rAlarmStartupAlarm

SWITCH-RMON-MIB · .1.3.6.1.4.1.8886.6.1.22.3.1.1.6

Object

column mandatory r/w Enumeration
The alarm that may be sent when this entry is first
set to valid.  If the first sample after this entry
becomes valid is greater than or equal to the
risingThreshold and alarmStartupAlarm is equal to
risingAlarm(1) or risingOrFallingAlarm(3), then a
single rising alarm will be generated.  If the first
sample after this entry becomes valid is less than
or equal to the fallingThreshold and
alarmStartupAlarm is equal to fallingAlarm(2) or
risingOrFallingAlarm(3), then a single falling alarm
will be generated.
              
This object may not be modified if the associated
alarmStatus object is equal to valid(1).

Context

MIB
SWITCH-RMON-MIB
OID
.1.3.6.1.4.1.8886.6.1.22.3.1.1.6
Type
column
Access
readwrite
Status
mandatory
Parent
rAlarmEntry
Table
rAlarmTable
Siblings
11

Syntax

Enumeration

Values & Constraints

Enumerated Values
1risingAlarm
2fallingAlarm
3risingOrFallingAlarm

Related Objects

Sibling Objects