controlReset
TELESTE-COMMON-MIB ·
.1.3.6.1.4.1.3715.99.2.3.1.1.3
Object
column
optional
r/w
Enumeration
On write requests this object commands the module to
reset itself.
If softReset(3) or hardReset(2) can not be performed,
then BAD VALUE error is returned.
On read requests value noReset(1) is returned.
Context
- MIB
- TELESTE-COMMON-MIB
- OID
.1.3.6.1.4.1.3715.99.2.3.1.1.3- Type
- column
- Access
- readwrite
- Status
- optional
- Parent
- moduleControlEntry
- Table
- moduleControlTable
- Siblings
- 9
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | noReset |
2 | hardReset |
3 | softReset |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| controlLedUsage optional A variable to instruct how device LED's behave when
the lid is closed. | column | Enumeration | .1.3.6.1.4.1.3715.99.2.3.1.1.1 |
| controlInternalAppAccess optional This object defines whether the internal controller application
is able to access the module parameters. This corresponds
to the BXX module setting 'Allow Functions'.
1 = allow in… | column | Enumeration | .1.3.6.1.4.1.3715.99.2.3.1.1.10 |
| controlLocalAccess optional This object defines whether the local user interface
(buttons, knobs etc.) is enabled or disabled. Values:
1 = disabled, local UI is locked
2 = enabled, local UI is active
For mod… | column | Enumeration | .1.3.6.1.4.1.3715.99.2.3.1.1.11 |
| controlMarkState optional A variable to instruct the device to start and stop
showing mark (blinking module LED).
On read requests returns the current mark state. | column | Enumeration | .1.3.6.1.4.1.3715.99.2.3.1.1.2 |
| controlTempLimitHiHi optional Module temperature HiHi (high alarm) limit in 0.1 degC. | column | Integer32 | .1.3.6.1.4.1.3715.99.2.3.1.1.4 |
| controlTempLimitHi optional Module temperature Hi (high warning) limit in 0.1 degC. | column | Integer32 | .1.3.6.1.4.1.3715.99.2.3.1.1.5 |
| controlTempLimitLo optional Module temperature Lo (low warning) limit in 0.1 degC. | column | Integer32 | .1.3.6.1.4.1.3715.99.2.3.1.1.7 |
| controlTempLimitLoLo optional Module temperature LoLo (low alarm) limit in 0.1 degC. | column | Integer32 | .1.3.6.1.4.1.3715.99.2.3.1.1.8 |
| controlTempDeadBand optional Module temperature alarm/warning deadband in 0.1 degC. Common
to all limit values (LoLo, Lo, Hi, HiHi). The deadband defines
the difference between the 'ON' limit and the 'OFF' li… | column | Integer32 | .1.3.6.1.4.1.3715.99.2.3.1.1.9 |