sdpLspRevertTimeCountDown

TN-SDP-MIB · .1.3.6.1.4.1.7483.6.1.2.4.4.3.1.48

Object

column seconds Integer32
The value of sdpLspRevertTimeCountDown indicated the timer
countdown before reverting back from LDP on this SDP.
The timer countdown begins after the first configured LSP
becomes active.
              
The value of -1 indicates when the revert time countdown
is not applicable.

Context

MIB
TN-SDP-MIB
OID
.1.3.6.1.4.1.7483.6.1.2.4.4.3.1.48
Type
column
Access
readonly
Status
current
Units
seconds
Parent
sdpInfoEntry
Table
sdpInfoTable
Siblings
58

Syntax

seconds Integer32

Values & Constraints

Object Constraints
range: -1-600

Related Objects

Sibling Objects