hmtsRegMaxDuration
SCTE-HMS-HMTS-MIB ·
.1.3.6.1.4.1.5591.1.11.3.2.1.2.2.3
Object
scalar
r/w
1 s Integer32
This is the maximum time for the registration duration period. This is provided to allow a dynamic duration when a large number of TALKRQST PDUs are received during registration period. How the HMTS increases the registration duration period to this value is vendor specific. Attempt to set the maximum duration less than the minimum duration will result in a bad value error being returned. DEFAULT: vendor specific. This object is non-volatile.
Context
- MIB
- SCTE-HMS-HMTS-MIB
- OID
.1.3.6.1.4.1.5591.1.11.3.2.1.2.2.3- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- 1 s
- Parent
- hmtsRegistrationGroup
- Siblings
- 3
Syntax
1 s Integer32
Values & Constraints
Object Constraints
range: 1-255
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hmtsRegInterval This is the delay between the beginnings of each
registration period.
DEFAULT: vendor specific.
This object is non-volatile. | scalar | 1 s Integer32 | .1.3.6.1.4.1.5591.1.11.3.2.1.2.2.1 |
| hmtsRegMinDuration This is the minimum time for the registration
duration period. This is the minimum amount of time the
registration window will be open. Attempt to set minimum
duration greater … | scalar | 1 s Integer32 | .1.3.6.1.4.1.5591.1.11.3.2.1.2.2.2 |
| hmtsRegContinuity This indicates the manner that the HMTS uses to handle
processing of the TALKRQST PDU for auto discovery.
immediate - means that the HMTS immediately terminates the