from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeIdType | .1.3.6.1.4.1.6876.120.1.1.5 |
| vmwNsxTDataCenterNodeType The type of node from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeTypeType | .1.3.6.1.4.1.6876.120.1.1.6 |
| vmwNsxTDataCenterEntityId The ID of a NSX Data Center entity an event pertains to. The event
description field provides additional details of the entity. For
example the ID can be for a specific Load Balan… | scalar | VmwNsxTDataCenterEntityIdType | .1.3.6.1.4.1.6876.120.1.1.21 |
| vmwNsxTDataCenterSystemResourceUsage The CPU, memory, or disk usage percentage of an NSX appliance. The
value is an integer between 0 and 100. | scalar | VmwNsxTDataCenterSystemResourceUsageType | .1.3.6.1.4.1.6876.120.1.1.22 |
| vmwNsxTDataCenterSystemUsageThreshold The configured threshold value for the CPU, memory, or disk usage
percentage of an NSX appliance. The value is an integer between 0 and
100. | scalar | VmwNsxTDataCenterSystemUsageThresholdType | .1.3.6.1.4.1.6876.120.1.1.34 |