fanState
StorageManagement-MIB ·
.1.3.6.1.4.1.674.10893.1.20.130.7.1.4
Object
column
mandatory
Enumeration
The current condition of the fan. Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 6: Degraded 21: Missing
Context
- MIB
- StorageManagement-MIB
- OID
.1.3.6.1.4.1.674.10893.1.20.130.7.1.4- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- fanEntry
- Table
- fanTable
- Siblings
- 16
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | ready |
2 | failed |
6 | degraded |
11 | removed |
21 | missing |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| fanNumber mandatory Instance number of this fan entry. | column | Integer32 | .1.3.6.1.4.1.674.10893.1.20.130.7.1.1 |
| fanProbeMaxCritical obsolete This entry is obsolete. This setting is not supported
by fans managed under Storage Management. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10893.1.20.130.7.1.10 |
| fanProbeCurrValue mandatory The current speed of the fan. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10893.1.20.130.7.1.11 |
| fan1PartNumber mandatory The part number of the fan in the enclosure. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10893.1.20.130.7.1.12 |
| fan2PartNumber obsolete This entry is obsolete. This setting is not supported
by fans managed under Storage Management. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10893.1.20.130.7.1.13 |
| fanRollUpStatus mandatory Severity of the fan state.
This is the combined status of the fan and its components.
Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable | column | DellStatus | .1.3.6.1.4.1.674.10893.1.20.130.7.1.14 |
| fanComponentStatus mandatory The status of the fan itself without the
propagation of any contained component status.
Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable | column | DellStatus | .1.3.6.1.4.1.674.10893.1.20.130.7.1.15 |
| fanNexusID mandatory Durable unique ID for this fan. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10893.1.20.130.7.1.16 |
| fanRevision mandatory The revision number of the fan in the enclosure. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10893.1.20.130.7.1.17 |
| fanName mandatory The fan's name as represented in Storage Management. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10893.1.20.130.7.1.2 |
| fanVendor mandatory The fan's (re)seller's name. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10893.1.20.130.7.1.3 |
| fanSeverity obsolete This entry is obsolete for Storage Management.
It was replaced with RollUpStatus and ComponentStatus for each device. | column | Enumeration | .1.3.6.1.4.1.674.10893.1.20.130.7.1.5 |
| fanProbeUnit obsolete This entry is obsolete for Storage Management. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10893.1.20.130.7.1.6 |
| fanProbeMinWarning obsolete This entry is obsolete. This setting is not supported
by fans managed under Storage Management. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10893.1.20.130.7.1.7 |
| fanProbeMinCritical obsolete This entry is obsolete. This setting is not supported
by fans managed under Storage Management. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10893.1.20.130.7.1.8 |
| fanProbeMaxWarning obsolete This entry is obsolete. This setting is not supported
by fans managed under Storage Management. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10893.1.20.130.7.1.9 |