controlTrapReceiverTable
TELESTE-COMMON-MIB ·
.1.3.6.1.4.1.3715.99.1.3.5
Object
table
optional
A table of manager trap receiver addresses, ports and
communities. Total number of entries can not exceed
elementNumberTrapReceivers. An entry is deleted from this
table by setting its IP address to '0.0.0.0'.
Note: one of the community strings must match to
commonTrapCommunityString in SCTE-HMS-COMMON-MIB, if
that is implemented.
Context
- MIB
- TELESTE-COMMON-MIB
- OID
.1.3.6.1.4.1.3715.99.1.3.5- Type
- table
- Status
- optional
- Parent
- elementControl
- Siblings
- 10
- Children
- 1
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| controlResetElement mandatory On write requests this object commands the module to
reset itself.
If softReset(3) or hardReset(2) can not be performed,
then BAD VALUE error is returned.
O… | scalar | Enumeration | .1.3.6.1.4.1.3715.99.1.3.1 |
| controlAlarmOffDelay optional The minimum time an alarm/warning entry stays active after
the object has reached it's normal condition. Common to all
alarms/warnings.
- Unit 10 ms
- Minimum value 10 (100 ms)
- … | scalar | Integer32 | .1.3.6.1.4.1.3715.99.1.3.10 |
| controlTrapDelay optional The time before a trap is sent after an alarm
is detected.
- Unit 10 ms
- Minimum value 10 (100 ms)
- Maximum value 6000 (60 seconds)
- Default value 500 (5 seconds)
… | scalar | Integer32 | .1.3.6.1.4.1.3715.99.1.3.11 |
| controlBusMasterAdminState optional This object tells whether the element is configured as
a bus master or not. Only relevant for bus master type
of elements. Others return no(2). | scalar | Enumeration | .1.3.6.1.4.1.3715.99.1.3.2 |
| controlAlarmDetection mandatory This variable is used to disable or enable the element
alarm checking. When disabled(1), the element
will not check any alarms (or send traps).
Default value is enabled(2).
… | scalar | Enumeration | .1.3.6.1.4.1.3715.99.1.3.3 |
| controlMaxNumberTrapReceivers mandatory Number of entries in the elementTrapReceiverTable.
At least one trap entry must be supported. | scalar | Integer32 | .1.3.6.1.4.1.3715.99.1.3.4 |
| controlTrapSending optional Enables/disables trap sending.
1 = traps enabled
2 = traps disabled | scalar | Enumeration | .1.3.6.1.4.1.3715.99.1.3.6 |
| controlTrapInterval optional The minimum interval between traps.
- Unit 10 milliseconds
- Minimum value 0 (send as fast as possible)
- Maximum value 1000 (10 seconds)
- Default value is 100 (1 second) | scalar | Integer32 | .1.3.6.1.4.1.3715.99.1.3.7 |
| controlTrapLifeTime optional The maximum time a trap stays in the trap queue waiting
for sending.
- Unit 1 second.
- Minimum value 10
- Maximum value 300
- Default value 60 | scalar | Integer32 | .1.3.6.1.4.1.3715.99.1.3.8 |
| controlAlarmOnDelay optional The minimum time an object's alarm/warning condition must
exist before it is recorded as an alarm/warning. Common
to all alarms/warnings
- Unit 10 ms
- Minimum value 10 (100 ms)
-… | scalar | Integer32 | .1.3.6.1.4.1.3715.99.1.3.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| controlTrapReceiverEntry optional | row | - | .1.3.6.1.4.1.3715.99.1.3.5.1 |