sleAMConfigControlLed
SLE-AM-MIB ·
.1.3.6.1.4.1.6296.101.15.2.2.12
Object
Alarm led configuration. Determinde led operate or not, when alarms occur. off(0): led not operate on(1) : led operate
Context
- MIB
- SLE-AM-MIB
- OID
.1.3.6.1.4.1.6296.101.15.2.2.12- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- sleAMConfigControl
- Siblings
- 11
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| sleAMConfigControlRequest The configuration commands, and user can configure
functions via setting this entry as proper value. | scalar | Enumeration | .1.3.6.1.4.1.6296.101.15.2.2.1 |
| sleAMConfigControlRaiseGuardTime Alarm Raise Soaking time. When any alarm is raised, this attribute
specifies how much time the alarm should be soaked before notifying
to Alarm manager
range:1 ~ 30, (if '0', no s… | scalar | AMAlarmGuardTime | .1.3.6.1.4.1.6296.101.15.2.2.10 |
| sleAMConfigControlClearGuardTime Alarm clear Soaking time. When any alarm is cleared, this attribute
specifies how much time the alarm should be soaked before notifying
to Alarm manager
range:1 ~ 30, (if '0', no … | scalar | AMAlarmGuardTime | .1.3.6.1.4.1.6296.101.15.2.2.11 |
| sleAMConfigControlStatus status of user command. User have to check this
value as .busy. or .idle. before do setRequest. | scalar | SLE-TC-MIBSleControlStatusType | .1.3.6.1.4.1.6296.101.15.2.2.2 |
| sleAMConfigControlTimer the wait-time until setRequest
end. In case of short-time command, this value is 0 | scalar | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.6296.101.15.2.2.3 |
| sleAMConfigControlTimeStamp the time stamp of the last command. (don.t care) | scalar | SNMPv2-SMITimeTicks | .1.3.6.1.4.1.6296.101.15.2.2.4 |
| sleAMConfigControlReqResult Result of the last command. | scalar | SLE-TC-MIBSleControlRequestResultType | .1.3.6.1.4.1.6296.101.15.2.2.5 |
| sleAMConfigControlAlarmClassId Alarm Manager Class ID | scalar | AMAlarmClassId | .1.3.6.1.4.1.6296.101.15.2.2.6 |
| sleAMConfigControlAlarmId Alarm Manager Alarm Index | scalar | AMAlarmId | .1.3.6.1.4.1.6296.101.15.2.2.7 |
| sleAMConfigControlSeverity Alarm Class Severity
critical(1),
major(2),
minor(3),
warning(4),
ignore(5),
default(6) | scalar | AMAlarmSeverity | .1.3.6.1.4.1.6296.101.15.2.2.8 |
| sleAMConfigControlEnableState Alarm Trap State. Based on the trap state,
the alarm will be notified to NMS. If the TRAP STATE is enabled
then the alarm will be notified else wont be notified.
enable (1)