controlSystemNumberOfGenericModbusData
SP2-MIB ·
.1.3.6.1.4.1.12148.10.13.23
Object
scalar
Integer32
Number of genaric Modbus data configured in system
Context
- MIB
- SP2-MIB
- OID
.1.3.6.1.4.1.12148.10.13.23- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- controlSystem
- Siblings
- 30
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-50
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| controlSystemStatus The overall status of control system subsystem | scalar | Enumeration | .1.3.6.1.4.1.12148.10.13.1 |
| flexiMonitors | node | - | .1.3.6.1.4.1.12148.10.13.10 |
| mainControlUnits | node | - | .1.3.6.1.4.1.12148.10.13.11 |
| controlSystemSummary | node | - | .1.3.6.1.4.1.12148.10.13.12 |
| ambientTemperature | node | - | .1.3.6.1.4.1.12148.10.13.13 |
| deltaTemperature | node | - | .1.3.6.1.4.1.12148.10.13.14 |
| userSuspended | node | - | .1.3.6.1.4.1.12148.10.13.15 |
| controlSystemSaveEnergyLog Save energy logs to FTP server. | scalar | Enumeration | .1.3.6.1.4.1.12148.10.13.16 |
| controlSystemSaveDataLog Save data logs to FTP server. | scalar | Enumeration | .1.3.6.1.4.1.12148.10.13.17 |
| controlSystemNTPServerIP | scalar | OctetString | .1.3.6.1.4.1.12148.10.13.18 |
| controlSystemReboot Reboot main controller (Smartpack 2, Smartpack S, Compack, Smartpack 2 TOUCH) | scalar | Enumeration | .1.3.6.1.4.1.12148.10.13.19 |
| controlSystemClock This is the system time. | scalar | OctetString | .1.3.6.1.4.1.12148.10.13.2 |
| controlSystemSaveEventLog Save event logs to FTP server. | scalar | Enumeration | .1.3.6.1.4.1.12148.10.13.20 |
| controlSystemSaveAccountLog Save account logs to FTP server. | scalar | Enumeration | .1.3.6.1.4.1.12148.10.13.21 |
| controlSystemSetCfgFromXmlFiles Set configurations from default1.XML, default2.XML and default3.XML in Default folder | scalar | Enumeration | .1.3.6.1.4.1.12148.10.13.22 |
| controlSystemGenericModbusDataTable | table | - | .1.3.6.1.4.1.12148.10.13.24 |
| demandResponse | node | - | .1.3.6.1.4.1.12148.10.13.25 |
| genericAlarmMonitorTable generic alarm monitors to be used with 3rd-party modbus devices | table | - | .1.3.6.1.4.1.12148.10.13.26 |
| genericLogsTable Generic logs connected to the last ten generic alarm monitors (#91-#100) | table | - | .1.3.6.1.4.1.12148.10.13.27 |
| genericLogDaysTable This table contains daily generic log. | table | - | .1.3.6.1.4.1.12148.10.13.28 |
| genericLogWeeksTable This table contains weekly generic log. | table | - | .1.3.6.1.4.1.12148.10.13.29 |
| controlSystemNumberOfControlUnits Total number of main controllers (SP2 Master, SP2 Basic Ind, SP2 Basic, Compack, Smartpack S, Smartpack) | scalar | Integer32 | .1.3.6.1.4.1.12148.10.13.3 |
| genericLogMonthsTable This table contains monthly generic log. | table | - | .1.3.6.1.4.1.12148.10.13.30 |
| tariffControl | node | - | .1.3.6.1.4.1.12148.10.13.31 |
| snmp | node | - | .1.3.6.1.4.1.12148.10.13.4 |
| controlSystemResetManualAlarms Reset manual alarms and put buzzer into silence. | scalar | Enumeration | .1.3.6.1.4.1.12148.10.13.5 |
| controlSystemResetNumberOfModules If set to '1', the number of modules (rectifier, solar charger, wind charger, control units, etc.)
will be reset, and only those modules communicating are counted. | scalar | Enumeration | .1.3.6.1.4.1.12148.10.13.6 |
| controlSystemIoUnits | node | - | .1.3.6.1.4.1.12148.10.13.7 |
| controlSystemInventory | node | - | .1.3.6.1.4.1.12148.10.13.8 |
| currentMonitors | node | - | .1.3.6.1.4.1.12148.10.13.9 |