tnDot1agCfmMepSlmOWTestStatus

TN-IEEE8021-CFM-MIB · .1.3.6.1.4.1.7483.6.1.2.52.7.6.1.1

Object

column r/w TN-TC-MIBTmnxEnabledDisabled
The value of tnDot1agCfmMepSlmOWTestStatus specifies the operational
state of the one-way Synthetic Loss Measurement (SLM) test.
              
To issue a one-way SLM test the user must issue an SNMP SET on this
object with a value 'enabled (1)'. To abort the one-way SLM test issue
an SNMP SET on this object with the value 'disabled (2)'.
              
A read on this object represents the current state of the one-way SLM
test:
    enabled  (1)  - The test is actively running, and attempts at
                    modifying any one-way SLM object will be rejected
    disabled (2)  - The test is not running.
              
Once the test is complete this object will revert to the default value
'disabled (2)'.

Context

MIB
TN-IEEE8021-CFM-MIB
OID
.1.3.6.1.4.1.7483.6.1.2.52.7.6.1.1
Type
column
Access
readwrite
Status
current
Parent
tnDot1agCfmMepSlmOWTestEntry
Table
tnDot1agCfmMepSlmOWTestTable
Siblings
6

Syntax

TN-TC-MIBTmnxEnabledDisabled
Source
TN-TC-MIBTmnxEnabledDisabled
Base type
Enumeration

Values & Constraints

Type Values
1enabled
2disabled

Related Objects

Sibling Objects