vmwNsxTDistributedFirewallDFWRulesLimitPerHostApproaching
VMWARE-NSX-MIB ·
.1.3.6.1.4.1.6876.120.1.0.31.0.11
Object
notification
The DFW rules limit for host vmwNsxTDataCenterTransportNodeName is approaching
the maximum limit.
Action required:
Log in into the ESX host vmwNsxTDataCenterTransportNodeName and invoke the NSX CLI
command `get firewall rule-stats total` to get the rule statistics
for rules configured on the ESX host vmwNsxTDataCenterTransportNodeName.
Reduce the number of rules configured for host vmwNsxTDataCenterTransportNodeName.
Check the number of rules configured for various VIFs by using NSX CLI
command `get firewall <VIF_UUID> ruleset rules`.
Reduce the number of rules configured for various VIFs.
Context
- MIB
- VMWARE-NSX-MIB
- OID
.1.3.6.1.4.1.6876.120.1.0.31.0.11- Type
- notification
- Status
- current
- Parent
- vmwNsxTDistributedFirewallFeature
- Siblings
- 23
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTDistributedFirewallDFWCPUUsageVeryHigh The DFW CPU usage on Transport node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high
threshold value of vmwNsxTDataCe… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.1 |
| vmwNsxTDistributedFirewallDFWRulesLimitPervNICExceededClear The DFW rules limit for VIF vmwNsxTDataCenterEntityId on the destination host
vmwNsxTDataCenterTransportNodeName dropped below maximum limit.
Action required:
None, rec… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.10 |
| vmwNsxTDistributedFirewallDFWRulesLimitPerHostApproachingClear The DFW rules limit for host vmwNsxTDataCenterTransportNodeName dropped below the
threshold.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.12 |
| vmwNsxTDistributedFirewallDFWRulesLimitPerHostExceeded The DFW rules limit for host vmwNsxTDataCenterTransportNodeName
is about to exceed the maximum limit.
Action required:
Log in into the ESX host vmwNsxTDataCenterTranspo… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.13 |
| vmwNsxTDistributedFirewallDFWRulesLimitPerHostExceededClear The DFW rules limit for host vmwNsxTDataCenterTransportNodeName dropped below maximum
limit.
Action required:
None, receipt of this notification indicates event cleared. | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.14 |
| vmwNsxTDistributedFirewallDFWRulesLimitPervNICApproaching The DFW rules limit for VIF vmwNsxTDataCenterEntityId on destination host
vmwNsxTDataCenterTransportNodeName is approaching the maximum limit.
Action required:
Log in i… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.15 |
| vmwNsxTDistributedFirewallDFWRulesLimitPervNICApproachingClear The DFW rules limit for VIF vmwNsxTDataCenterEntityId on the destination host
vmwNsxTDataCenterTransportNodeName dropped below the threshold.
Action required:
None, rec… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.16 |
| vmwNsxTDistributedFirewallDFWCPUUsageVeryHighOnDPU The DFW CPU usage on Transport node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% on DPU vmwNsxTDataCenterDPUId which is at or above the very high
th… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.17 |
| vmwNsxTDistributedFirewallDFWCPUUsageVeryHighOnDPUClear The DFW CPU usage on Transport node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% on DPU vmwNsxTDataCenterDPUId which is below the very high
threshol… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.18 |
| vmwNsxTDistributedFirewallDFWMemoryUsageVeryHighOnDPU The DFW Memory usage vmwNsxTDataCenterHeapType on Transport node
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% on DPU vmwNsxTDataCenterDPUId which
is… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.19 |
| vmwNsxTDistributedFirewallDFWCPUUsageVeryHighClear The DFW CPU usage on Transport node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% which is below the very high
threshold value of vmwNsxTDataCenterSy… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.2 |
| vmwNsxTDistributedFirewallDFWMemoryUsageVeryHighOnDPUClear The DFW Memory usage vmwNsxTDataCenterHeapType on Transport node
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% on DPU vmwNsxTDataCenterDPUId which
is… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.20 |
| vmwNsxTDistributedFirewallDFWFloodLimitWarning The DFW flood limit for DFW filter vmwNsxTDataCenterEntityId on host
vmwNsxTDataCenterTransportNodeName has reached warning level of 80% of the configured limit for protocol vmwNs… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.21 |
| vmwNsxTDistributedFirewallDFWFloodLimitWarningClear The warning flood limit condition for DFW filter vmwNsxTDataCenterEntityId on host
vmwNsxTDataCenterTransportNodeName for protocol vmwNsxTDataCenterProtocolName is cleared.
… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.22 |
| vmwNsxTDistributedFirewallDFWFloodLimitCritical The DFW flood limit for DFW filter vmwNsxTDataCenterEntityId on host
vmwNsxTDataCenterTransportNodeName has reached critical level of 98% of the configured limit for protocol vmwN… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.23 |
| vmwNsxTDistributedFirewallDFWFloodLimitCriticalClear The critical flood limit condition for DFW filter vmwNsxTDataCenterEntityId on host
vmwNsxTDataCenterTransportNodeName for protocol vmwNsxTDataCenterProtocolName is cleared.
… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.24 |
| vmwNsxTDistributedFirewallDFWMemoryUsageVeryHigh The DFW Memory usage vmwNsxTDataCenterHeapType on Transport node
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which
is at or above the very high thr… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.3 |
| vmwNsxTDistributedFirewallDFWMemoryUsageVeryHighClear The DFW Memory usage vmwNsxTDataCenterHeapType on Transport node
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which
is below the very high threshold… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.4 |
| vmwNsxTDistributedFirewallDFWSessionCountHigh The DFW session count is high on Transport node vmwNsxTDataCenterEntityId, it has
reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the threshold
value of vmwNsxT… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.5 |
| vmwNsxTDistributedFirewallDFWSessionCountHighClear The DFW session count on Transport node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% which is below the the threshold value of
vmwNsxTDataCenterSyst… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.6 |
| vmwNsxTDistributedFirewallDFWVmotionFailure The DFW vMotion for DFW filter vmwNsxTDataCenterEntityId on destination host
vmwNsxTDataCenterTransportNodeName has failed and the port for the entity has been
disconnected.
… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.7 |
| vmwNsxTDistributedFirewallDFWVmotionFailureClear The DFW configuration for DFW filter vmwNsxTDataCenterEntityId on the destination host
vmwNsxTDataCenterTransportNodeName has succeeded and error caused by DFW vMotion failure
cle… | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.8 |
| vmwNsxTDistributedFirewallDFWRulesLimitPervNICExceeded The DFW rules limit for VIF vmwNsxTDataCenterEntityId on destination host
vmwNsxTDataCenterTransportNodeName is about to exceed the maximum limit.
Action required:
Log … | notification | - | .1.3.6.1.4.1.6876.120.1.0.31.0.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vmwNsxTDataCenterTimestamp The timestamp when the NSX Data Center event occurred. | scalar | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.6876.120.1.1.1 |
| vmwNsxTDataCenterFeatureName The NSX Data Center feature ID associated with the event. | scalar | VmwNsxTDataCenterFeatureIdType | .1.3.6.1.4.1.6876.120.1.1.2 |
| vmwNsxTDataCenterEventType The name of the NSX Data Center event. | scalar | VmwNsxTDataCenterEventTypeType | .1.3.6.1.4.1.6876.120.1.1.3 |
| vmwNsxTDataCenterEventSeverity The severity of the NSX Data Center event. | scalar | VmwNsxTDataCenterSeverityType | .1.3.6.1.4.1.6876.120.1.1.4 |
| vmwNsxTDataCenterNodeId The node ID from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeIdType | .1.3.6.1.4.1.6876.120.1.1.5 |
| vmwNsxTDataCenterNodeType The type of node from where a NSX Data Center event was emitted. | scalar | VmwNsxTDataCenterNodeTypeType | .1.3.6.1.4.1.6876.120.1.1.6 |
| vmwNsxTDataCenterEntityId The ID of a NSX Data Center entity an event pertains to. The event
description field provides additional details of the entity. For
example the ID can be for a specific Load Balan… | scalar | VmwNsxTDataCenterEntityIdType | .1.3.6.1.4.1.6876.120.1.1.21 |
| vmwNsxTDataCenterTransportNodeName This value is not expected to be empty. | scalar | VmwNsxTDataCenterTransportNodeNameType | .1.3.6.1.4.1.6876.120.1.1.46 |