tmnxOesTempLowClear
TIMETRA-OES-HARDWARE-MIB ·
.1.3.6.1.4.1.6527.3.1.3.99.1.29
Object
notification
[CAUSE] The tmnxOesFanSpeedLowClear notification is generated when the
card has indicated its temperature is within operational limits.
[EFFECT] The card resumes normal operation state.
[RECOVERY] No recovery is required.
Context
- MIB
- TIMETRA-OES-HARDWARE-MIB
- OID
.1.3.6.1.4.1.6527.3.1.3.99.1.29- Type
- notification
- Status
- current
- Parent
- tmnxOesHwNotifications
- Siblings
- 31
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tmnxOesCtlCardPortDown [CAUSE] The tmnxOesCtlCardPortDown notification is generated when a
port (e.g. ES 1 or AUX) on an OES Control Card (e.g. EC card) is not
operational. The reason may be a misconn… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.1 |
| tmnxOesFanFailureClear [CAUSE] The tmnxOesFanFailureClear notification is generated when fan
failure in an OES chassis is cleared. tmnxOesNotifyFailureReason contains
the reason for fan failure being cl… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.10 |
| tmnxOesPowerSupplyRemoved [CAUSE] The tmnxOesPowerSupplyRemoved notification is generated when
an OES power supply unit is removed from its slot in the OES chassis.
[EFFECT] The power supply … | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.11 |
| tmnxOesPowerSupplyInserted [CAUSE] The tmnxOesPowerSupplyInserted notification is generated when
the OES power supply unit is inserted into its slot in the OES chassis.
[EFFECT] The indicated … | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.12 |
| tmnxOesPowerSupplyFailure [CAUSE] The tmnxOesPowerSupplyFailure notification is generated when
the power supply unit in the indicated slot of the OES chassis has
failed. tmnxOesNotifyFailureReason contai… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.13 |
| tmnxOesPowerSupplyFailureClear [CAUSE] The tmnxOesPowerSupplyFailureClear notification is generated
when the power supply failure in the indicated slot of the OES chassis
is cleared. tmnxOesNotifyFailureReaso… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.14 |
| tmnxOesPortError [CAUSE] The tmnxOesPortError notification is generated when an error
condition listed in tmnxOesPortNotifyError is detected on the OES port.
[EFFECT] The OES port is e… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.15 |
| tmnxOesPortErrorClear [CAUSE] The tmnxOesPortErrorClear notification is generated when
all error conditions on the OES port are cleared.
[EFFECT] The OES port error conditions are cleared.
… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.16 |
| tmnxOesCtlCardActivityChange [CAUSE] The tmnxOesCtlCardActivityChange notification is generated
when the active Equipment Controller has changed to the card
specified by the tmnxHwIndex.
[EFFECT]… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.17 |
| tmnxOesFpgaFail [CAUSE] The tmnxOesFpgaFail notification is generated during an
out-of-service upgrade when the FPGA file downloaded to the card was
corrupt or the FPGA failed to program correct… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.18 |
| tmnxOesFpgaFailClear [CAUSE] The tmnxOesFpgaFailClear notification is generated when the
FPGA is successfully programmed.
[EFFECT] The FPGA is successfully programmed.
[RECOVE… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.19 |
| tmnxOesCtlCardPortUp [CAUSE] The tmnxOesCtlCardPortUp notification is generated when the
port on the OES Control Card (e.g. EC card) is operational.
[EFFECT] If an ES port is up then a con… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.2 |
| tmnxOesFpgaTimeout [CAUSE] The tmnxOesFpgaTimeout notification is generated when the FPGA
file download and reprogramming took longer than expected (about 45
minutes).
[EFFECT] The FPG… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.20 |
| tmnxOesFpgaTimeoutClear [CAUSE] The tmnxOesFpgaTimeoutClear notification is generated
when the OES FPGA timeout condition is cleared.
[EFFECT] The FPGA is successfully programmed.
… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.21 |
| tmnxOesOptTrnspndrMiscFail [CAUSE] The tmnxOesOptTrnspndrMiscFail notification is generated when
a non-service affecting hardware defect is detected on the card.
This condition may be declared on the card… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.22 |
| tmnxOesCardDegraded [CAUSE] The tmnxOesCardDegraded notification is generated when a fault
on the card has caused the system to declare a hardware failure.
This condition may be declared due to a f… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.23 |
| tmnxOesFanSpeedHigh [CAUSE] The tmnxOesFanSpeedHigh notification is generated when the fan
speed is too high, based upon the current shelf cooling requirements.
[EFFECT] The fans run faste… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.24 |
| tmnxOesFanSpeedHighClear [CAUSE] The tmnxOesFanSpeedHighClear notification is generated when
the conditions causing a tmnxOesFanSpeedHigh notification have been
cleared. Fan speed has returned to accept… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.25 |
| tmnxOesFanSpeedLow [CAUSE] The tmnxOesFanSpeedLow notification is generated when the fan
speed is too low, based upon the current shelf cooling requirements.
[EFFECT] The fans run slower… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.26 |
| tmnxOesFanSpeedLowClear [CAUSE] The tmnxOesFanSpeedLowClear notification is generated when the
conditions causing a tmnxOesFanSpeedLow notification have been cleared.
Fan speed has returned to acceptab… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.27 |
| tmnxOesTempLow [CAUSE] The tmnxOesTempLow notification is generated when the card
has detected its temperature is below operational limits.
[EFFECT] The card performance may degrade … | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.28 |
| tmnxOesUsrpnlPortDown [CAUSE] The tmnxOesUsrpnlPortDown notification is generated when
a port (E1 or E2) on an OES USRPNL card is not operational. The
reason may be a misconnected, disconnected or fau… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.3 |
| tmnxOesRedundancyFail [CAUSE] The tmnxOesRedundancyFail notification is generated when the
inactive equipment controller card in the OES is not providing
redundancy protection. In some cases this is … | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.30 |
| tmnxOesRedundancyReady [CAUSE] The tmnxOesRedundancyReady notification is generated when the
equipment controller cards in the indicated OES chassis are providing
redundant protection. The equipment c… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.31 |
| tmnxOesCardFirmwareErr [CAUSE] The tmnxOesCardFirmwareErr is raised when
the device installed in the shelf has an EEPROM that does not contain
the correct or recognizable information.
[EFFE… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.33 |
| tmnxOesUsrpnlPortUp [CAUSE] The tmnxOesUsrpnlPortUp notification is generated when the
OES USRPNL port is now operational.
[EFFECT] If an E1 or E2 port is up then a control plane commun… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.4 |
| tmnxOesFanRemoved [CAUSE] The tmnxOesFanRemoved notification is generated when the OES
fan unit is removed from its slot in the OES chassis.
[EFFECT] The function of OES fan unit is no… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.5 |
| tmnxOesFanInserted [CAUSE] The tmnxOesFanInserted notification is generated when the OES
fan unit is inserted into its slot in the OES chassis.
[EFFECT] The OES chassis is now equipped … | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.6 |
| tmnxOesFan32HReqd [CAUSE] The tmnxOesFan32HReqd notification is generated when the
OES chassis in a PSS32 shelf requires high speed fan (FAN32H), but the
fan inserted is not the right type.
… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.7 |
| tmnxOesFan32HReqdClear [CAUSE] The tmnxOesFan32HReqdClear notification is generated when the
OES chassis is equipped with FAN32H or when the alarmed fan unit with
tmnxOesFan32HReqd condition is removed… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.8 |
| tmnxOesFanFailure [CAUSE] The tmnxOesFanFailure notification is generated when the fan
unit in an OES chassis has failed. tmnxOesNotifyFailureReason contains
the reason for fan failure.
… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| TIMETRA-CHASSIS-MIBtmnxHwClass The value of tmnxHwClass indicates the general hardware type of this
component. If no appropriate enumeration exists for this hardware
identify this hardware component then the … | column | TmnxHwClass | .1.3.6.1.4.1.6527.3.1.2.2.1.8.1.7 |