ptpClockPriority2

SIAE-PTP-MIB · .1.3.6.1.4.1.3373.1103.100.4.1.1.11

Object

column r/w Integer32
This value is used by BMC algorithm to select the best master clock.
This is used as a tiebreaker when the BMC failes to order the clock
using  ptpClockPriority1, ptpClockClass, ptpClockAccuracy and
ptpClockOffsetScaledLogVariance.
Lower values take precedence

Context

MIB
SIAE-PTP-MIB
OID
.1.3.6.1.4.1.3373.1103.100.4.1.1.11
Type
column
Access
readwrite
Status
current
Parent
ptpClockDataSetEntry
Table
ptpClockDataSetTable
Siblings
13

Syntax

Integer32

Values & Constraints

Object Constraints
range: 1-255

Related Objects

Sibling Objects