loadMonitorErrorAlarmEnable
SP2-MIB ·
.1.3.6.1.4.1.12148.10.13.12.4.4
Object
scalar
r/w
Enumeration
This value once enabled, the alarm condition of the monitor will be reported.
Context
- MIB
- SP2-MIB
- OID
.1.3.6.1.4.1.12148.10.13.12.4.4- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- loadMonitorError
- Siblings
- 6
Syntax
Enumeration
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| loadMonitorErrorStatus This status value shows if the number of failed load monitors is higher than the defined alarm level. | scalar | Enumeration | .1.3.6.1.4.1.12148.10.13.12.4.1 |
| loadMonitorErrorDescription A textual description of the load monitor error monitor. This is stored in the system controller
and can be changed by the user. | scalar | OctetString | .1.3.6.1.4.1.12148.10.13.12.4.2 |
| loadMonitorErrorTrapRepeatCounter The number of consecutive times this alam condition has been transmitted in a trap.
When trap repetition is enabled, this counter increments every time this trap is repeated.
T… | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.12148.10.13.12.4.3 |
| loadMonitorErrorValue The detected number of failed load monitors. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.12148.10.13.12.4.5 |
| loadMonitorErrorMajorAlarmLevel The major alarm limit | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.12148.10.13.12.4.6 |
| loadMonitorErrorMinorAlarmLevel The minor alarm limit | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.12148.10.13.12.4.7 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| EATON-EPDU-PU-SW-MIBinfoItemIdx Numerical index of the item that caused the notification. For example, if the notification
was related to the state of outlet 5, this value will be 5 no matter what the customize… | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20677.2.10.1 |
| EATON-EPDU-PU-SW-MIBinfoItemName Textual name of the item that caused the notification. For example, if an outlet
state change caused the notification, this will be the customized name of the outlet.
If a voltag… | scalar | OctetString | .1.3.6.1.4.1.20677.2.10.2 |
| EATON-EPDU-PU-SW-MIBinfoThresholdState The new state of a measurement that has upper and lower thresholds. | scalar | Enumeration | .1.3.6.1.4.1.20677.2.10.4 |
| EATON-EPDU-PU-SW-MIBinfoThresholdValue The threshold which has been crossed. | scalar | Integer32 | .1.3.6.1.4.1.20677.2.10.5 |
| EATON-EPDU-PU-SW-MIBinfoMeasuredValue The actual measured value. | scalar | Integer32 | .1.3.6.1.4.1.20677.2.10.6 |