loadMonitorErrorTrapRepeatCounter
SP2-MIB ·
.1.3.6.1.4.1.12148.10.13.12.4.3
Object
scalar
SNMPv2-SMIInteger32
The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off.
Context
- MIB
- SP2-MIB
- OID
.1.3.6.1.4.1.12148.10.13.12.4.3- Type
- scalar
- Access
- notifyonly
- Status
- current
- Parent
- loadMonitorError
- Siblings
- 6
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| loadMonitorErrorStatus This status value shows if the number of failed load monitors is higher than the defined alarm level. | scalar | Enumeration | .1.3.6.1.4.1.12148.10.13.12.4.1 |
| loadMonitorErrorDescription A textual description of the load monitor error monitor. This is stored in the system controller
and can be changed by the user. | scalar | OctetString | .1.3.6.1.4.1.12148.10.13.12.4.2 |
| loadMonitorErrorAlarmEnable This value once enabled, the alarm condition of the monitor will be reported. | scalar | Enumeration | .1.3.6.1.4.1.12148.10.13.12.4.4 |
| loadMonitorErrorValue The detected number of failed load monitors. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.12148.10.13.12.4.5 |
| loadMonitorErrorMajorAlarmLevel The major alarm limit | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.12148.10.13.12.4.6 |
| loadMonitorErrorMinorAlarmLevel The minor alarm limit | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.12148.10.13.12.4.7 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| EATON-EPDU-PU-SW-MIBinfoItemIdx Numerical index of the item that caused the notification. For example, if the notification
was related to the state of outlet 5, this value will be 5 no matter what the customize… | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20677.2.10.1 |
| EATON-EPDU-PU-SW-MIBinfoItemName Textual name of the item that caused the notification. For example, if an outlet
state change caused the notification, this will be the customized name of the outlet.
If a voltag… | scalar | OctetString | .1.3.6.1.4.1.20677.2.10.2 |
| EATON-EPDU-PU-SW-MIBinfoThresholdState The new state of a measurement that has upper and lower thresholds. | scalar | Enumeration | .1.3.6.1.4.1.20677.2.10.4 |
| EATON-EPDU-PU-SW-MIBinfoThresholdValue The threshold which has been crossed. | scalar | Integer32 | .1.3.6.1.4.1.20677.2.10.5 |
| EATON-EPDU-PU-SW-MIBinfoMeasuredValue The actual measured value. | scalar | Integer32 | .1.3.6.1.4.1.20677.2.10.6 |
| EATON-EPDU-PU-SW-MIBfahrenheitOrCelsius Units for temperature readings. | scalar | Enumeration | .1.3.6.1.4.1.20677.2.1.9 |