tmnxOesCtlCardPortDown
TIMETRA-OES-HARDWARE-MIB ·
.1.3.6.1.4.1.6527.3.1.3.99.1.1
Object
notification
[CAUSE] The tmnxOesCtlCardPortDown notification is generated when a
port (e.g. ES 1 or AUX) on an OES Control Card (e.g. EC card) is not
operational. The reason may be a misconnected, disconnected or faulty
cable, a faulty port or Control Card.
[EFFECT] If an ES (Extension Shelf) port is down then one of the
control plane communication paths between EC (Equipment Controller)
cards in different OES Chassis is not available. The control
communications with one or more OES subtending chassis may be
affected rendering the Chassis unmanageable. Other control paths
may be available.
If an AUX port is down then one of the control plane communication
paths between the router and the OES Master Chassis is not available
and control communications with the OES may be affected rendering
the OES unmanageable. Other control paths may be available.
[RECOVERY] Check that the cable is correctly connected and test the
cable.
Context
- MIB
- TIMETRA-OES-HARDWARE-MIB
- OID
.1.3.6.1.4.1.6527.3.1.3.99.1.1- Type
- notification
- Status
- current
- Parent
- tmnxOesHwNotifications
- Siblings
- 31
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tmnxOesFanFailureClear [CAUSE] The tmnxOesFanFailureClear notification is generated when fan
failure in an OES chassis is cleared. tmnxOesNotifyFailureReason contains
the reason for fan failure being cl… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.10 |
| tmnxOesPowerSupplyRemoved [CAUSE] The tmnxOesPowerSupplyRemoved notification is generated when
an OES power supply unit is removed from its slot in the OES chassis.
[EFFECT] The power supply … | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.11 |
| tmnxOesPowerSupplyInserted [CAUSE] The tmnxOesPowerSupplyInserted notification is generated when
the OES power supply unit is inserted into its slot in the OES chassis.
[EFFECT] The indicated … | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.12 |
| tmnxOesPowerSupplyFailure [CAUSE] The tmnxOesPowerSupplyFailure notification is generated when
the power supply unit in the indicated slot of the OES chassis has
failed. tmnxOesNotifyFailureReason contai… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.13 |
| tmnxOesPowerSupplyFailureClear [CAUSE] The tmnxOesPowerSupplyFailureClear notification is generated
when the power supply failure in the indicated slot of the OES chassis
is cleared. tmnxOesNotifyFailureReaso… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.14 |
| tmnxOesPortError [CAUSE] The tmnxOesPortError notification is generated when an error
condition listed in tmnxOesPortNotifyError is detected on the OES port.
[EFFECT] The OES port is e… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.15 |
| tmnxOesPortErrorClear [CAUSE] The tmnxOesPortErrorClear notification is generated when
all error conditions on the OES port are cleared.
[EFFECT] The OES port error conditions are cleared.
… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.16 |
| tmnxOesCtlCardActivityChange [CAUSE] The tmnxOesCtlCardActivityChange notification is generated
when the active Equipment Controller has changed to the card
specified by the tmnxHwIndex.
[EFFECT]… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.17 |
| tmnxOesFpgaFail [CAUSE] The tmnxOesFpgaFail notification is generated during an
out-of-service upgrade when the FPGA file downloaded to the card was
corrupt or the FPGA failed to program correct… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.18 |
| tmnxOesFpgaFailClear [CAUSE] The tmnxOesFpgaFailClear notification is generated when the
FPGA is successfully programmed.
[EFFECT] The FPGA is successfully programmed.
[RECOVE… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.19 |
| tmnxOesCtlCardPortUp [CAUSE] The tmnxOesCtlCardPortUp notification is generated when the
port on the OES Control Card (e.g. EC card) is operational.
[EFFECT] If an ES port is up then a con… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.2 |
| tmnxOesFpgaTimeout [CAUSE] The tmnxOesFpgaTimeout notification is generated when the FPGA
file download and reprogramming took longer than expected (about 45
minutes).
[EFFECT] The FPG… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.20 |
| tmnxOesFpgaTimeoutClear [CAUSE] The tmnxOesFpgaTimeoutClear notification is generated
when the OES FPGA timeout condition is cleared.
[EFFECT] The FPGA is successfully programmed.
… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.21 |
| tmnxOesOptTrnspndrMiscFail [CAUSE] The tmnxOesOptTrnspndrMiscFail notification is generated when
a non-service affecting hardware defect is detected on the card.
This condition may be declared on the card… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.22 |
| tmnxOesCardDegraded [CAUSE] The tmnxOesCardDegraded notification is generated when a fault
on the card has caused the system to declare a hardware failure.
This condition may be declared due to a f… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.23 |
| tmnxOesFanSpeedHigh [CAUSE] The tmnxOesFanSpeedHigh notification is generated when the fan
speed is too high, based upon the current shelf cooling requirements.
[EFFECT] The fans run faste… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.24 |
| tmnxOesFanSpeedHighClear [CAUSE] The tmnxOesFanSpeedHighClear notification is generated when
the conditions causing a tmnxOesFanSpeedHigh notification have been
cleared. Fan speed has returned to accept… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.25 |
| tmnxOesFanSpeedLow [CAUSE] The tmnxOesFanSpeedLow notification is generated when the fan
speed is too low, based upon the current shelf cooling requirements.
[EFFECT] The fans run slower… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.26 |
| tmnxOesFanSpeedLowClear [CAUSE] The tmnxOesFanSpeedLowClear notification is generated when the
conditions causing a tmnxOesFanSpeedLow notification have been cleared.
Fan speed has returned to acceptab… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.27 |
| tmnxOesTempLow [CAUSE] The tmnxOesTempLow notification is generated when the card
has detected its temperature is below operational limits.
[EFFECT] The card performance may degrade … | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.28 |
| tmnxOesTempLowClear [CAUSE] The tmnxOesFanSpeedLowClear notification is generated when the
card has indicated its temperature is within operational limits.
[EFFECT] The card resumes norma… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.29 |
| tmnxOesUsrpnlPortDown [CAUSE] The tmnxOesUsrpnlPortDown notification is generated when
a port (E1 or E2) on an OES USRPNL card is not operational. The
reason may be a misconnected, disconnected or fau… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.3 |
| tmnxOesRedundancyFail [CAUSE] The tmnxOesRedundancyFail notification is generated when the
inactive equipment controller card in the OES is not providing
redundancy protection. In some cases this is … | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.30 |
| tmnxOesRedundancyReady [CAUSE] The tmnxOesRedundancyReady notification is generated when the
equipment controller cards in the indicated OES chassis are providing
redundant protection. The equipment c… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.31 |
| tmnxOesCardFirmwareErr [CAUSE] The tmnxOesCardFirmwareErr is raised when
the device installed in the shelf has an EEPROM that does not contain
the correct or recognizable information.
[EFFE… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.33 |
| tmnxOesUsrpnlPortUp [CAUSE] The tmnxOesUsrpnlPortUp notification is generated when the
OES USRPNL port is now operational.
[EFFECT] If an E1 or E2 port is up then a control plane commun… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.4 |
| tmnxOesFanRemoved [CAUSE] The tmnxOesFanRemoved notification is generated when the OES
fan unit is removed from its slot in the OES chassis.
[EFFECT] The function of OES fan unit is no… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.5 |
| tmnxOesFanInserted [CAUSE] The tmnxOesFanInserted notification is generated when the OES
fan unit is inserted into its slot in the OES chassis.
[EFFECT] The OES chassis is now equipped … | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.6 |
| tmnxOesFan32HReqd [CAUSE] The tmnxOesFan32HReqd notification is generated when the
OES chassis in a PSS32 shelf requires high speed fan (FAN32H), but the
fan inserted is not the right type.
… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.7 |
| tmnxOesFan32HReqdClear [CAUSE] The tmnxOesFan32HReqdClear notification is generated when the
OES chassis is equipped with FAN32H or when the alarmed fan unit with
tmnxOesFan32HReqd condition is removed… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.8 |
| tmnxOesFanFailure [CAUSE] The tmnxOesFanFailure notification is generated when the fan
unit in an OES chassis has failed. tmnxOesNotifyFailureReason contains
the reason for fan failure.
… | notification | - | .1.3.6.1.4.1.6527.3.1.3.99.1.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tmnxOesCmnEqpPortOperStatus The value of tmnxOesCmnEqpPortOperStatus indicates the operational
status of the port of the OES common equipment card. | column | TIMETRA-PORT-MIBTmnxPortOperStatus | .1.3.6.1.4.1.6527.3.1.2.99.3.1.1.3 |