ptpClockPPSLabel
SIAE-PTP-MIB ·
.1.3.6.1.4.1.3373.1103.100.9.1.1.4
Object
column
OctetString
This object specifies the label as appears near the PPS signal socket
Context
- MIB
- SIAE-PTP-MIB
- OID
.1.3.6.1.4.1.3373.1103.100.9.1.1.4- Type
- column
- Access
- readonly
- Status
- current
- Parent
- ptpClockPPSDataSetEntry
- Table
- ptpClockPPSDataSetTable
- Siblings
- 11
Syntax
OctetString
Values & Constraints
Object Constraints
range: 0-16
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ptpClockPPSInstanceIndex This object specifies the id of PPS interface socket.
It represents the id of ToD interface socket too. | column | ClockPPSInstanceType | .1.3.6.1.4.1.3373.1103.100.9.1.1.1 |
| ptpClockToDDelay This object specifies microseconds of delay between PPS edge
and ToD data emitted, used only in output direction. | column | Unsigned32 | .1.3.6.1.4.1.3373.1103.100.9.1.1.10 |
| ptpClockToDBaudrate This object specifies the Baudrate of ToD signal in input or output direction. | column | Unsigned32 | .1.3.6.1.4.1.3373.1103.100.9.1.1.11 |
| ptpClockToDFormat This object specifies the format of ToD signal in input or output direction. | column | PtpClockToDFormatType | .1.3.6.1.4.1.3373.1103.100.9.1.1.12 |
| ptpClockPPSInstanceCapability This object is a bitmap and each bit represents
a specific capability of the PPS or ToD interface.
Bit 0 : 1 = the interface can be used either in input or in output
… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.3373.1103.100.9.1.1.2 |
| ptpClockPPSDirection This object specifies the direction (input or output)
of PPS signal and ToD data | column | Enumeration | .1.3.6.1.4.1.3373.1103.100.9.1.1.3 |
| ptpClockPPSAdminStatus This object is the administrive status of PPS interface and
specifies whether the node is enabled for PTP input/output
clocking using the PPS interface. | column | Enumeration | .1.3.6.1.4.1.3373.1103.100.9.1.1.5 |
| ptpClockPPSOffsetEnabled This object specifies whether an offset is configured
in order to compensate for a known phase error
such as network asymmetry. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.3373.1103.100.9.1.1.6 |
| ptpClockPPSOffsetValue This object specifies the fixed offset signed value in nanoseconds
configured to be added for the PPS output or input. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3373.1103.100.9.1.1.7 |
| ptpClockToDLabel This object specifies the label as appears near the ToD socket | column | OctetString | .1.3.6.1.4.1.3373.1103.100.9.1.1.8 |
| ptpClockToDAdminStatus This object is the administrive status of PPS interface and
specifies whether the ToD interface is enabled. | column | Enumeration | .1.3.6.1.4.1.3373.1103.100.9.1.1.9 |