upsAlarmRectifierFault
SOCOMECUPS7-MIB ·
.1.3.6.1.4.1.4555.1.1.7.1.6.3.20
Object
scalar
mandatory
Integer32
Rectifier Critical alarm. (A032)
Context
- MIB
- SOCOMECUPS7-MIB
- OID
.1.3.6.1.4.1.4555.1.1.7.1.6.3.20- Type
- scalar
- Access
- readonly
- Status
- mandatory
- Parent
- upsWellKnownAlarms
- Siblings
- 61
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsAlarmImminentStop mandatory UPS in imminent stop. Load will switch off. (A000) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.1 |
| upsAlarmRemoteService mandatory The UPS requests a remote service action. (A013) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.10 |
| upsAlarmGeneralFault mandatory A general fault in the UPS has been detected.
One of UPS alarm is present. (A015) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.11 |
| upsAlarmBatteryCircuitOpen mandatory Battery circuit open. Battery breaker or fuse open. (A016) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.12 |
| upsAlarmBatteryDischarged mandatory The UPS will be unable to sustain the present load
when and if the utility power is lost.
The Battery is discharched. (A017) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.13 |
| upsAlarmLowBattery mandatory The remaining battery run-time is less than or equal
to battery low threshold. (A018) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.14 |
| upsAlarmOnBattery mandatory The UPS is drawing power from the batteries. (A019) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.15 |
| upsAlarmBatteryTemperature mandatory Battery Temperature Alarm. (A020) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.16 |
| upsAlarmBatteryRoom mandatory An external alarm has been detected in the Battery room.
This alarm depends on external sensor: gaz, temperature,
humidity or dry-contact. (A021) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.17 |
| upsAlarmBatteryTest mandatory The battery has been detected as weak during the test. (A022) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.18 |
| upsAlarmBatteryFault mandatory One or more batteries have been determined to require replacement. (A027) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.19 |
| upsAlarmOverload mandatory The output load exceeds the UPS output capacity. (A001) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.2 |
| upsAlarmRectifierAlarm mandatory Rectifier Preventive alarm. (A033) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.21 |
| upsAlarmRecInputBad mandatory rectifier Input power supply is out of tolerance or absent. (A035) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.22 |
| upsAlarmGenSetGeneral mandatory Gen-set general alarm.
coming from external dry-contact. (A036) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.23 |
| upsAlarmBatteryChargerFault mandatory Battery charger Critical Alarm. (A037) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.24 |
| upsAlarmBatteryChargerAlarm mandatory Battery charger Preventive Alarm. (A038) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.25 |
| upsAlarmInverterFault mandatory Inverter Critical alarm. (A040) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.26 |
| upsAlarmInverterAlarm mandatory Inverter preventive alarm. (A041) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.27 |
| upsAlarmBypassFault mandatory Inverter Critical alarm. (A048) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.28 |
| upsAlarmBypassAlarm mandatory Inverter preventive alarm. (A049) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.29 |
| upsAlarmTemperature mandatory UPS temperature is out of tolerance. (A002) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.3 |
| upsAlarmBypInputBad mandatory Bypass Input power supply is out of tolerance or absent. (A050) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.30 |
| upsAlarmPhaseRotationFault mandatory Phase rotation fault. (A051) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.31 |
| upsAlarmFansFailure mandatory Fans failure. (A054) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.32 |
| upsAlarmMaintenanceBypass mandatory Maintenance bypass alarm.
Output breaker and manual bypass breaker closed together. (A056) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.33 |
| upsAlarmUPSPowerOffActive mandatory UPS power off has been activated by external device. (A059) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.34 |
| upsAlarmWrongConfiguration mandatory Configuration data map corrupted, or wrong configuration. (A060) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.35 |
| upsAlarmInternalFailure mandatory Internal failure, or internal communication failure. (A061) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.36 |
| upsAlarmOptionalBoards mandatory Optional boards alarm.
Board not present or wrong configuration (A062) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.37 |
| upsAlarmExternalAlarm1 mandatory External Alarm 1.
Coming from ADC Card: Input set as alarm (A064) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.38 |
| upsAlarmExternalAlarm2 mandatory External Alarm 2.
Coming from ADC Card: Input set as alarm (A065) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.39 |
| upsAlarmTransferLock mandatory Automatic and manual transfer are locked. (A003) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.4 |
| upsAlarmExternalAlarm3 mandatory External Alarm 3.
Coming from ADC Card: Input set as alarm (A066) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.40 |
| upsAlarmExternalAlarm4 mandatory External Alarm 4.
Coming from ADC Card: Input set as alarm (A067) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.41 |
| upsAlarmModule1Alarm mandatory Unit or Module 1 in parallel general alarm. | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.42 |
| upsAlarmModule2Alarm mandatory Unit or Module 2 in parallel general alarm. | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.43 |
| upsAlarmModule3Alarm mandatory Unit or Module 3 in parallel general alarm. | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.44 |
| upsAlarmModule4Alarm mandatory Unit or Module 4 in parallel general alarm. | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.45 |
| upsAlarmModule5Alarm mandatory Unit or Module 5 in parallel general alarm. | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.46 |
| upsAlarmModule6Alarm mandatory Unit or Module 6 in parallel general alarm. | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.47 |
| upsAlarmModule7Alarm mandatory Unit or Module 7 in parallel general alarm. | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.48 |
| upsAlarmModule8Alarm mandatory Unit or Module 8 in parallel general alarm. | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.49 |
| upsAlarmAutoTransferImpossible mandatory Automatic transfer is disabled.
Inverter and bypass sources are not synchronized (A004) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.5 |
| upsAlarmModule9Alarm mandatory Unit or Module 9 in parallel general alarm. | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.50 |
| upsAlarmModule10Alarm mandatory Unit or Module 10 in parallel general alarm. | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.51 |
| upsAlarmModule11Alarm mandatory Unit or Module 11 in parallel general alarm. | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.52 |
| upsAlarmModule12Alarm mandatory Unit or Module 12 in parallel general alarm. | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.53 |
| upsAlarmAutoTestRunning mandatory The UPS has launched the auto-test. (S030) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.54 |
| upsAlarmOnBypass mandatory Load supplied by automatic bypass.
Load not protected. | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.55 |
| upsAlarmUpsOutputOff mandatory The output of the UPS is in the off state.
Load OFF or UPS on standby mode. | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.56 |
| upsAlarmUpsSystemOff mandatory The UPS system is in the off state.
Rectifier and Inverter are off. | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.57 |
| upsAlarmCommunicationLost mandatory The communication with UPS has been lost. | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.58 |
| upsAlarmShutdownPending mandatory The condition to shutdown servers has been detected.
The shutdown delay in underway. | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.59 |
| upsAlarmInsufficientResources mandatory Insufficient resources alarm.
The load cannot by supplied by alternate source (A005) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.6 |
| upsAlarmShutdownRequestt mandatory The shutdown command has been sent to servers agent. | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.60 |
| upsAlarmShutdownImminent mandatory The UPS will turn OFF,
according the standby schedule settings. | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.61 |
| upsAlarmAwaitingPower mandatory The UPS output is in standby,
and the UPS is awaiting the return of input power. | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.62 |
| upsAlarmRedundancyLost mandatory Redundancy lost alarm. (A006) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.7 |
| upsAlarmOutputShortCircuit mandatory An output short-circuit has been detected by UPS. (A007) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.8 |
| upsAlarmMaintenance mandatory The UPS requests a maintenance service check. (A012) | scalar | Integer32 | .1.3.6.1.4.1.4555.1.1.7.1.6.3.9 |