controlLedUsage
TELESTE-COMMON-MIB ·
.1.3.6.1.4.1.3715.99.2.3.1.1.1
Object
column
optional
r/w
Enumeration
A variable to instruct how device LED's behave when the lid is closed.
Context
- MIB
- TELESTE-COMMON-MIB
- OID
.1.3.6.1.4.1.3715.99.2.3.1.1.1- Type
- column
- Access
- readwrite
- Status
- optional
- Parent
- moduleControlEntry
- Table
- moduleControlTable
- Siblings
- 9
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | notSupported |
2 | alwaysOn |
3 | offWhenLidClosed |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| controlInternalAppAccess optional This object defines whether the internal controller application
is able to access the module parameters. This corresponds
to the BXX module setting 'Allow Functions'.
1 = allow in… | column | Enumeration | .1.3.6.1.4.1.3715.99.2.3.1.1.10 |
| controlLocalAccess optional This object defines whether the local user interface
(buttons, knobs etc.) is enabled or disabled. Values:
1 = disabled, local UI is locked
2 = enabled, local UI is active
For mod… | column | Enumeration | .1.3.6.1.4.1.3715.99.2.3.1.1.11 |
| controlMarkState optional A variable to instruct the device to start and stop
showing mark (blinking module LED).
On read requests returns the current mark state. | column | Enumeration | .1.3.6.1.4.1.3715.99.2.3.1.1.2 |
| controlReset optional On write requests this object commands the module to
reset itself.
If softReset(3) or hardReset(2) can not be performed,
then BAD VALUE error is returned.
… | column | Enumeration | .1.3.6.1.4.1.3715.99.2.3.1.1.3 |
| controlTempLimitHiHi optional Module temperature HiHi (high alarm) limit in 0.1 degC. | column | Integer32 | .1.3.6.1.4.1.3715.99.2.3.1.1.4 |
| controlTempLimitHi optional Module temperature Hi (high warning) limit in 0.1 degC. | column | Integer32 | .1.3.6.1.4.1.3715.99.2.3.1.1.5 |
| controlTempLimitLo optional Module temperature Lo (low warning) limit in 0.1 degC. | column | Integer32 | .1.3.6.1.4.1.3715.99.2.3.1.1.7 |
| controlTempLimitLoLo optional Module temperature LoLo (low alarm) limit in 0.1 degC. | column | Integer32 | .1.3.6.1.4.1.3715.99.2.3.1.1.8 |
| controlTempDeadBand optional Module temperature alarm/warning deadband in 0.1 degC. Common
to all limit values (LoLo, Lo, Hi, HiHi). The deadband defines
the difference between the 'ON' limit and the 'OFF' li… | column | Integer32 | .1.3.6.1.4.1.3715.99.2.3.1.1.9 |