generatorFailure
SP2-MIB ·
.1.3.6.1.4.1.12148.10.4.27
Object
node
No description available.
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| generatorStatus The overall status of generator subsystem. | scalar | Enumeration | .1.3.6.1.4.1.12148.10.4.1 |
| generatorCurrentLimitControlledStopEnable Enables the generator to stop when the charge current drops below generatorCurrentLimitControlledStopValue. | scalar | Enumeration | .1.3.6.1.4.1.12148.10.4.10 |
| generatorCurrentLimitControlledStopValue Generator stops when the charge current drop drops below this level. | scalar | Integer32 | .1.3.6.1.4.1.12148.10.4.11 |
| generatorVoltageControlledStartEnable Enable/disable voltage controlled generator activation. | scalar | Enumeration | .1.3.6.1.4.1.12148.10.4.12 |
| generatorVoltageControlStartVoltage The voltage limit to start generator. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.12148.10.4.13 |
| generatorVoltageControlStopAfter A time delay for stopping generator when generator is activated by voltage. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.12148.10.4.14 |
| generatorDailyRunEnable Enable/disable generator daily run function. | scalar | Enumeration | .1.3.6.1.4.1.12148.10.4.15 |
| generatorDailyRunSetupTable This table contains configurations of generator daily run. | table | - | .1.3.6.1.4.1.12148.10.4.16 |
| generatorMonthlyRunEnable Enable/disable generator monthly run function. | scalar | Enumeration | .1.3.6.1.4.1.12148.10.4.17 |
| generatorMonthlyRunStartTime Generator monthly run starting time. | scalar | Integer32 | .1.3.6.1.4.1.12148.10.4.18 |
| generatorMonthlyRunStartDayinMonth1 Generator monthly run starting day #1. | scalar | Integer32 | .1.3.6.1.4.1.12148.10.4.19 |
| generatorFailStatus The status of generator failure monitor. | scalar | Enumeration | .1.3.6.1.4.1.12148.10.4.2 |
| generatorMonthlyRunStartDayinMonth2 Generator monthly run starting day #2. | scalar | Integer32 | .1.3.6.1.4.1.12148.10.4.20 |
| generatorTankNumberOfTanks Number of fuel tanks. | scalar | Integer32 | .1.3.6.1.4.1.12148.10.4.21 |
| generatorTankTable This table contains information about generator fuel tanks. | table | - | .1.3.6.1.4.1.12148.10.4.22 |
| generatorEnergyLog | node | - | .1.3.6.1.4.1.12148.10.4.23 |
| generatorRunHoursLog | node | - | .1.3.6.1.4.1.12148.10.4.24 |
| generatorFuelConsumptionLog | node | - | .1.3.6.1.4.1.12148.10.4.25 |
| gseGenerator | node | - | .1.3.6.1.4.1.12148.10.4.26 |
| generatorActivation Indicate if the generator run output signal is activated. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.12148.10.4.3 |
| generatorDischargeValue This is the present discharge value in percentage of total capacity. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.12148.10.4.4 |
| generatorMainsDelay Elapsing time of mains failure. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.12148.10.4.5 |
| generatorChargeTime Elapsing time of charging with generator running. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.12148.10.4.6 |
| generatorCapacityControlledStartStopEnable Battery charge/discharge level control of starting and stopping of generator | scalar | Enumeration | .1.3.6.1.4.1.12148.10.4.7 |
| generatorCapacityStartOnDischargeLimit When the generatorCapacityControlled is enabled, the generator is started
when the remaining battery capacity drops below this limit in percentage of the total capacity. | scalar | Integer32 | .1.3.6.1.4.1.12148.10.4.8 |
| generatorCapacityStopOnChargeLimit When the generatorCapacityControlled is enabled, the generator is stopped
when the remaining battery capacity is greater than this limit in percentage of the total capacity. | scalar | Integer32 | .1.3.6.1.4.1.12148.10.4.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| generatorFailureStatus This status value shows if the number of failed phases is higher than the defined alarm level. | scalar | Enumeration | .1.3.6.1.4.1.12148.10.4.27.1 |
| generatorFailureDescription A textual description of the generator failure monitor. This is stored in the system controller
and can be changed by the user. | scalar | OctetString | .1.3.6.1.4.1.12148.10.4.27.2 |
| generatorFailureTrapRepeatCounter The number of consecutive times this alam condition has been transmitted in a trap.
When trap repetition is enabled, this counter increments every time this trap is repeated.
T… | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.12148.10.4.27.3 |
| generatorFailureAlarmEnable This value once enabled, the alarm condition of the monitor will be reported. | scalar | Enumeration | .1.3.6.1.4.1.12148.10.4.27.4 |
| generatorFailureValue The value of the monitor. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.12148.10.4.27.5 |