utAlarmSeverity
UTS-FAULT-MIB ·
.1.3.6.1.4.1.1949.2.3.2.2.2.1.3
Object
scalar
AlarmSeverity
The severity of the alarm, that aligned with the ISO Ref.X.733: Cleared, Information, Critical, Major, Minor, and Warning.
Context
- MIB
- UTS-FAULT-MIB
- OID
.1.3.6.1.4.1.1949.2.3.2.2.2.1.3- Type
- scalar
- Access
- notifyonly
- Status
- current
- Parent
- utAlarmTrapMandatoryAttr
- Siblings
- 6
Syntax
AlarmSeverity
- Source
- AlarmSeverity
- Base type
Enumeration
Values & Constraints
Type Values
0 | alarmLevelClear |
1 | alarmLevelWarning |
2 | alarmLevelMinor |
3 | alarmLevelMajor |
4 | alarmLevelCritical |
5 | alarmLevelIndeterminate |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| utAlarmSeqNo Reserved for OAM. Application doesn't care this node at all. | scalar | SNMPv2-SMICounter32 | .1.3.6.1.4.1.1949.2.3.2.2.2.1.1 |
| utAlarmOccurrenceTime The occurrence time of alarm, which gives the time when the alarm is generated. | scalar | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.1949.2.3.2.2.2.1.2 |
| utAlarmProbableCause The probable cause of the alarm as defined in ISO Ref.X.733 and others. | scalar | ProbableCause | .1.3.6.1.4.1.1949.2.3.2.2.2.1.4 |
| utAlarmType The alarm type (categories, or classes) as defined in ISO Ref.X.733: Communication alarms, Qos alarms, Processing error alarms, Equipment alarms, and Environmental alarms. | scalar | AlarmType | .1.3.6.1.4.1.1949.2.3.2.2.2.1.5 |
| utAlarmClearType The item which indicates how the alarm can be cleared:
alarmClearAuto - the alarm is cleared by application itself
alarmClearManual - the alarm to be cleared by manual operati… | scalar | Enumeration | .1.3.6.1.4.1.1949.2.3.2.2.2.1.6 |
| utAlarmResourceType | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1949.2.3.2.2.2.1.7 |