tmnxSubAuthPlcyRadAuthDownTime

TIMETRA-SUBSCRIBER-MGMT-MIB · .1.3.6.1.4.1.6527.3.1.2.33.1.1.1.30

Object

column r/w seconds Unsigned32
The value of tmnxSubAuthPlcyRadAuthDownTime specifies the hold down
time.
              
If a RADIUS authentication server that was considered 'down' becomes
responsive again, the system waits for this amount of time before it
starts to address that server again.

Context

MIB
TIMETRA-SUBSCRIBER-MGMT-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.33.1.1.1.30
Type
column
Access
readwrite
Status
current
Units
seconds
Parent
tmnxSubAuthPlcyEntry
Table
tmnxSubAuthPlcyTable
Siblings
40

Syntax

seconds Unsigned32

Values & Constraints

Object Constraints
range: 30-900

Related Objects

Sibling Objects