freeNodeDiskSpaceLow
ThreeParMIB ·
.1.3.6.1.4.1.12925.1.2.0.201
Object
notification
Node <nid> free disk space is below acceptable limits: root <free_space>MB altroot <alt_space>MB common <comm_space>MB.
Context
- MIB
- ThreeParMIB
- OID
.1.3.6.1.4.1.12925.1.2.0.201- Type
- notification
- Status
- current
- Parent
- storeServAlerts
- Siblings
- 225
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| activeVlunLimitExceeded There are currently <num_luns> active VLUNs, which is above the supported limit of <max_luns> active VLUNs | notification | - | .1.3.6.1.4.1.12925.1.2.0.1 |
| metadataInconsistencyInADeduplicationGroup <cpg_name> <cpg_id> Deduplication Group not started due to metadata inconsistency; manual check required. | notification | - | .1.3.6.1.4.1.12925.1.2.0.10 |
| componentStateChangeDisabledBPort Disabled B Port; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.100 |
| componentStateChangeMissingBPort Missing B Port; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.101 |
| componentStateChangeErrorsOnBPort Errors on B Port; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.102 |
| componentStateChangeProlongedMissingBPort Prolonged Missing B Port; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.103 |
| componentStateChangeOverTemperatureWarning Over Temperature Warning; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.104 |
| componentStateChangeOverTemperatureAlert Over Temperature Alert; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.105 |
| componentStateChangeInvalidMedia Invalid Media; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.106 |
| componentStateChangeFailedHardware0x01f00deX153 Failed Hardware; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.107 |
| componentStateChangeSmartThresholdExceeded Smart Threshold Exceeded; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.108 |
| componentStateChangeMultipleChunkletsMediaBad Multiple Chunklets Media Bad; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.109 |
| vvUnrecoveredDifError Data Integrity Field (DIF) detected inconsistency for [[vvol]] | notification | - | .1.3.6.1.4.1.12925.1.2.0.11 |
| componentStateChangeMediaFailed0x01f00deX156 Media Failed; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.110 |
| componentStateChangeIncreasedErrorCount Increased Error Count; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.111 |
| componentStateChangeDifThresholdExceeded DIF Threshold Exceeded; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.112 |
| componentStateChangeProlongedNotReady Prolonged Not Ready; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.113 |
| componentStateChangeNoValidPorts No Valid Ports; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.114 |
| componentStateChangeInquiryFailed Inquiry Failed; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.115 |
| componentStateChangeUnitReadyFailed Unit Ready Failed; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.116 |
| componentStateChangeReadCapacityFailed Read Capacity Failed; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.117 |
| componentStateChangeWriteLabelFailed Write Label Failed; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.118 |
| componentStateChangeModePageUpdateFailed Mode Page Update Failed; Magazine <mag_id> Physical Disk <pd_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.119 |
| componentStateChangeMaintenanceCheckRequired Maintenance Check Required; Virtual Volume <vv_id>(<vv_name>) Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.12 |
| componentStateChangeReadLabelFailed Read Label Failed; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.120 |
| componentStateChangeMediumFormatCorrupted Medium Format Corrupted; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.121 |
| componentStateChangeLowWearLevelRemaining Low Wear Level Remaining; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.122 |
| componentStateChangeMiscompare Miscompare; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.123 |
| componentStateChangeInvalidCage Invalid Cage; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.124 |
| componentStateChangeSlowDrive Slow Drive; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.125 |
| componentStateChangeServicing Servicing; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.126 |
| componentStateChangeDriveErrorBitSet Drive Error Bit Set; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.127 |
| componentStateChangeFailedHardware0x01f00faX153 Failed Hardware; Disk <wwn_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.128 |
| componentStateChangeMediaFailed0x01f00faX156 Media Failed; Disk <wwn_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.129 |
| componentStateChangeLdsNotStarted LDs Not Started; Virtual Volume <vv_id>(<vv_name>) Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.13 |
| componentStateChangeReplaceDrive0x01f00faX70 Replace Drive; Disk <wwn_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.130 |
| internalErrorInAuthenticationLibrary Authentication internal error. Client address <IPaddr> port <port> | notification | - | .1.3.6.1.4.1.12925.1.2.0.131 |
| assertBatteryFail Node <node_id> PS <power_supply_id> Battery <battery_id>: Battery Failed during battery test. | notification | - | .1.3.6.1.4.1.12925.1.2.0.132 |
| componentStateChangeExpired Expired; Node <node_id> [Power Supply <power_supply_id>] Battery <battery_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.133 |
| componentStateChangeChargingFailed Charging Failed; Node <node_id> [Power Supply <power_supply_id>] Battery <battery_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.134 |
| componentStateChangeInternalError Internal Error; Node <node_id> [Power Supply <power_supply_id>] Battery <battery_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.135 |
| componentStateChangeLoadSharingFailed Load Sharing Failed; Node <node_id> [Power Supply <power_supply_id>] Battery <battery_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.136 |
| componentStateChangeFanFailed0x02200deX6 Fan Failed; Node <node_id> [Power Supply <power_supply_id>] Battery <battery_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.137 |
| componentStateChangeDcFailed0x02200deX7 DC Failed; Node <node_id> [Power Supply <power_supply_id>] Battery <battery_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.138 |
| componentStateChangeChargerFailed Charger Failed; Node <node_id> [Power Supply <power_supply_id>] Battery <battery_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.139 |
| componentStateChangeCopyFailed Copy Failed; Virtual Volume <vv_id>(<vv_name>) Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.14 |
| componentStateChangeFailed Failed; Node <node_id> [Power Supply <power_supply_id>] Battery <battery_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.140 |
| portShutdownOnFatalError Port <port_id> shut down: <time_shutdown> | notification | - | .1.3.6.1.4.1.12925.1.2.0.141 |
| hostPortIsDown Host port (<node>:<slot>:<port>) is down (<reason>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.142 |
| remoteCopyLinkStatus The Remote Copy link <remote_copy_link_process_name> has changed its status to <status> | notification | - | .1.3.6.1.4.1.12925.1.2.0.143 |
| replicationResourceUsageExceededGroupLogging Remote copy group <rm_grp_name> with ID <rm_grp_id> has transitioned to logging mode due to resource limitations. | notification | - | .1.3.6.1.4.1.12925.1.2.0.144 |
| replicationResourceUsageExceededGroupStopped Remote copy group <rm_grp_name> with ID <rm_grp_id> has been stopped due to resource limitations. | notification | - | .1.3.6.1.4.1.12925.1.2.0.145 |
| replicationResourcesRestoredGroupTransitionFromLoggingFailur Remote copy group <rm_grp_name> with ID <rm_grp_id> could not transition out of logging state when replication
resources became available, retrying. | notification | - | .1.3.6.1.4.1.12925.1.2.0.146 |
| noAdminNetworkInterfaceDiscovered The administrative network interface has failed on node [[hw_node]]. The system cannot be managed from this node. | notification | - | .1.3.6.1.4.1.12925.1.2.0.147 |
| tpVvAllocationSizeLimit Thin provisioned VV <name> has reached reserved allocation <limit> of <XX>G (<yy>% of <ZZ>G) | notification | - | .1.3.6.1.4.1.12925.1.2.0.148 |
| snapshotSpaceAllocationSizeLimit Reserved snapshot space for VV <name> has reached allocation <limit> of <XX>G (<yy>% of <ZZ>G) | notification | - | .1.3.6.1.4.1.12925.1.2.0.149 |
| componentStateChangeSnapdataInvalid Snapdata Invalid; Virtual Volume <vv_id>(<vv_name>) Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.15 |
| cpgGrowthLimit CPG <cpg name> SA space has reached allocation <limit> of <XX>G. | notification | - | .1.3.6.1.4.1.12925.1.2.0.150 |
| tpVvAllocationFailure Thin provisioned VV <name> <unable to> allocate <SA or SD or SD_2> space from CPG <cpg name> | notification | - | .1.3.6.1.4.1.12925.1.2.0.151 |
| snapshotSpaceAllocationFailure Snapshot space for VV <VV name> <unable to> allocate <SA or SD or SD_2> space from CPG <cpg name> | notification | - | .1.3.6.1.4.1.12925.1.2.0.152 |
| fcRawSpaceAllocation75Alert Total <FC> raw space usage at <ZZ> (above <75>% of total <total>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.153 |
| fcRawSpaceAllocation85Alert Total <FC> raw space usage at <ZZ> (above <85>% of total <total>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.154 |
| fcRawSpaceAllocation95Alert Total <FC> raw space usage at <ZZ> (above <95>% of total <total>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.155 |
| nlRawSpaceAllocation75Alert Total <NL> raw space usage at <space used> (above <75>% of total <total space>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.156 |
| nlRawSpaceAllocation85Alert Total <NL> raw space usage at <ZZ> (above <85>% of total <total>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.157 |
| nlRawSpaceAllocation95Alert Total <NL> raw space usage at <ZZ> (above <95>% of total <total>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.158 |
| ssdRawSpaceAllocation75Alert Total <SSD> raw space usage at <ZZ> (above <75>% of total <total>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.159 |
| componentStateChangeInternalConsistencyError Internal Consistency Error; Virtual Volume <vv_id>(<vv_name>) Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.16 |
| ssdRawSpaceAllocation85Alert Total <SSD> raw space usage at <space used> (above <85>% of total <total space>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.160 |
| ssdRawSpaceAllocation95Alert Total <SSD> raw space usage at <ZZ> (above <95>% of total <total>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.161 |
| preservedDataLdsAreFull Preserved data LDs are full. No more preserved data can be handled. | notification | - | .1.3.6.1.4.1.12925.1.2.0.162 |
| componentStateChangePowerSupplyFanWarning Power Supply Fan Warning; Cage <cage_id> Power Supply <power_supply_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.163 |
| componentStateChangePowerSupplyOff Power Supply Off; Cage <cage_id> Power Supply <power_supply_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.164 |
| componentStateChangePowerSupplyFailed0x02b00faX1 Power Supply Failed; Cage <cage_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.165 |
| componentStateChangePowerSupplyFailed0x02b00faX1026 Power Supply Failed; Cage <cage_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.166 |
| componentStateChangePowerSupplyWarning Power Supply Warning; Cage <cage_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.167 |
| componentStateChangePowerSupplyFanNotPresent Power Supply Fan Not Present; Cage <cage_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.168 |
| componentStateChangePowerSupplyFanNotAvailable Power Supply Fan Not Available; Cage <cage_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.169 |
| componentStateChangeNeedsToBeChecked Needs To Be Checked; Virtual Volume <vv_id>(<vv_name>) Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.17 |
| componentStateChangePowerSupplyNotAvailable Power Supply Not Available; Cage <cage_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.170 |
| componentStateChangePowerSupplyAcFailed Power Supply AC Failed; Cage <cage_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.171 |
| componentStateChangeInterfaceCardFailed0x02d00deX1026 Interface Card Failed; Cage <cage_id> Interface Card <interface_card_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.172 |
| componentStateChangeCpuFirmwareNotCurrent CPU Firmware Not Current; Cage <cage_id> Interface Card <interface_card_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.173 |
| componentStateChangeInterfaceCardFailed0x02d00faX1026 Interface Card Failed; Cage <cage_id> Interface Card <interface_card_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.174 |
| componentStateChangeInterfaceCardWarning Interface Card Warning; Cage <cage_id> Interface Card <interface_card_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.175 |
| componentStateChangeMissing0x03500faX1 Missing; Cage <cage_id> Magazine <mag_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.176 |
| componentStateChangeOffloopPowerSupplyFailure Offloop, Power Supply Failure; Cage <cage_id> Magazine <mag_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.177 |
| writeCacheAvailability System write cache availability is degraded. | notification | - | .1.3.6.1.4.1.12925.1.2.0.178 |
| componentStateChangeVolumeUnsyncedRequiresAFullResyncSinceLd Volume Unsynced - requires a full resync since ldck is in progress; Remote Copy Volume <volume_id>(<volume_name>) Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.179 |
| componentStateChangePreserved Preserved; Virtual Volume <vv_id>(<vv_name>) Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.18 |
| componentStateChangeResyncSnapshotBecameStaleFullSyncRequire Resync Snapshot Became Stale - full sync required; Remote Copy Volume <volume_id>(<volume_name>) Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.180 |
| componentStateChangeVolumeGroupUnsyncedDidNotTakeSnapshotsWh Volume Group Unsynced - did not take snapshots while stopping group; Remote Copy Volume <volume_id>(<volume_name>) Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.181 |
| componentStateChangeVolumeUnsyncedSecondaryVolumeWasNotMarke Volume Unsynced - secondary volume was not marked as in-sync; Remote Copy Volume <volume_id>(<volume_name>) Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.182 |
| componentStateChangeVolumeUnsyncedVolumeWasUnavailableWhenGr Volume Unsynced - volume was unavailable when group was stopped; Remote Copy Volume <volume_id>(<volume_name>) Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.183 |
| componentStateChangeVolumeUnsyncedNodeOrSysmgrFailure Volume Unsynced - node or sysmgr failure; Remote Copy Volume <volume_id>(<volume_name>) Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.184 |
| componentStateChangeVolumeUnsyncedPromoteOfSnapshotFailed Volume Unsynced - promote of snapshot failed; Remote Copy Volume <volume_id>(<volume_name>) Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.185 |
| componentStateChangeVolumeUnsyncedCouldNotTakeSnapshotDuring Volume Unsynced - could not take snapshot during sysmgr startup; Remote Copy Volume <volume_id>(<volume_name>) Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.186 |
| componentStateChangeWriteToSecondaryVolumeFailed Write To Secondary Volume Failed; Remote Copy Volume <volume_id>(<volume_name>) Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.187 |
| componentStateChangeSyncFailed Sync Failed; Remote Copy Volume <volume_id>(<volume_name>) Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.188 |
| componentStateChangeSyncFailedCouldNotTakeLocalSnapshots Sync Failed - could not take local snapshots; Remote Copy Volume Group <group_id>(<group_name>) Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.189 |
| componentStateChangeInvalid Invalid; Virtual Volume <vv_id>(<vv_name>) Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.19 |
| componentStateChangeSyncFailedCouldNotTakeRemoteSnapshots Sync Failed - could not take remote snapshots; Remote Copy Volume Group <group_id>(<group_name>) Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.190 |
| componentStateChangeSyncFailedCouldNotCommunicateWithTarget Sync Failed - could not communicate with target; Remote Copy Volume Group <group_id>(<group_name>) Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.191 |
| componentStateChangeSyncFailedSynchronizationSnapshotHasBeen Sync Failed - synchronization snapshot has been deleted; Remote Copy Volume Group <group_id>(<group_name>) Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.192 |
| componentStateChangeResyncFailedResynchronizationSnapshotHas Resync Failed - resynchronization snapshot has been deleted; Remote Copy Volume Group <group_id>(<group_name>) Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.193 |
| componentStateChangeNotAllVolumesInGroupAreInSync Not All Volumes In Group Are In Sync; Remote Copy Volume Group <group_id>(<group_name>) Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.194 |
| componentStateChangeResyncFailedVolumeIsCurrentlySyncing Resync Failed - volume is currently syncing; Remote Copy Volume Group <group_id>(<group_name>) Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.195 |
| componentStateChangeAllLinksToTargetAreDown All Links To Target Are Down; Remote Copy Target <target_id>(<target_name>) Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.196 |
| componentStateChangeNotAllConnectionsAreUp Not All Connections Are Up; Remote Copy Link <link_id>(<link_name>) Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.197 |
| componentStateChangeDownDueToSendErrorOrMissingHeartbeat Down Due To Send Error Or Missing Heartbeat; Remote Copy Link <link_id>(<link_name>) Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.198 |
| componentStateChangeMultipleLinkDownErrorsWithin24Hours Multiple Link Down Errors Within 24 Hours; Remote Copy Link <link_id>(<link_name>) Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.199 |
| fcPortError Port <portnum> Failed (Shutdown Due To Too Many Firmware Cores). | notification | - | .1.3.6.1.4.1.12925.1.2.0.2 |
| componentStateChangeStale Stale; Virtual Volume <vv_id>(<vv_name>) Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.20 |
| componentStateChangeLinkHasBeenDownForMoreThan4Hours Link Has Been Down For More Than 4 Hours; Remote Copy Link <link_id>(<link_name>) Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.200 |
| nodeDriveIsEncryptedButEncryptionIsNotEnabledOnTheSystem Node drive for node <hw_node> drive <driveid> with WWN <sw_wwn> has encryption enabled, but encryption is not enabled on the system. | notification | - | .1.3.6.1.4.1.12925.1.2.0.202 |
| encryptionIsEnabledOnTheSystemButTheNodeDriveIsNotEncrypted Node drive for node <hw_node> drive <driveid> with WWN <sw_wwn> is not encrypted, but encryption is enabled on the system. | notification | - | .1.3.6.1.4.1.12925.1.2.0.203 |
| unableToDoIOToTheNodeDrive Unable to do I/O to the node drive for node <hw_node> drive <driveid> with WWN <sw_wwn>. | notification | - | .1.3.6.1.4.1.12925.1.2.0.204 |
| syslogNodeDriveFailureMessageMonitoring [[hw_node]] syslog received dual boot drive failure message. Problem exists on device: <nodedrivesdxdev_name>, on sata port: <nodedrivesataport_name> | notification | - | .1.3.6.1.4.1.12925.1.2.0.205 |
| periodicProcMdstatMonitoringDetectedDegradedNodeDriveRaid [[hw_node]] /proc/mdstat detected degraded node drive raid. Problem exists on device: <nodedrivesdxdev_name>, on sata port: <nodedrivesataport_name> | notification | - | .1.3.6.1.4.1.12925.1.2.0.206 |
| processNameAppearsUnresponsive <name> appears to be unresponsive. | notification | - | .1.3.6.1.4.1.12925.1.2.0.207 |
| processEventHandlingAppearsUnresponsive <name> event handling appears to be unresponsive. | notification | - | .1.3.6.1.4.1.12925.1.2.0.208 |
| patrolDataCacheDimmUerr Node <node_id>, Data Cache DIMM <dimm_id> is failing. Uncorrectable Error. | notification | - | .1.3.6.1.4.1.12925.1.2.0.209 |
| ldskHasFailedSet LD <ld_id>(<ld_name>) row <ld_row> set <ld_set> failed. Internal reason <reason>. | notification | - | .1.3.6.1.4.1.12925.1.2.0.21 |
| controlCacheDimmTemperature Node <node_id> Control Cache DIMM <dimm_id> overheating (<temp> C). | notification | - | .1.3.6.1.4.1.12925.1.2.0.210 |
| componentStateChangeCageBatteryEndOfLife Cage Battery End of Life; Cage <cage_id> Cage Battery <battery_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.211 |
| componentStateChangeCageBatteryFailed Cage Battery Failed; Cage <cage_id> Cage Battery <battery_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.212 |
| componentStateChangeCageBatteryNotPresent Cage Battery Not Present; Cage <cage_id> Cage Battery <battery_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.213 |
| componentStateChangeNodeControlCacheDimmFailure Node Control Cache DIMM Failure; Node <node_id>, Contol_Cache_DIMM failed, <DIMM_INFO> (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.214 |
| componentStateChangeNodeDataCacheDimmFailure Node Data Cache DIMM Failure; Node <node_id>, Data_Cache_DIMM failed, <DIMM_INFO> (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.215 |
| componentStateChangeNodeIdeDriveFailure Node IDE Drive Failure; Node <node_id>, IDE_DRIVE failed, Instance: <dev_num> (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.216 |
| componentStateChangeNodeHbaFailure Node HBA Failure; Node <node_id>, HBA failed, Instance: <dev_num> (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.217 |
| sedIsFromTheWrongSystem A self-encrypting drive with WWN <sw_wwn> belongs to another system: <name> | notification | - | .1.3.6.1.4.1.12925.1.2.0.218 |
| sedHasTheWrongKey A self-encrypting drive with WWN <sw_wwn> has an unrecognized encryption key | notification | - | .1.3.6.1.4.1.12925.1.2.0.219 |
| ldAvailabilityHasReduced Some Logical Disks (LDs) in the system are running with reduced availability. | notification | - | .1.3.6.1.4.1.12925.1.2.0.22 |
| sedIsPresentButEncryptionIsNotEnabled A self-encrypting drive with WWN <sw_wwn> is encrypted, but encryption is not enabled on the system. | notification | - | .1.3.6.1.4.1.12925.1.2.0.220 |
| lkmIsInAnUnknownState The local Key Manager is in an invalid state | notification | - | .1.3.6.1.4.1.12925.1.2.0.221 |
| nodesvrUnresponsiveDuringDarsvrStartup The encryption management service is unavailable due to excessive failures getting encryption status from nodesvr during darsvr startup. If encryption is enabled on this system, d… | notification | - | .1.3.6.1.4.1.12925.1.2.0.222 |
| nodesvrUnresponsiveDuringFipsvrStartup The encryption management service is unavailable due to excessive failures getting encryption status from nodesvr during fipsvr startup. If encryption is enabled on this system, d… | notification | - | .1.3.6.1.4.1.12925.1.2.0.223 |
| fipsvrUnableToStartInFipsMode The encryption management service is unavailable because fipsvr failed to start up in FIPS mode. If encryption is enabled on this system, drive replacement is prevented and the sy… | notification | - | .1.3.6.1.4.1.12925.1.2.0.224 |
| failedToSuccessfullyCommunicateWithEkmAtStartup The encryption management service is unavailable because communication failed to the External Key Manager during startup. If encryption is enabled on this system, drive replacemen… | notification | - | .1.3.6.1.4.1.12925.1.2.0.225 |
| logLdRaidSetFailure Log [[ld]] has a failed raid set: <set_num>. Reason <reason>. | notification | - | .1.3.6.1.4.1.12925.1.2.0.23 |
| diskMonitorStopped pd wwn <pd_wwn> has failed for too long. Disk monitoring has stopped on this disk. | notification | - | .1.3.6.1.4.1.12925.1.2.0.24 |
| systemReporterPdPerformanceMajorAlert System Reporter threshold alert <pd_str_data> with condition <pd_valstr1> has been satisfied by pd <pd_valstr0> with value(s) <pd_valstr2>. | notification | - | .1.3.6.1.4.1.12925.1.2.0.25 |
| systemOvertemp System shutdown for over temp PDs, TOC quorum loss - <num> TOC drives are at or above their spin down temperatures. | notification | - | .1.3.6.1.4.1.12925.1.2.0.26 |
| diskOvertempButNotSpundown Physical Disk (PD) <pd_id> with World Wide Name (WWN) <pd_wwn> has exceeded its temperature threshold (<disk_temp> C, limit <thres_temp> C) but it could not be spundown. Location … | notification | - | .1.3.6.1.4.1.12925.1.2.0.27 |
| diskOvertempAndSpundown Physical Disk (PD) <pd_id> with World Wide Name (WWN) <pd_wwn> has exceeded its temperature threshold (<disk_temp> C, limit <thres_temp> C) and it has been spundown. Location (<ca… | notification | - | .1.3.6.1.4.1.12925.1.2.0.28 |
| diskOvertempButNotSpundownNoDsk Physical Disk with World Wide Name (WWN) <pd_wwn> has exceeded its temperature threshold (<disk_temp> C, limit <thres_temp> C) but it could not be spundown. Location (<cageid>:<ma… | notification | - | .1.3.6.1.4.1.12925.1.2.0.29 |
| portDeviceCountExceeded [[sw_port]], supported device count exceeded for port. | notification | - | .1.3.6.1.4.1.12925.1.2.0.3 |
| diskOvertempAndSpundownNoDsk Physical Disk with World Wide Name (WWN) <pd_wwn> has exceeded its temperature threshold (<disk_temp> C, limit <thres_temp> C) and it has been spundown. Location (<cageid>:<magid>… | notification | - | .1.3.6.1.4.1.12925.1.2.0.30 |
| componentStateChangeFailedHardware0x00600deX153 Failed Hardware; Magazine <mag_id> Physical Disk <pd_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.31 |
| componentStateChangeMediaFailed0x00600deX156 Media Failed; Magazine <mag_id> Physical Disk <pd_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.32 |
| componentStateChangeFailedHardware0x00600faX153 Failed Hardware; Magazine <mag_id> Physical Disk <pd_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.33 |
| componentStateChangeMediaFailed0x00600faX156 Media Failed; Magazine <mag_id> Physical Disk <pd_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.34 |
| componentStateChangeReplaceDrive0x00600faX70 Replace Drive; Magazine <mag_id> Physical Disk <pd_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.35 |
| doubleNodeFailure System is not able to recover from double node failure. | notification | - | .1.3.6.1.4.1.12925.1.2.0.36 |
| nodeRecoveryPowerfailEvent Node recovery requires a powerfail to continue | notification | - | .1.3.6.1.4.1.12925.1.2.0.37 |
| licenseKeyUsageLicenseExpired License feature <feature_name> has expired. You are in violation of your
3PAR License Agreement. | notification | - | .1.3.6.1.4.1.12925.1.2.0.38 |
| systemRecoveryNotificationAboutBadVolume Powerfail recovery could not be performed for volume <prb_vname> with id <prb_vvid>. This may have caused loss of data for that volume. Use checkvv to check and fix the volume met… | notification | - | .1.3.6.1.4.1.12925.1.2.0.39 |
| diskPortHasExceededIoErrorThreshold Disk [[sw_port]] has exceeded a threshold tracking IO errors. <count> errors have been seen in one hour. | notification | - | .1.3.6.1.4.1.12925.1.2.0.4 |
| batteryStates Battery states could not be read from the configuration file. System cache is disabled. | notification | - | .1.3.6.1.4.1.12925.1.2.0.40 |
| systemRecoveryStalledDueToUnstartedVvs System recovery stalled due to unstarted vvs. Num vvs: <pfs_num_vvs>. | notification | - | .1.3.6.1.4.1.12925.1.2.0.41 |
| unexpectedEncryptionStateOnNodeDrive System is waiting for the encryption state of nodes <wait_nodes> to become valid. If this state persists, check existing alerts for more information. | notification | - | .1.3.6.1.4.1.12925.1.2.0.42 |
| ideDiskErrorNodeShutdown Node <nid> is being shutdown by the system because it had internal drive errors. | notification | - | .1.3.6.1.4.1.12925.1.2.0.43 |
| ideDiskErrorNodeNotShutdown Node <nid> is not being shutdown by the system even though there are internal drive errors because it is the last node left alive. | notification | - | .1.3.6.1.4.1.12925.1.2.0.44 |
| ideDiskErrorNodeNotShutdownLdsCannotBeServed Node <nid> is not being shutdown by the system even though there are internal drive errors because some LDs cannot be served by the remaining nodes. | notification | - | .1.3.6.1.4.1.12925.1.2.0.45 |
| ideDiskErrorNodeReboot Node <nid> is being rebooted by the system because it had internal drive errors. | notification | - | .1.3.6.1.4.1.12925.1.2.0.46 |
| authenticationFailure <number of fails> authentication failures in <n> secs | notification | - | .1.3.6.1.4.1.12925.1.2.0.47 |
| nodeIsOffline Node <node_id> is offline | notification | - | .1.3.6.1.4.1.12925.1.2.0.48 |
| memoryUsageInformation Memory usage critical: MemTotal: <memtotal>K MemFree: <memfree>K Buffers: <buffers>K Cached: <cached>K SwapCached: <swapcached>K Active: <active>K Inactive: <inactive>K SwapTotal:… | notification | - | .1.3.6.1.4.1.12925.1.2.0.49 |
| componentStateChangeTargetModePortWentOffline Target Mode Port Went Offline; Port <node>:<slot>:<port> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.5 |
| clusterThermalShutdown Node <Node_ID>, due to high temperature conditions, the storage system is being shutdown. | notification | - | .1.3.6.1.4.1.12925.1.2.0.50 |
| nodeNeedsToShutdown THERMAL SHUTDOWN, node: <node_id> | notification | - | .1.3.6.1.4.1.12925.1.2.0.51 |
| slabMemoryUsageOverLimit SlabUsage:: critical status=<report_status> Totals:: memory=<slab_tot_mem_kb>KB count=<slab_tot_ct> activeCount=<slab_tot_active_ct> largestUseSlabs(count=<slab_entry_ct>)::<slab_… | notification | - | .1.3.6.1.4.1.12925.1.2.0.52 |
| systemReporterCmpPerformanceMajorAlert System Reporter threshold alert <cmp_str_data> with condition <cmp_valstr1> has been satisfied by cmp on node <cmp_valstr0> with value(s) <cmp_valstr2>. | notification | - | .1.3.6.1.4.1.12925.1.2.0.53 |
| systemReporterCpuPerformanceMajorAlert System Reporter threshold alert <cpu_str_data> with condition <cpu_valstr1> has been satisfied by cpu on node <cpu_valstr0> with value(s) <cpu_valstr2>. | notification | - | .1.3.6.1.4.1.12925.1.2.0.54 |
| systemReporterLinkPerformanceMajorAlert System Reporter threshold alert <link_str_data> with condition <link_valstr1> has been satisfied by link on node <link_valstr0> with value(s) <link_valstr2>. | notification | - | .1.3.6.1.4.1.12925.1.2.0.55 |
| cmpThreshold CMP usage on node [[hw_node]] has exceeded <threshold>%. | notification | - | .1.3.6.1.4.1.12925.1.2.0.56 |
| systemReporterCachePerformanceMajorAlert System Reporter threshold alert <cache_str_data> with condition <cache_valstr1> has been satisfied by cache on node <cache_valstr0> with value(s) <cache_valstr2>. | notification | - | .1.3.6.1.4.1.12925.1.2.0.57 |
| componentStateChangeTimeOfDayBatteryFailure Time-Of-Day Battery Failure; Node <node_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.58 |
| componentStateChangeCpuOverheating CPU Overheating; Node <node_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.59 |
| componentStateChangeTooManyInitiators Too many initiators; Port <node>:<slot>:<port> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.6 |
| componentStateChangeNodeOfflineDueToFailure0x01a00deX13 Node Offline Due to Failure; Node <node_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.60 |
| componentStateChangeCpuDead0x01a00deX19 CPU Dead; Node <node_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.61 |
| componentStateChangeNodeFanModule0Failed0x01a00deX25 Node Fan Module 0 Failed; Node <node_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.62 |
| componentStateChangeNodeFanModule0PowerFault0x01a00deX28 Node Fan Module 0 Power Fault; Node <node_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.63 |
| componentStateChangeNodeFanModule0UnderLimit Node Fan Module 0 Under Limit; Node <node_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.64 |
| componentStateChangeNodeThermalState Node Thermal State; Node <node_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.65 |
| componentStateChangeNodeFanModule1Failed0x01a00deX33 Node Fan Module 1 Failed; Node <node_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.66 |
| componentStateChangeNodeFanModule1PowerFault0x01a00deX35 Node Fan Module 1 Power Fault; Node <node_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.67 |
| componentStateChangeNodeOfflineDueToFailure0x01a00faX13 Node Offline Due to Failure; Node <node_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.68 |
| componentStateChangeCpuDead0x01a00faX19 CPU Dead; Node <node_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.69 |
| metadataInconsistencyInAVv [[vvol]] Volume not started due to metadata inconsistency; manual check required. | notification | - | .1.3.6.1.4.1.12925.1.2.0.7 |
| componentStateChangeNodeFanModule0Failed0x01a00faX25 Node Fan Module 0 Failed; Node <node_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.70 |
| componentStateChangeNodeFanModule0PowerFault0x01a00faX28 Node Fan Module 0 Power Fault; Node <node_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.71 |
| componentStateChangeUncorrectableMemoryError Uncorrectable Memory Error; Node <node_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.72 |
| componentStateChangeNodeThermalShutdown Node Thermal Shutdown; Node <node_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.73 |
| componentStateChangeNodeFanModule1Failed0x01a00faX33 Node Fan Module 1 Failed; Node <node_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.74 |
| componentStateChangeNodeFanModule1PowerFault0x01a00faX35 Node Fan Module 1 Power Fault; Node <node_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.75 |
| componentStateChangeMultipleUncorrectableMemoryError Multiple Uncorrectable Memory Error; Node <node_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.76 |
| componentStateChangeDcFailed0x01b00faX1 DC Failed; Node <node_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.77 |
| componentStateChangeOverTemperature Over Temperature; Node <node_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.78 |
| componentStateChangeAcFailed AC Failed; Node <node_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.79 |
| vlmapCountExceedsThreshold VV <vv_name> (<vv_id>) exceeds vlmap count threshold 80% : AR1 <count> AR5 <count> AR5_SEC <count> USR <count> | notification | - | .1.3.6.1.4.1.12925.1.2.0.8 |
| componentStateChangeFanFailed0x01b00faX3 Fan Failed; Node <node_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.80 |
| componentStateChangeTemperatureUnderWarningThreshold0x01e00deX1 Temperature Under Warning Threshold; Cage <cage_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.81 |
| componentStateChangeOperatorsPanelFailed Operators Panel Failed; Cage <cage_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.82 |
| componentStateChangeOperatorsPanelWarning Operators Panel Warning; Cage <cage_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.83 |
| componentStateChangeUnsupportedCage Unsupported Cage; Cage <cage_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.84 |
| componentStateChangeTemperatureUnderWarningThreshold0x01e00faX1 Temperature Under Warning Threshold; Cage <cage_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.85 |
| componentStateChangeTemperatureUnderFailureThreshold Temperature Under Failure Threshold; Cage <cage_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.86 |
| componentStateChangeTemperatureOverWarningThreshold Temperature Over Warning Threshold; Cage <cage_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.87 |
| componentStateChangeInaccessible Inaccessible; Cage <cage_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.88 |
| componentStateChangeTemperatureOverFailureThreshold Temperature Over Failure Threshold; Cage <cage_id> Failed (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.89 |
| flashcachePerformanceDegradation Flash Cache I/O times are slow on node: <node>. | notification | - | .1.3.6.1.4.1.12925.1.2.0.9 |
| componentStateChangePortBypassed Port Bypassed; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.90 |
| componentStateChangeNotready Notready; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.91 |
| componentStateChangeMissing0x01f00deX129 Missing; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.92 |
| componentStateChangeInvalidConnections Invalid connections; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.93 |
| componentStateChangeNotAvailableForAllocations Not Available For Allocations; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.94 |
| componentStateChangeOldFirmware Old Firmware; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.95 |
| componentStateChangeDisabledAPort Disabled A Port; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.96 |
| componentStateChangeMissingAPort Missing A Port; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.97 |
| componentStateChangeErrorsOnAPort Errors on A Port; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.98 |
| componentStateChangeProlongedMissingAPort Prolonged Missing A Port; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | notification | - | .1.3.6.1.4.1.12925.1.2.0.99 |
| checkSnmpAlert check snmp test alert | notification | - | .1.3.6.1.4.1.12925.1.2.0.9999 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| component The component which the event applies to; for example,
power supply, SCSI disk, BIOS, cage etc... | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12925.1.7.1.5 |
| details Additional detailed description of the alert. The detail
may include things like disk number, cage number the alert
applies to. | column | OctetString | .1.3.6.1.4.1.12925.1.7.1.6 |
| nodeID The node the alert was posted on. The node number starts
from 0. The maximum number of node is 32. | column | Unsigned32 | .1.3.6.1.4.1.12925.1.7.1.4 |
| severity Severity of the alert. The enumeration is borrowed from
Common Information Model (CIM): 0 - fatal: indicates an
error occurred, but it's too late to take any actions; 1 -
critica… | column | Enumeration | .1.3.6.1.4.1.12925.1.7.1.2 |
| timeOccurred The local time and date when the alert occurred. The
format is '%Y-%m-%d %H:%M:%S %Z'.
Where:
%Y - year including century, %m - two digit month,
%d - two digit day of month, %H -… | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12925.1.7.1.3 |
| id Unique ID that identifies the instance of an alert. This
is a unique number that is generated each time an alert is
generated by the system. | column | Unsigned32 | .1.3.6.1.4.1.12925.1.7.1.7 |
| messageCode Message code is assigned to a particular event type, and is
encoded as a 32-bit number in the following way:
The MSB 8 bits are reserved.
The next 8 bits represent a particular su… | column | Unsigned32 | .1.3.6.1.4.1.12925.1.7.1.8 |
| state This provides information about the state of the alert.
new - new alert generated by the system
acknowledged - an administrator has acknowledged the alert but may
o… | column | Enumeration | .1.3.6.1.4.1.12925.1.7.1.9 |
| serialNumber The serial-number of the HPE 3PAR InServ system | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12925.1.7.1.10 |
| tier The event tier. It provides more details on the type of event. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12925.1.7.1.13 |
| sparePartNumber The spare part number from events in the Hardware replacement or Hardware check tiers. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12925.1.7.1.14 |
| sysName The name of the storage system. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12925.1.7.1.15 |