ptpClockRowStatus
SIAE-PTP-MIB ·
.1.3.6.1.4.1.3373.1103.100.4.1.1.14
Object
RowStatus for creating the entries into this table. This object support only destroy and createAndGo values.
Context
- MIB
- SIAE-PTP-MIB
- OID
.1.3.6.1.4.1.3373.1103.100.4.1.1.14- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- ptpClockDataSetEntry
- Table
- ptpClockDataSetTable
- Siblings
- 13
Values & Constraints
Type Values
1 | active |
2 | notInService |
3 | notReady |
4 | createAndGo |
5 | createAndWait |
6 | destroy |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ptpClockDomainIndex This object specifies the domain number used to create logical
group of PTP devices. The Clock Domain is a logical group of
clocks and devices that synchronize with each other usi… | column | ClockDomainType | .1.3.6.1.4.1.3373.1103.100.4.1.1.1 |
| ptpClockPriority1 This value is used by BMC algorithm to select the best master
clock. Lower values take precedence. | column | Integer32 | .1.3.6.1.4.1.3373.1103.100.4.1.1.10 |
| ptpClockPriority2 This value is used by BMC algorithm to select the best master clock.
This is used as a tiebreaker when the BMC failes to order the clock
using ptpClockPriority1, ptpClockClass, p… | column | Integer32 | .1.3.6.1.4.1.3373.1103.100.4.1.1.11 |
| ptpClockSlaveOnly Configuring this value as true will make the clock to behave as slave
clock.
A boundary clock can not be a slave only clock. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.3373.1103.100.4.1.1.12 |
| ptpClockLocalPriority This attribute is used in the alternate BMCA as a tie-breaker in the
dataset comparison algorithm, in the event that all other previous
attributes of the datasets being compared a… | column | Integer32 | .1.3.6.1.4.1.3373.1103.100.4.1.1.13 |
| ptpClockTypeIndex This object specifies the clock type as defined in the
Textual convention description. | column | ClockType | .1.3.6.1.4.1.3373.1103.100.4.1.1.2 |
| ptpClockInstanceIndex This object specifies the instance of the Clock for this clock
type for the given domain. | column | Unsigned32 | .1.3.6.1.4.1.3373.1103.100.4.1.1.3 |
| ptpClockIdentity This is the unique identity of the local clock or management node.
This should be the smptpDomainClockIdentity of the domain indicated
by the ptpDomainNumber. Configuration of thi… | column | OctetString | .1.3.6.1.4.1.3373.1103.100.4.1.1.4 |
| ptpClockTwoStepFlag This value is TRUE if the clock is two step clock, otherwise it is
FALSE. If this value is configured as TRUE, then PTP will transmit the
originTimeStamp only through follow-up me… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.3373.1103.100.4.1.1.5 |
| ptpClockNumberPorts This indicates the number of PTP ports on the device. For an ordinary
clock this value should be 1. | column | Integer32 | .1.3.6.1.4.1.3373.1103.100.4.1.1.6 |
| ptpClockClass This object specifies the default dataset Quality Class. | column | ClockQualityClassType | .1.3.6.1.4.1.3373.1103.100.4.1.1.7 |
| ptpClockAccuracy This object specifies the default dataset Quality Accurarcy. | column | ClockQualityAccuracyType | .1.3.6.1.4.1.3373.1103.100.4.1.1.8 |
| ptpClockOffsetScaledLogVariance This value is an estimate of the variations of the local clock
from a linear timescale when it is not synchronized to another
clock using the protocol. The initialization value de… | column | Integer32 | .1.3.6.1.4.1.3373.1103.100.4.1.1.9 |