sub10EthernetAlarm
SUB10SYSTEMS-MIB ·
.1.3.6.1.4.1.39003.0.2
Object
notification
A measured object relating the Ethernet subsystem has been raised or cleared according to the configured thresholds. For alarm configuration see sub10UnitMgmtAlarmTable.
Context
- MIB
- SUB10SYSTEMS-MIB
- OID
.1.3.6.1.4.1.39003.0.2- Type
- notification
- Status
- current
- Parent
- sub10Notifications
- Siblings
- 2
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| sub10UnitAlarm A measured object relating the Unit subsystem has been raised or cleared according
to the configured thresholds. For alarm configuration see sub10UnitMgmtAlarmTable. | notification | - | .1.3.6.1.4.1.39003.0.1 |
| sub10RadioAlarm A measured object relating the Radio subsystem has been raised or cleared according
to the configured thresholds. For alarm configuration see sub10UnitMgmtAlarmTable. | notification | - | .1.3.6.1.4.1.39003.0.3 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| sub10UnitMgmtAlarmName The alarm name. This is a short descriptive name for the alarm.
Alarm names can be duplicated across entries in order to define
the same alarm to be raised and cleared according t… | column | Sub10AlarmName | .1.3.6.1.4.1.39003.3.2.6.1.1.3 |
| sub10UnitLclAlarmState Internal object to indicate if this alarm is currently in the
raised or cleared state. | column | Sub10AlarmState | .1.3.6.1.4.1.39003.3.1.1.15.1.2 |
| sub10UnitMgmtAlarmSeverity The alarm severity. This is added to each alarm as a parameter. | column | Sub10AlarmSeverity | .1.3.6.1.4.1.39003.3.2.6.1.1.4 |
| sub10UnitMgmtAlarmMeasObject The measured object. This is the object name of the
object in the MIB with which the alarm is associated and
which the configured thresholds are compared with when
deriving the st… | column | Sub10MeasuredObject | .1.3.6.1.4.1.39003.3.2.6.1.1.5 |
| sub10UnitMgmtAlarmMeasObjectVal The value of sub10UnitMgmtAlarmMeasObject formatted as a displayString which when
measured by the alarm subsystem caused an alarm to be either raised or cleared.
This is therefore… | column | OctetString | .1.3.6.1.4.1.39003.3.2.6.1.1.17 |
| sub10UnitMgmtAlarmRaiseOper Type of operation which determines when an alarm
is to be raised.
Definition of each type is as follows:
lt - Measured objects value is less than rai… | column | Sub10AlarmOperation | .1.3.6.1.4.1.39003.3.2.6.1.1.7 |
| sub10UnitMgmtAlarmRaiseThresh The threshold value which the measured object's value
crosses causes the alarm to be raised. The behaviour of a
measured value and alarm threshold comparison is
defined by the obj… | column | OctetString | .1.3.6.1.4.1.39003.3.2.6.1.1.8 |
| sub10UnitMgmtAlarmClearOper Type of operation which determines when an alarm
is to be cleared.
Definition of each type is as follows:
lt - Measured objects value is less than cl… | column | Sub10AlarmOperation | .1.3.6.1.4.1.39003.3.2.6.1.1.9 |
| sub10UnitMgmtAlarmClearThresh The threshold value which the measured object's value
crosses causes the alarm to be cleared. The behaviour of a
measured value and alarm threshold comparison is
defined by the ob… | column | OctetString | .1.3.6.1.4.1.39003.3.2.6.1.1.10 |