rAlarmFallingThreshold

SWITCH-RMON-MIB · .1.3.6.1.4.1.8886.6.1.22.3.1.1.8

Object

column mandatory r/w Integer32
A threshold for the sampled statistic.  When the
current sampled value is less than or equal to this
threshold, and the value at the last sampling
interval was greater than this threshold, a single
event will be generated.  A single event will also
be generated if the first sample after this entry
becomes valid is less than or equal to this
threshold and the associated alarmStartupAlarm is
equal to fallingAlarm(2) or risingOrFallingAlarm(3).
              
After a falling event is generated, another such event
will not be generated until the sampled value
rises above this threshold and reaches the
alarmRisingThreshold.
              
This object may not be modified if the associated
alarmStatus object is equal to valid(1).

Context

MIB
SWITCH-RMON-MIB
OID
.1.3.6.1.4.1.8886.6.1.22.3.1.1.8
Type
column
Access
readwrite
Status
mandatory
Parent
rAlarmEntry
Table
rAlarmTable
Siblings
11

Syntax

Integer32
Source
COPS-PR-SPPIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647

Related Objects

Sibling Objects