tempHumidSensorTempValue
Sentry3-MIB ·
.1.3.6.1.4.1.1718.3.2.5.1.6
Object
column
tenth degrees Integer32
The temperature measured by the sensor. A non-negative value indicates the measured temperature in tenths of degrees, using the scale selected by tempHumidSensorTempScale. If the agent does not support the tempHumidSensorTempScale object, then the temperature scale used is Celsius. A negative value indicates that a temperature value was not able to be measured.
Context
- MIB
- Sentry3-MIB
- OID
.1.3.6.1.4.1.1718.3.2.5.1.6- Type
- column
- Access
- readonly
- Status
- current
- Units
- tenth degrees
- Parent
- tempHumidSensorEntry
- Table
- tempHumidSensorTable
- Siblings
- 14
Syntax
tenth degrees Integer32
Values & Constraints
Object Constraints
range: -1-2540
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tempHumidSensorIndex Index for the temperature/humidity sensor table. | column | Integer32 | .1.3.6.1.4.1.1718.3.2.5.1.1 |
| tempHumidSensorHumidValue The humidity measured by the sensor. A non-negative value
indicates the measured humidity in percentage relative
humidity. A negative value indicates that a humidity value
was n… | column | percentage relative humidity Integer32 | .1.3.6.1.4.1.1718.3.2.5.1.10 |
| tempHumidSensorHumidLowThresh The humidity low threshold value of the sensor in percentage
relative humidity. | column | percentage relative humidity Integer32 | .1.3.6.1.4.1.1718.3.2.5.1.11 |
| tempHumidSensorHumidHighThresh The humidity low threshold value of the sensor in percentage
relative humidity. | column | percentage relative humidity Integer32 | .1.3.6.1.4.1.1718.3.2.5.1.12 |
| tempHumidSensorTempScale The scale used for temperature values. This is a global
setting for all temperature values in the system. If the
agent does not support this object, then the temperature
scale u… | column | Enumeration | .1.3.6.1.4.1.1718.3.2.5.1.13 |
| tempHumidSensorTempRecDelta The temperature recovery delta (hysteresis) value of the
sensor in degrees, using the scale selected by
tempHumidSensorTempScale. | column | degrees Integer32 | .1.3.6.1.4.1.1718.3.2.5.1.14 |
| tempHumidSensorHumidRecDelta The humidity recovery delta (hysteresis) value of the
sensor in percentage relative humidity. | column | percentage relative humidity Integer32 | .1.3.6.1.4.1.1718.3.2.5.1.15 |
| tempHumidSensorID The ID of the temperature/humidity sensor. | column | OctetString | .1.3.6.1.4.1.1718.3.2.5.1.2 |
| tempHumidSensorName The name of the temperature/humidity sensor. | column | OctetString | .1.3.6.1.4.1.1718.3.2.5.1.3 |
| tempHumidSensorStatus The operational status of the temperature/humidity sensor. | column | Enumeration | .1.3.6.1.4.1.1718.3.2.5.1.4 |
| tempHumidSensorTempStatus The status of the temperature sensor. | column | Enumeration | .1.3.6.1.4.1.1718.3.2.5.1.5 |
| tempHumidSensorTempLowThresh The temperature low threshold value of the sensor in degrees,
using the scale selected by tempHumidSensorTempScale. If the
agent does not support the tempHumidSensorTempScale obj… | column | degrees Integer32 | .1.3.6.1.4.1.1718.3.2.5.1.7 |
| tempHumidSensorTempHighThresh The temperature high threshold value of the sensor in degrees,
using the scale selected by tempHumidSensorTempScale. If the
agent does not support the tempHumidSensorTempScale ob… | column | degrees Integer32 | .1.3.6.1.4.1.1718.3.2.5.1.8 |
| tempHumidSensorHumidStatus The status of the humidity sensor. | column | Enumeration | .1.3.6.1.4.1.1718.3.2.5.1.9 |