st4InputCordEventConfigEntry
Sentry4-MIB ·
.1.3.6.1.4.1.1718.4.1.3.4.1
Object
row
Event configuration objects for a particular input cord.
Context
- MIB
- Sentry4-MIB
- OID
.1.3.6.1.4.1.1718.4.1.3.4.1- Type
- row
- Status
- current
- Parent
- st4InputCordEventConfigTable
- Table
- st4InputCordEventConfigTable
- Children
- 13
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| st4InputCordNotifications The notification methods enabled for input cord events. | column | EventNotificationMethods | .1.3.6.1.4.1.1718.4.1.3.4.1.1 |
| st4InputCordPowerFactorLowAlarm The power factor low alarm threshold of the input cord in
hundredths. | column | hundredths Integer32 | .1.3.6.1.4.1.1718.4.1.3.4.1.10 |
| st4InputCordPowerFactorLowWarning The power factor low warning threshold of the input cord in
hundredths. | column | hundredths Integer32 | .1.3.6.1.4.1.1718.4.1.3.4.1.11 |
| st4InputCordOutOfBalanceHighWarning The 3 phase out-of-balance high warning threshold of the input
cord in percent. | column | percent Integer32 | .1.3.6.1.4.1.1718.4.1.3.4.1.12 |
| st4InputCordOutOfBalanceHighAlarm The 3 phase out-of-balance high alarm threshold of the input cord
in percent. | column | percent Integer32 | .1.3.6.1.4.1.1718.4.1.3.4.1.13 |
| st4InputCordActivePowerLowAlarm The active power low alarm threshold of the input cord in Watts. | column | Watts Integer32 | .1.3.6.1.4.1.1718.4.1.3.4.1.2 |
| st4InputCordActivePowerLowWarning The active power low warning threshold of the input cord in
Watts. | column | Watts Integer32 | .1.3.6.1.4.1.1718.4.1.3.4.1.3 |
| st4InputCordActivePowerHighWarning The active power high warning threshold of the input cord in
Watts. | column | Watts Integer32 | .1.3.6.1.4.1.1718.4.1.3.4.1.4 |
| st4InputCordActivePowerHighAlarm The active power high alarm threshold of the input cord in Watts. | column | Watts Integer32 | .1.3.6.1.4.1.1718.4.1.3.4.1.5 |
| st4InputCordApparentPowerLowAlarm The apparent power low alarm threshold of the input cord in
Volt-Amps. | column | Volt-Amps Integer32 | .1.3.6.1.4.1.1718.4.1.3.4.1.6 |
| st4InputCordApparentPowerLowWarning The apparent power low warning threshold of the input cord in
Volt-Amps. | column | Volt-Amps Integer32 | .1.3.6.1.4.1.1718.4.1.3.4.1.7 |
| st4InputCordApparentPowerHighWarning The apparent power high warning threshold of the input cord in
Volt-Amps. | column | Volt-Amps Integer32 | .1.3.6.1.4.1.1718.4.1.3.4.1.8 |
| st4InputCordApparentPowerHighAlarm The apparent power high alarm threshold of the input cord in
Volt-Amps. | column | Volt-Amps Integer32 | .1.3.6.1.4.1.1718.4.1.3.4.1.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| st4UnitIndex Unit index. A=1, B=2, C=3, D=4, E=5, F=6. | column | Integer32 | .1.3.6.1.4.1.1718.4.1.2.2.1.1 |
| st4InputCordIndex Input cord index. A=1, B=2, C=3, D=4. | column | Integer32 | .1.3.6.1.4.1.1718.4.1.3.2.1.1 |