nodeID
ThreeParMIB ·
.1.3.6.1.4.1.12925.1.7.1.4
Object
column
Unsigned32
The node the alert was posted on. The node number starts from 0. The maximum number of node is 32.
Context
- MIB
- ThreeParMIB
- OID
.1.3.6.1.4.1.12925.1.7.1.4- Type
- column
- Access
- readonly
- Status
- current
- Parent
- alertEntry
- Table
- alertTable
- Siblings
- 14
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 0-31
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| index Index to access entries in alert table. However, the table is
empty most of the time because the entry is deleted after sending
the trap | column | Integer32 | .1.3.6.1.4.1.12925.1.7.1.1 |
| serialNumber The serial-number of the HPE 3PAR InServ system | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12925.1.7.1.10 |
| catalogKey The extension of the message code. It's used for the lookup of HPGT information. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12925.1.7.1.11 |
| detailedMessage The extension of the details. It provides more specific details of error condition. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12925.1.7.1.12 |
| tier The event tier. It provides more details on the type of event. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12925.1.7.1.13 |
| sparePartNumber The spare part number from events in the Hardware replacement or Hardware check tiers. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12925.1.7.1.14 |
| sysName The name of the storage system. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12925.1.7.1.15 |
| severity Severity of the alert. The enumeration is borrowed from
Common Information Model (CIM): 0 - fatal: indicates an
error occurred, but it's too late to take any actions; 1 -
critica… | column | Enumeration | .1.3.6.1.4.1.12925.1.7.1.2 |
| timeOccurred The local time and date when the alert occurred. The
format is '%Y-%m-%d %H:%M:%S %Z'.
Where:
%Y - year including century, %m - two digit month,
%d - two digit day of month, %H -… | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12925.1.7.1.3 |
| component The component which the event applies to; for example,
power supply, SCSI disk, BIOS, cage etc... | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12925.1.7.1.5 |
| details Additional detailed description of the alert. The detail
may include things like disk number, cage number the alert
applies to. | column | OctetString | .1.3.6.1.4.1.12925.1.7.1.6 |
| id Unique ID that identifies the instance of an alert. This
is a unique number that is generated each time an alert is
generated by the system. | column | Unsigned32 | .1.3.6.1.4.1.12925.1.7.1.7 |
| messageCode Message code is assigned to a particular event type, and is
encoded as a 32-bit number in the following way:
The MSB 8 bits are reserved.
The next 8 bits represent a particular su… | column | Unsigned32 | .1.3.6.1.4.1.12925.1.7.1.8 |
| state This provides information about the state of the alert.
new - new alert generated by the system
acknowledged - an administrator has acknowledged the alert but may
o… | column | Enumeration | .1.3.6.1.4.1.12925.1.7.1.9 |