invertersTemperature
SP2-MIB ·
.1.3.6.1.4.1.12148.10.16.3
Object
node
No description available.
Syntax
No syntax metadata recorded.
Values & Constraints
Enumerated Values
1 | disabled |
2 | sendToLog |
3 | sendAlert |
4 | sendtoLogAndAlert |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| invertersStatus The overall status of inverter subsystem. | scalar | Enumeration | .1.3.6.1.4.1.12148.10.16.1 |
| invertersAcFrequencyDeviation | node | - | .1.3.6.1.4.1.12148.10.16.10 |
| invertersAcFrequency | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.12148.10.16.11 |
| invertersError | node | - | .1.3.6.1.4.1.12148.10.16.2 |
| invertersAcCurrent1 | node | - | .1.3.6.1.4.1.12148.10.16.4 |
| invertersAcCurrent2 | node | - | .1.3.6.1.4.1.12148.10.16.5 |
| invertersAcCurrent3 | node | - | .1.3.6.1.4.1.12148.10.16.6 |
| invertersAcVoltage1 | node | - | .1.3.6.1.4.1.12148.10.16.7 |
| invertersAcVoltage2 | node | - | .1.3.6.1.4.1.12148.10.16.8 |
| invertersAcVoltage3 | node | - | .1.3.6.1.4.1.12148.10.16.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| invertersTemperatureStatus The state of the rectifier temperature can be either one of the defined enumerated values | scalar | Enumeration | .1.3.6.1.4.1.12148.10.16.3.1 |
| invertersTemperatureDescription A textual description of the rectifier temperature monitor. This is stored in the system controller
and can be changed by the user. | scalar | OctetString | .1.3.6.1.4.1.12148.10.16.3.2 |
| invertersTemperatureTrapRepeatCounter The number of consecutive times this alamcondition has been transmitted in a trap.
When trap repetition is enabled, this counter increments every time this trap is repeated.
Th… | scalar | SNMPv2-SMICounter32 | .1.3.6.1.4.1.12148.10.16.3.3 |
| invertersTemperatureAlarmEnable This value once enabled, the alarm condition of the monitor will be reported. | scalar | Enumeration | .1.3.6.1.4.1.12148.10.16.3.4 |
| invertersTemperatureValue The highest value of the rectifier temperature measurements.
Depending on the global setting in the Control unit, this value will be presented in Celsius
or Fahrenheit. | scalar | Integer32 | .1.3.6.1.4.1.12148.10.16.3.5 |
| invertersTemperatureMajorHighLevel The major high alarm limit | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.12148.10.16.3.6 |
| invertersTemperatureMinorHighLevel The minor high alarm limit | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.12148.10.16.3.7 |
| invertersTemperatureMinorLowLevel The minor low alarm limit | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.12148.10.16.3.8 |
| invertersTemperatureMajorLowLevel The major low alarm limit | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.12148.10.16.3.9 |